58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

VACUUBRAND DVR 2pro Vacuum Gauge

NewVacuubrandVacuum gaugesUnited States

€1,009.49excl. VAT

In stock

Can't find what you're looking for?

Upper measuring limit in mbar/hPa
1060 mbar
Upper measuring limit in torr
795 torr
Lower measuring limit in mbar/hPa
1
Lower measuring limit in torr
1 torr
Measurement principle
Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
All 29 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 29

Brands
Vacuubrand
New/Used
New
Upper measuring limit in mbar/hPa
1060 mbar
Upper measuring limit in torr
795 torr
Lower measuring limit in mbar/hPa
1
Lower measuring limit in torr
1 torr
Measurement principle
Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement
< +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Temperature coefficient
< 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection
Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage)
-10 °C
Upper ambient temperature (storage)
60 °C
Lower ambient temperature (operation)
10 °C
Upper ambient temperature (operation)
40 °C
Max. media temperature for continuous operation
40 °C
Max. media temperature short term
80 °C
Automatic switch-off
User-selectable: 1-600 min (default 5 min) or continuous operation min
Measurement cycle
User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s
Material of outer housing
Robust plastic housing with good chemical resistance
Protection class IEC 60529
IP 40
Power supply
9 V battery
Weight
0.4 kg
Dimension L in mm
115 mm
Dimension B in mm
115 mm
Dimension H in mm
90 mm
Vacuum sensor
Integr.
Typical battery lifetime
4.000 h, stand-by: 30.000 h h
NRTL certification
No
Items supplied
Vacuum gauge complete with integrated vacuum sensor, including battery 9 V alkali-manganese, support rod, connecting parts and manual.

Product description

Precision vacuum gauge with improved functionality and chemical resistance for versatile laboratory use.

VACUUBRAND DVR 2pro Vacuum Gauge

Upper Measuring Limit 1060 mbar/hPa (795 torr) Lower Measuring Limit 1 mbar/hPa (1 torr) Vacuum Sensors Integrated

Features

  • Improved functionality within the navigation menu helps to save energy and to increase the life cycle of the battery
  • Large, graphical analog display with digital measuring values alows to detect tendencies and makes it easier to readout precisely
  • Pressure unit user-selectable in mbar, hPa or Torr prevents unnecessary conversions
  • Different vacuum connections and the additional support rod allow the use in almost every laboratory application
  • Chemical resistant materials for wetted parts together with the capacitive ceramic diaphragm pressure sensor provide excellent long-term stability and accuracy

The DVR 2pro is a fully electronic, versatile vacuum gauge for the measuring range from atmospheric pressure to 1 mbar. All wetted parts are made from enhanced chemical resistant material which allows the use under very rough laboratory conditions. The high accuracy and the large graphical display from the DVR 2 have also been carried forward for the “pro” version. One of the main enhancements is the power supply with a normal 9 V Alkaline battery. The new battery slot at the back of the gauge allows for easy replacement of the battery. A wider range of connection parts provide a great range of connection flexibility for laboratory use.INCLUDED: The VACUUBRAND DVR 2pro Vacuum Gauge includes:

  • 9V Alkali-Manganese Battery
  • Support Rod and Connecting Parts
  • Operator's Manual
  • Manufacturer's Documentation
  • 2 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026