Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction XRD lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

Oxford Diffraction Xcalibur PX Ultra Crystal Diffraction X-ray Generator System This system was remo (more)ved from a university lab where it was surplus to requirements. The system is in very good cosmetic condition, but several units encountered issues during testing, and no PC or control software is included. As such, the system is listed for spares/repair. - Further information regarding issues faced are stated below. The lab stated it had been not used for some time but had some issues. The system units include: - Oxford Diffraction Xcalibur PX Ultra - Serial No.: XXH-127/05 - Year: 2005 - Powered on with mains light, Shutter Closed status light, inner display screen, and hand-held remote keypad all functioning - Oxford Diffraction X-ray Protection Cabinet - Serial No.: XPD-127/05 - Year: 2005 - Thermo Scientific Neslab ThermoFlex 10,000 Recirculating Chiller - Serial No.: 1111473501170217 - Powered on but shut off after 1 second with error code "PHEr" (limit fault) - Oxford Diffraction KMW200CCD CCD Detector Chiller Unit - Serial No.: CCA 73/06 - Year: 2006 - Powered on, but no further testing possible - Oxford Diffraction KMC3000C X-ray Tube Chiller - Serial No.: CAC-142/05 - Year: 2005 - Powered on, pump ran, thermostat seemed functional, but not fully tested - Oxford Diffraction Cryodrive 2.0 - Serial No.: R72-0558 - 6944 running hours - Powered on, but no further testing without gas supply - Oxford Cryosystems Cobra Controller 700 Series Cold Head Controller - Serial No.: 741174 - Powered on, displayed ambient temperature, status lights, and responsive buttons - Parker NitroFlowLab Nitrogen Generator - Model No.: 4278 - Serial No.: 4278-13NFLC0008 - Powered on, displayed a message "writing information to an SD card," and did not allow further actions - Oxford Cryosystems Standard Cobra Nitrogen Control Pump - Serial No.: CB171 - Agilent HS 602 Vacuum Pump with NW25 Oil Exhaust Filter - Model: 849-9365R001 - Serial No.: 232830 - Year: 2006 - Produced a vacuum but failed a PAT test on insulation Additional notes: - All units passed a PAT test except for the Agilent vacuum pump, which failed due to insulation issues. - The Xcalibur unit and Neslab chiller were only visually tested due to larger power plugs. Manuals included: - Oxford Instruments Object Bench Software handbook - Xcalibur Series user manual - Thermo Scientific Recirculating Chiller Operation, Installation, and Maintenance manual - Oxford Diffraction KMC3000C user manual - Oxford Cryosystems Cobra operation guide - Safety Matters cryogenic safety manual - 2 x CrysAlis Pro user manuals - Oxford Instruments Cryojet Controller UMC002 manual - Workstation 4 VMware v4.52 Virtual Machine Software and manual Accessories included: - 1 x set of keys for safety cabinet - 1 x Long Fine Focus unit (Type OD2773/00, No. 163054) - 3 x glass vacuum traps (2 litres approx.) - 2 x vacuum pump platforms - 2 x Parker wound filter cartridges (Part No.: M11R10A) - 2 x Agilent KMW3000 filter cartridges (Part No.: IJ-00-01-002) - 1 x carbon filter nitroflow mobile - 6 x data cables - 4 x Cobra stainless steel line drier units - 1 x 4-way valve purge block - 1 x box of stainless armoured hose pipe and 1/4" plastic tubing

£4,000.00 ex VAT
United Kingdom
x ray analytical devices xrd & xrf
Zeiss Axiovert 135 TV w/ XBO 75, Prior Motorised Stage & Control Lab-cover
Zeiss Axiovert 135 TV w/ XBO 75, Prior Motorised Stage & Control Lab

Zeiss Axiovert 135 TV w/ XBO 75, Prior Motorised Stage & Control Lab This item was removed from  (more)a university lab where it was surplus to requirements. It is in good cosmetic condition and powers on successfully, with both lamps functioning. All mechanical elements operate smoothly. This microscope has been professionally serviced, the full service report is available on request. No objectives are included. Microscope Components:- Carl Zeiss Axio 3Fl Filter Slider - Filters: HQ, GFO, LP, BP 340, BP 380, FT 425, 500-530, FITC LP - Zeiss C-mount Camera Adapter (Model: 45 61 05) - Zeiss Phase Contrast Nomarski DIC LD Condenser (Model: 45 17 59) - Eyepieces: 2 x E-Pl 10x/20 - Zeiss HAL Lamp House (Model: 44 72 17) - Zeiss Illuminator Lamp House (Model: 44 72 16) Included Accessories and Additional Components: Prior ProScan III- Model: V31XYZ - Serial#: 79693 Prior Control Panel (Joystick)- Model: PS3J100 - Serial#: 80723 Prior Motorised Stage- Model: HK07X135 - Serial#: 1991 - Status: All items successfully communicate, with displays and LEDs fully functional. Includes motorised stage control via joystick, filter switching, and focus control. Does not feature a slide holder. Zeiss XBO 75 Lamp Power Supply- Model: J0470X - Serial#: 1626 - Status: Fully operational with correct cables for microscope connection. The hour clock was reset, showing only 30 minutes of use. Marzhauser Wetzlar Stage- Model: EK 130x85 Axiovert 200 - Serial#: 15042931 - Status: Non-motorized stage.

£4,000.00 ex VAT
United Kingdom
microscope accessories
Zeiss LSM 510 Meta Confocal High Resolution Microscope - Spares / Repairs Lab
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Zeiss LSM 510 Meta Confocal High Resolution Microscope - Spares / Repairs Lab NOTE - THIS IS A SPARES/REPAIRS ITEM

This Zeiss LSM 510 Meta Confocal High Resolution Microscope System was removed from a university lab (more) as it developed a fault. The university reported: "We have a confocal microscope (Zeiss LSM510 Meta) which we are hoping to sell. It powers up but doesn’t fully work, there must be a loose connection somewhere but I don’t have the time or space to work out where." The units are all generally in reasonable used cosmetic condition. All parts do power up individually but we could not get the system to run either. We believe there should be a PC containing software that we do not have. The system is sold for spares/repairs. The system consists of: 1 x Zeiss Axiovert 200M Microscope (1312-732)Fitted with:1 x Zeiss 1269-455 Dual Illumination Source Motorised Mirror Switch.1 x Zeiss 1058-431 Transmitted Light Channel LSM/Pascal.2 x Zeiss 1016-758 W-PI 10x /23 eyepieces.1 x HBO 100 Lamp 098.0042.000 (01/03163).1 x HAL 100 Lamp 42 30 00.With EBQ 100 Isolated Lamp PSU. 1 x Zeiss Laser Module 1294-260.Two of the wheels are broken, so they have all been removed and it has been put on a pallet. 1 x Zeiss LSM510 Meta System.Release 3.5 META 1305-593.With Zeiss Remote 1260-157. 1 x Microscope isolation table. Measures: 150cm L x 80cm W x 77cm H. 1 x Zeiss Temperature Control - 37 (0115.000). 1 x Zeiss AIM-SYSTEM Interface box 2436000101.

£4,185.00 ex VAT
United Kingdom
microscopes
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]