53k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Hoefer SE600 Standard Dual Cooled Vertical Protein Electrophoresis Basic Unit

NewHoeferElectrophoresisUnited States

From€1,596.21excl. VAT

In stock

Can't find what you're looking for?

Glass Plate Size (W x H)
18 x 16 cm or 18 x 8 cm
Spacers
0.75 mm, 1.0 mm, 1.5 mm
Maximum Power Settings
1000 V, 500 mA, 50 W
Maximum Temperature
45°C
Indoor Use
4 to 40°C
All 10 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 10

Brands
Hoefer
New/Used
New
Glass Plate Size (W x H)
18 x 16 cm or 18 x 8 cm
Spacers
0.75 mm, 1.0 mm, 1.5 mm
Maximum Power Settings
1000 V, 500 mA, 50 W
Maximum Temperature
45°C
Indoor Use
4 to 40°C
Humidity
Up to 80%
Unit Dimensions (W x H x D)
12.6 x 11.4 x 5.5 in. (32 x 29 x 14 cm)
Basic Unit Weight
15.4 lb. (7.00 kg)

Product description

High-capacity electrophoresis system with dual cooling for protein and nucleic acid analysis.

Hoefer SE600 Standard Dual Cooled Vertical Protein Electrophoresis Basic Unit

Compatible Glass Plate Sizes (W x H) 18 x 16 cm or 18 x 8 cm Maximum Power Settings 1000 V, 500 mA, 50 W Compatible Spacers 0.75 mm, 1.0 mm, 1.5 mm

Features

  • Maximum glass plate size 18 x 16 cm
  • Produce straight lanes and sharp, well defined bands
  • Run up to four gels (maximum 112 samples) at one time under identical conditions
  • Run gels at uniform temperature from 1 to 45°C
  • Accommodates denaturing and native polyacrylamide gels and 2-D electrophoresis
  • A wide array of accessories allows you to tailor gel configurations to your needs

The Hoefer SE600 Standard Dual Cooled Vertical Protein Electrophoresis Basic Unit is an efficient, high-capacity system designed for versatile protein and nucleic acid analysis. This unit accommodates glass plates up to 18 x 16 cm, making it ideal for applications requiring precise and consistent separation. With dual cooling capabilities, the SE600 maintains uniform temperatures from 1 to 45°C, ensuring sharp, well-defined bands across all samples. Its adaptable design supports both denaturing and native polyacrylamide gels, as well as 2-D electrophoresis, offering flexibility for diverse lab requirements.

Capable of running up to four gels simultaneously with a capacity for up to 112 samples, the SE600 is suited for high-throughput environments that demand reliable performance. Its range of compatible accessories allows labs to customize gel configurations based on specific needs, and its straightforward design simplifies assembly and operation. Operating effectively within standard lab conditions, it handles temperatures up to 45°C and humidity levels up to 80%, while power settings reaching 1000 V and 500 mA ensure robust performance across experimental setups.

Please note, the dropdown menu allows selection of a complete package based on preferred spacer accessory (0.75 mm, 1.0 mm, or 1.5 mm), which includes the following products:

  • Lower Buffer Chamber
  • Upper Buffer Chamber
  • Safety Lid w/High Voltage Leads
  • Heat Exchanger
  • Glass Plates 18 x 16 cm, 6 pcs
  • Clamp Assemblies, 16 cm, 4 pcs
  • Cams, 6 pcs
  • Slotted Gaskets for Upper Buffer Chamber, 2 pcs
  • Dual Gel Casting Stand with Leveling Base
  • Bubble Level
  • Laminated Gaskets for Caster, 2 pcs
  • Buffer Dam
  • Spacer-Mate Alignment Template
  • Wonder Wedge Plate Separation Tool
  • Gel Seal
  • Combs, 15-well, 1.5 mm thick, 2 pcs
  • Spacers, 1.5 mm thick, 2 cm wide, 4 pcs

INCLUDED: The Hoefer SE600 Standard Dual Cooled Vertical Protein Electrophoresis Basic Unit includes:

  • Lower Buffer Chamber
  • Upper Buffer Chamber
  • Safety Lid w/High Voltage Leads
  • Heat Exchanger
  • Glass Plates 18 x 16 cm, 6 pcs
  • Clamp Assemblies, 16 cm, 4 pcs
  • Cams, 6 pcs
  • Slotted Gaskets for Upper Buffer Chamber, 2 pcs
  • Dual Gel Casting Stand with Leveling Base
  • Bubble Level
  • Laminated Gaskets for Caster, 2 pcs
  • Buffer Dam
  • Spacer-Mate Alignment Template
  • Wonder Wedge Plate Separation Tool
  • Gel Seal
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 6 November 2026