Varian Mercury 300

UsedVarianMolecular imaging devicesNetherlands
Procurable

Not in stock, available to order through our sourcing team

Not in stock, but we can get it for you

We source this model through our supplier network. Request a quote and we'll come back within one hour.

  1. Request a quote
  2. We confirm price and lead time
  3. You approve, we ship to you
Magnet Field Strength
7.0 T
Pulsed Field Gradient Strength
10 G/cm
RF System Channels
2
RF System Amplifier Power (1H)
75 W
RF System Amplifier Power (X Channel)
150 W
Availability
Procurable
Lead time
Confirmed with your quote
All 41 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 41

Brands
Varian
New/Used
Used
Magnet Field Strength
7.0 T
Pulsed Field Gradient Strength
10 G/cm
RF System Channels
2
RF System Amplifier Power (1H)
75 W
RF System Amplifier Power (X Channel)
150 W
Pulse Shaping
Linear modulator
Magnet Type
Unshielded
Magnet Manufacturer
Oxford
Magnet Bore Diameter
54 mm
Magnet Hold Time
80 days
Temperature Range
-80°C to +130°C
Temperature Control Precision
0.1°C
Probe Type
5-mm ATB (Automation Triple Resonance Broadband)
Probe Channels
1H, 19F, 13C, 31P
Sample Changer
Automatic
Sample Changer Capacity
Not specified
Sample Changer Compatibility
High-volume laboratories
Sample Changer Automation
Automated sample handling
Sample Changer Throughput
Enhanced throughput
Sample Changer Application
High-volume laboratories
Sample Changer Functionality
Facilitates automated sample handling
Sample Changer Ideal Use
High-volume laboratories
Sample Changer Feature
Enhances throughput by facilitating automated sample handling
Sample Changer Description
Enhances throughput by facilitating automated sample handling, ideal for high-volume laboratories
Sample Changer Benefit
Ideal for high-volume laboratories
Sample Changer Advantage
Enhances throughput by facilitating automated sample handling
Sample Changer Function
Facilitates automated sample handling
Sample Changer Purpose
Enhances throughput by facilitating automated sample handling
Sample Changer Use
Ideal for high-volume laboratories
Acquisition Computer Processor
Motorola 68040
Acquisition Computer Operating System
VxWorks
Acquisition Computer ADC Resolution
16-bit
Acquisition Computer ADC Sampling Rate
100 kHz
Host Workstation Processor
Sun Ultra-5, 400-MHz
Host Workstation Operating System
Solaris 8
Software
VNMR 6.1C
Acquisition Computer Interface
Ethernet TCP/IP
Availability
Procurable
Lead time
Confirmed with your quote

Product description

High-resolution 300 MHz NMR with multi-nucleus detection, variable temperature, pulsed field gradients, and automated sample handling.

The Varian 300 MHz NMR spectrometer is a versatile instrument designed for high-resolution nuclear magnetic resonance (NMR) spectroscopy, essential in molecular structure elucidation and dynamic studies. This spectrometer is widely employed in various scientific disciplines, including biotechnology, molecular biology, and organic chemistry, facilitating research in areas such as protein structure analysis, metabolomics, and drug discovery.

Key features:

  • Multi-nucleus capability: Supports detection of multiple nuclei, including ¹H, ¹³C, ³¹P, and ¹⁹F, enabling comprehensive molecular analysis.
  • Variable temperature control: Allows experiments across a broad temperature range, accommodating studies of temperature-sensitive samples.
  • Automatic sample changer: Enhances throughput by facilitating automated sample handling, ideal for high-volume laboratories.
  • Pulsed field gradients (PFG): Improves spectral resolution and enables advanced NMR techniques, such as diffusion-ordered spectroscopy (DOSY).
  • Broadband probes: Accommodate a wide range of nuclei, providing flexibility for diverse experimental needs.

Commonly utilized in university laboratories, biomedical research centres, and pharmaceutical companies, this spectrometer supports a range of applications:

  • Structural elucidation: Determining the three-dimensional structures of biomolecules, crucial in protein engineering and synthetic biology.
  • Metabolomics: Profiling metabolites in biological systems, aiding in bioprocessing and molecular diagnostics.
  • Quality control: Assessing the purity and composition of compounds in biomanufacturing and pharmaceutical development.

Introduced in the mid-1990s, the Varian 300 MHz NMR spectrometer remains in use today, reflecting its enduring reliability and adaptability in the evolving field of biotechnology.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 16 November 2026