Power Supply
2200 VA max
Voltage
220 V
Temperature Range
4 to 450 °C
Temperature Programming Rates
0.1 to 70 °C per min
Oven Run Time
650 min maximum
Availability
Procurable
Lead time
Confirmed with your quote
All 37 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 37

Brands
Agilent
New/Used
Used
Dimensions
1300 x 1180 x 1190 mm
Weight
45.4 kg
Power Supply
2200 VA max
Voltage
220 V
Temperature Range
4 to 450 °C
Temperature Programming Rates
0.1 to 70 °C per min
Oven Run Time
650 min maximum
Column Oven Temperature Range
4 to 450 °C
Column Oven Temperature Programming Rates
0.1 to 70 °C per min
Column Oven Run Time
650 min maximum
Column Oven Setpoint Entry
1 °C for temperatures, 0.1 °C for program rates
Column Oven Programming
Three ramps with initial/final holds
Heated Zones
Five heated zones standard: Two detectors, Two inlets, one auxiliary
Methods Stored
Two
Split/Splitless Capillary Inlet Temperature Range
Up to 400 °C in 1 °C increments
Split/Splitless Capillary Inlet Back-Pressure Design
Permits independent adjustment of split flow rate without affecting column flow
Split/Splitless Capillary Inlet Septum Purge
Built-in at 3 ml/min
Flame Ionization Detector (FID) Temperature Range
Up to 450 °C
Thermal Conductivity Detector (TCD) Temperature Range
Up to 400 °C
Inlet Options
Five inlet choices, including split/splitless and packed inlets
Carrier Gas Flow Rate for Capillary Columns
45 ml/min
Carrier Gas Flow Rate for Packed Columns
50 ml/min
Split Flow Rate for Capillary Columns
45 ml/min
Split Flow Rate for Packed Columns
50 ml/min
Septum Purge Flow Rate
3 ml/min
Split/Splitless Capillary Inlet Column Acceptance
Accepts columns up to 1.2-mm OD
Split/Splitless Capillary Inlet Multimode Design
Includes split and splitless injection
Split/Splitless Capillary Inlet Splitless Purge Time
Variable in 0.01-min increments
Detector Options
Six detector options, such as Flame Ionisation Detector (FID) and Thermal Conductivity Detector (TCD)
Flame Ionization Detector (FID) Sensitivity
18 mCoul/gm carbon: nitrogen carrier, 0.018-in. ID jet
Flame Ionization Detector (FID) Minimum Detectable
<5 pg carbon/sec, nitrogen carrier at S/N=2
Flame Ionization Detector (FID) Linear Dynamic Range
<+/- 10% over a 10^7 range with 0.018-in. ID jet
Thermal Conductivity Detector (TCD) Minimum Detectable
400 pg/ml carrier — equivalent to 1 ppm neon in 1 ml air
Availability
Procurable
Lead time
Confirmed with your quote

Product description

Analytical GC with EPC, multi-inlet/detector options, advanced temp programming, digital interface for precise mixture analysis.

Hewlett Packard 5890 Series II Gas Chromatograph

The Hewlett Packard 5890 Series II Gas Chromatograph is a robust analytical instrument designed for the precise separation and analysis of complex chemical mixtures. Utilising a narrow, flow-through column, this gas chromatograph enables the identification and quantification of individual components within a sample, making it indispensable in various scientific and industrial applications.

Key features:

  • Versatile inlet and detector options:
  • Five inlet choices, including split/splitless and packed inlets.
  • Six detector options, such as Flame Ionisation Detector (FID) and Thermal Conductivity Detector (TCD).
  • Electronic Pressure Control (EPC):
  • Enhances precision and reproducibility in analyses.
  • Advanced temperature programming:
  • Three-ramp oven temperature programming for optimal separation.
  • User-friendly interface:
  • Digital display with time-table operation and diagnostic functions.
  • Compatibility with data analysis software:
  • Seamless integration with Agilent ChemStation for comprehensive data handling.

Applications:

  • Biotechnology:
  • Essential for molecular diagnostics and bioprocessing workflows.
  • Pharmaceutical research:
  • Critical in drug development and quality control processes.
  • Environmental analysis:
  • Widely used for detecting pollutants and ensuring regulatory compliance.
  • Food safety:
  • Instrumental in analysing contaminants and ensuring product quality.
  • Forensic science:
  • Utilised in the identification of substances in criminal investigations.

Commonly used in:

  • University laboratories
  • Biotechnology firms
  • Pharmaceutical companies
  • Environmental agencies
  • Food and beverage industries

First introduced in 1984, the HP 5890 Series II has established itself as a gold standard in gas chromatography. Its enduring reliability and versatility have ensured its continued use in laboratories worldwide, even as newer models have emerged.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 3 November 2026