Gel Dimensions (W x L)
15 x 15 cm
Maximum Buffer Volume
1.2 L
Maximum Power Settings
300 V, 200 mA, 60 W
Maximum Sample Capacity
120
Maximum Running Temperature
45°C
All 11 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 11

Brands
Hoefer
New/Used
New
Gel Dimensions (W x L)
15 x 15 cm
Maximum Buffer Volume
1.2 L
Maximum Power Settings
300 V, 200 mA, 60 W
Maximum Sample Capacity
120
Maximum Running Temperature
45°C
Indoor Use
4 to 40°C
Humidity
Up to 80%
Unit Dimensions (W x L x H)
8.5 x 13.2 x 2.8 in. (21.5 x 33.5 x 7 cm)
Unit Weight
6.5 lb. (2.94 kg)

Product description

Efficient DNA analysis with 120-sample capacity, ideal for high-throughput labs.

Hoefer SUBHT High Throughput Submarine Gel Electrophoresis Unit

Gel Dimensions (W x L) 15 x 15 cm Maximum Power Settings 300 V, 200 mA, 60 W Maximum Buffer Volume 1.2 L

Features

  • Fast, error-free loading—Load an entire 96-well plate using a multichannel pipette
  • Simplified analysis—Fluorescent labels for each sample printed on a UV transparent gel tray allows for instant sample identification (matched to a 96-well plate) during post-run visualization
  • High throughput—Run up to 120 samples (96-well plate + 24 control and/or marker samples) in 30 minutes
  • Better reproducibility—Eliminate variability caused by running buffer pH drift and ionic gradient formation with optional buffer recirculation capability
  • Reduced buffer needs—Compact tank design needs less buffer to cover gel which not only reduces buffer consumption but provides greater control of voltage gradients and run times
  • Maximum flexibility—Fully compatible with a wide range of combs and accessories to meet all your high throughput and standard gel analysis needs

The Hoefer SUBHT High Throughput Submarine Gel Electrophoresis Unit is designed for efficient, large-scale DNA screening applications, such as single strand polymorphism (SSP) analysis following PCR. This versatile unit can resolve DNA fragments ranging from 50 to 1000 base pairs in as little as 30 minutes, accommodating up to 120 samples, making it an ideal choice for labs focused on high-throughput workflows.

Engineered for precision and speed, the SUBHT allows for seamless loading of an entire 96-well plate using a multichannel pipette. The UV-transparent gel tray with fluorescent labels matches the 96-well plate layout, enabling instant sample identification during post-run visualization. Compact and efficient, the SUBHT minimizes buffer consumption while ensuring consistent voltage gradients and reproducible results. With optional buffer recirculation ports to maintain pH stability, this unit provides both flexibility and reliability. It’s compatible with a range of combs and accessories, making it adaptable for various high-throughput and standard gel electrophoresis needs.

INCLUDED: The Hoefer SUBHT High Throughput Submarine Gel Electrophoresis Unit includes:

  • Buffer Chamber Assembly
  • Safety Lid
  • High Voltage Leads
  • Fluorescent Labeled Running Tray with Casting Gates
  • 1 mm thick, 30 well combs, 4 pcs
  • Colored Loading Strips
  • Buffer Recirculation Ports, 2 pcs
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 5 November 2026