58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

BioTek ELx808 Absorbance Microplate Reader with UV-Vis Detection and 4-Zone Incubation Option

UsedBioTekMicroplate readersUnited States

Price on request

In stock

Can't find what you're looking for?

Detection modes
Absorbance
Read methods
End point, kinetic, linear scanning
Microplate types
96-well plates
Temperature control
4-Zone incubation to 50 °C (+0.2 °C at 37 °C) Model Dependent
Software
Gen5 Reader Control Software
All 23 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 23

Brands
BioTek
New/Used
Used
Detection modes
Absorbance
Read methods
End point, kinetic, linear scanning
Microplate types
96-well plates
Temperature control
4-Zone incubation to 50 °C (+0.2 °C at 37 °C) Model Dependent
Software
Gen5 Reader Control Software
Light source
Tungsten halogen
Detector
photodiode
Wavelength selection
filters
Wavelength range
340 to 900 nm IU models 380 to 900 nm base model
Dynamic range
0 to 4.0 OD
Resolution
0.001 OD
Pathlength correction
no
Filter wheel capacity
6 positions
Filters supplied
4 filters (5 with UV option)
OD accuracy
< 1% at 2.5 OD < 2% at 3.5 OD
OD linearity
<1% at 2.5 OD
OD repeatability
< 0.5% at 2.5 OD < 1.5% at 3.5 OD
Reading speed (kinetic)
96 wells: 8 seconds
Power
100 – 240 Volts AC. 50/60 Hz
Dimensions
16 x 14 x 7”
Weight
20lbs

Product description

Precise BioTek ELx808 absorbance microplate reader, 96-well, 340-900 nm range, fast kinetics, Gen5 software integration.

The BioTek ELx808 Absorbance Microplate Reader is a versatile UV-Vis spectrophotometer designed for high-throughput quantification of biomolecules in 96-well microplates. It features a tungsten halogen light source and photodiode detector, covering a wavelength range of 380–900 nm on the base model and 340–900 nm on the ELx808IU variant with UV capability. This reader supports multiple read methods including end point, kinetic, and linear scanning, enabling precise kinetic ELISA assays and other quantitative absorbance measurements.

Key technical specifications include:

  • 96-well plate format compatible with standard assays in biotechnology, cell biology, molecular diagnostics, and neuroscience research.
  • Wavelength filtering via a 6-position filter wheel with up to 5 filters supplied, ensuring spectral selectivity and minimizing channel cross-talk.
  • Optical performance with dynamic range 0–4.0 OD, resolution of 0.001 OD, and high accuracy (<1% OD at 2.5, <2% at 3.5), critical for reliable bioassay quantitation.
  • A fast kinetic read speed of 8 seconds for a full 96-well plate, optimizing workflows in bioprocessing and clinical diagnostics.
  • Optional 4-zone temperature control with incubation up to 50 °C (ELx808IU model), essential for live-cell assays and controlled enzymatic reactions.
  • Onboard diagnostic self-tests and calibration via test plate to maintain instrument performance and compliance with validation protocols.
  • Integration with Gen5 Software, providing advanced data analysis tools such as transformation formulas, assay control, and validation features tailored for molecular biology and biomanufacturing processes.

Physically compact (16 x 14 x 7 inches) and lightweight (20 lbs), the ELx808 supports efficient laboratory space utilization. Its robust design minimizes edge effects and evaporation via a heated carrier, enhancing assay consistency.

Widely used in biotechnology applications including molecular cloning workflows, synthetic biology research, and biopharmaceutical production pipelines, the BioTek ELx808 is optimized for absorbance-based assays in live-cell imaging, fluorescence analysis, and clinical biomarker quantification. This microplate reader is a critical tool for researchers demanding precise, reproducible, and high-throughput absorbance measurements in diverse biomedical and agricultural domains.

Included accessories typically comprise the absorbance reader with validation reports, Gen5 software on a Windows platform, communication cables, user manual, and power cords, backed by standard warranty support.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026