52k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Hoefer SE900 Large Format Vertical Protein Gel Electrophoresis Basic Unit

NewHoeferElectrophoresisUnited States

From€5,222.09excl. VAT

In stock

Can't find what you're looking for?

Gel Plate Size (W x H)
28 x 21 cm
Gel Size (W x H)
25 x 20 cm
Maximum Power Settings
600 V, 1000 mA, 150 W
Maximum Temperature
45°C
Humidity
Up to 80%
All 11 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 11

Brands
Hoefer
New/Used
New
Gel Plate Size (W x H)
28 x 21 cm
Gel Size (W x H)
25 x 20 cm
Maximum Power Settings
600 V, 1000 mA, 150 W
Maximum Temperature
45°C
Humidity
Up to 80%
Buffer Pump
50,000 hour pump life
Weight
30 lb. (13.6 kg)
Unit Dimensions (W x H x D)
16.9 x 16.9 x 7.9 in. (43 x 43 x 20 cm)
Electrical Requirements
100 to 240 V, 50 to 60 Hz, 2A

Product description

High-capacity vertical electrophoresis system ideal for high-throughput protein analysis and precision separation.

Hoefer SE900 Large Format Vertical Protein Gel Electrophoresis Basic Unit

Compatible Glass Plate Sizes (W x H) 28 x 21 cm Gel Size 25 x 20 cm Maximum Power Settings 600 V, 1000 mA, 150 W

Features

  • No upper buffer chamber—no gasket issues and no risk of buffer loss
  • Utilizes minimal parts—easy to use and reliable
  • External cooling and internal buffer circulation—ensures an even,constant, and uniform temperature for reproducible results
  • Up to six 28 cm plates can be run at one time—perfect for high throughput applications
  • Glass plate sandwiches are hinged cassettes—allows for rapid and easy assembly before use
  • Built-in draining port—avoids lifting of a heavy buffer-filled tank
  • Assembly of the tank is easy—no clamps needed Innovative design enables re-use of tank buffer
  • Innovative design enables re-use of tank buffer—decreased buffer consumption for reduced cost

The Hoefer SE900 Large Format Vertical Protein Gel Electrophoresis Basic Unit is a specialized, high-capacity system designed for second-dimension electrophoretic separation. Ideal for high-throughput applications, this unit can accommodate up to six 28 cm SDS-PAGE gels at once, making it perfect for labs that need reliable, large-scale protein analysis. Its adaptable design also accommodates similar-sized plates from other manufacturers, offering flexibility for various lab setups. Built for precision, the SE900 features external cooling and internal buffer circulation to maintain a constant and uniform temperature, ensuring reproducible results with each run.

This unit’s innovative design minimizes maintenance with no upper buffer chamber, eliminating gasket issues and buffer loss risk. It’s engineered for ease of use, with hinged glass plate cassettes for quick assembly and a built-in draining port to avoid lifting a heavy buffer-filled tank. Simplified with minimal parts, this electrophoresis system is easy to assemble and maintain. Operating smoothly within standard lab conditions, the SE900 can handle temperatures up to 45°C and humidity up to 80%, with power settings reaching up to 600 V, 1000 mA, and 150 W.

Please note, the dropdown menu allows selection of a complete package, which includes:

  • Separation Tank
  • Tubing Kit
  • Lid with High Voltage Leads
  • Multiple Gel Caster
  • Internal PAGE Rack
  • Hinged Glass Cassettes-6 pcs

INCLUDED: The Hoefer SE900 Large Format Vertical Protein Gel Electrophoresis Basic Unit includes:

  • Separation Tank
  • Tubing Kit
  • Lid with High Voltage Leads
  • Internal PAGE Rack
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 8 November 2026