Excitation Wavelength Range
470–670 nm
Number of Simultaneous Excitation Lines
Up to 8
Frame Rate (Resonant Scanner)
Up to 428 frames per second
Scan Field
22 mm diagonal
Scan Format
8192 x 8192 pixels
Availability
Procurable
Lead time
Confirmed with your quote
All 34 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 34

Brands
Leica
New/Used
Used
Excitation Wavelength Range
470–670 nm
Number of Simultaneous Excitation Lines
Up to 8
Frame Rate (Resonant Scanner)
Up to 428 frames per second
Scan Field
22 mm diagonal
Scan Format
8192 x 8192 pixels
Pixel Size
6.5 µm
Maximum Pixel Format
2048 x 2048 pixels
Maximum Frame Rate (PCO Camera)
Up to 66 frames per second at 2048 x 2048 pixels in xyt format
Maximum Frame Rate (ORCA Flash 4 Camera)
Up to 60 frames per second at 2048 x 2048 pixels in xyt format
Maximum Write Speed (SSD RAID)
Up to 880 MB/s
Maximum Write Speed (HDD RAID)
Up to 820 MB/s
Operating Temperature Range
20–40°C
Operating Humidity Range
20–60% relative humidity (non-condensing)
Operating Pressure Limit
Up to 2000 m above sea level
Pollution Degree
2
Permitted Relative Humidity
20–60% (non-condensing)
Maximum Location Elevation
2000 m above sea level
Power Supply
100–240 V~, 50/60 Hz, grounded
Power Consumption (Flexible Supply Unit)
2 x 1600 VA
Power Consumption (Central Supply Unit)
700 VA
Heat Load (Visible Light)
1.7 kW
Heat Load (Infrared Light)
2.0 kW
Heat Load (Ultraviolet Light)
0.5 kW
Electrical Supply Voltage
100–240 V~, 50/60 Hz, grounded
Electrical Fuse (Central Supply Unit)
2 x T8AH, 250 V AC
Protection Class
Type of protection: Covered design; Overvoltage category: II
Sample Mounting
Standard glass bottom dishes with cover slip thickness of 170 ± 20 µm
Sample Elevation
Approximately 500 µm from cover slip
Light Sheet Thickness
3.6–10 µm
Weight of Basic System
Up to 330 kg
Availability
Procurable
Lead time
Confirmed with your quote

Product description

Confocal microscope with white light laser (470-670 nm), acousto-optical beam splitter, and hybrid detectors for flexible fluorescence imaging.

The Leica TCS SP8 X is an advanced confocal laser scanning microscope designed to deliver unparalleled flexibility and precision in fluorescence imaging. Equipped with a white light laser (WLL), this instrument offers complete spectral freedom, enabling researchers to select optimal excitation wavelengths for virtually any fluorophore, thereby minimising cross-excitation and specimen damage.

Key features:

  • White Light Laser (WLL): Provides tunable excitation from 470 to 670 nm, accommodating a broad range of fluorophores.
  • Acousto-Optical Beam Splitter (AOBS): Allows rapid and flexible selection of excitation and emission wavelengths without the need for manual filter changes.
  • Hybrid Detectors (HyD): Combines the benefits of photomultiplier tubes and avalanche photodiodes, offering high sensitivity and low noise for superior image quality.
  • Resonant Scanner: Enables high-speed imaging, capturing dynamic processes with frame rates up to 428 frames per second.
  • Live Cell Imaging Capabilities: Features low laser power and high sensitivity, preserving cell viability during extended imaging sessions.

This system is widely utilised in various scientific fields, including cell biology, neuroscience, developmental biology, and biomedical research. It is commonly found in university laboratories, biomedical research centres, and clinical research facilities. Introduced in 2012, the Leica TCS SP8 X remains a relevant and powerful tool in contemporary research settings.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 27 October 2026