Gel Dimensions (W x L)
4.9 x 5.1 in. (12.5 x 13.0 cm)
Maximum Sample Capacity
112 samples (4 combs, 28 samples each)
Buffer Capacity
350 ml
Distance Between Electrodes
5.3 in. (13.5 cm)
Unit Weight
3.6 lb. (1.65 kg)
All 19 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 19

Brands
Hoefer
New/Used
New
Gel Dimensions (W x L)
4.9 x 5.1 in. (12.5 x 13.0 cm)
Maximum Sample Capacity
112 samples (4 combs, 28 samples each)
Buffer Capacity
350 ml
Distance Between Electrodes
5.3 in. (13.5 cm)
Unit Weight
3.6 lb. (1.65 kg)
Unit Dimensions (W x L x H)
9.6 x 6.7 x 2.4 in. (24.5 x 17.0 x 6.2 cm)
Material Characteristic
UV transmitting (50% at 254 nm, 80% at 312 nm)
Solution Volume
350 ml
Overall Dimensions (W x L x H)
7.2 x 6.5 x 2.2 in. (18.3 x 16.4 x 5.6 cm)
Output Voltage
10 to 150 volts; constant peak voltage of 150 V
Output Amperage
10 to 400 mA
Maximum Wattage
45 W
Timer
99 hours 59 min, or continuous run
Safety Switch
A microsensor in the power supply prevents output without the safety lid in place
Memory Function
Automatic memory (the last used Voltage & Time)
Weight
0.9 lb. (410 g)
Electrical Requirements
115V, 50/60Hz

Product description

Compact electrophoresis system with built-in power supply for efficient nucleic acid separation.

Hoefer HE-PLUS Horizontal Nucleic Acid Electrophoresis System

Gel Dimensions (W x L) 12.5 x 13.0 cm Maximum Sample Capacity 112 samples (4 combs, 28 samples each) Max. Power Settings 150 volts, 400 mA, and 45 watts

Features

  • Compact and Easy to Use
  • Built-in Variable Power Supply with LED Display
  • Adjustable Power Supply from10 to 400 mA or 10 to 150 Volts
  • Built-in Timer with Audible Alert
  • Supports multichannel pipette-compatible combs for efficient loading and increased sample capacity
  • Durable construction with UV-transmitting material
  • Vented lid reduces condensation buildup
  • Automatically recalls the last-used voltage and time for faster setup on repeat runs

The Hoefer HE-PLUS Horizontal Nucleic Acid Electrophoresis System is a compact, user-friendly solution for high-throughput nucleic acid separation. Featuring a built-in variable power supply with an LED display, this system provides clear visibility of voltage, amperage, and time, allowing precise control over every run. With an adjustable power range of 10 to 400 mA or 10 to 150 volts, the HE-PLUS is versatile enough for a wide range of applications. The integrated timer with a 99-hour, 59-minute limit and audible alert ensures efficient workflow management.

Designed for high efficiency, the HE-PLUS supports a 96-well format compatible with multichannel pipettes, making sample loading fast and accurate. Its durable polycarbonate tank and UV-transmitting construction allow clear monitoring throughout the run, while a vented lid reduces condensation. Safety is prioritized with a microsensor that prevents operation without the safety lid in place. Additional features like the memory function for last-used settings make it easy to set up repeat runs, ensuring consistent results with minimal prep time.

INCLUDED: The Hoefer HE-PLUS Horizontal Nucleic Acid Electrophoresis System includes:

  • Gel tank
  • Safety lid
  • Power supply
  • Large gel tray
  • Medium gel trays, 2 pieces
  • Large/medium comb 14/28 wells, 4 pieces
  • Casting stand
  • Power Cord
  • Operator's Guide
  • Manufacturer's Documentation
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 16 November 2026