Agilent J&W DB-1 capillary gas chromatography column with 15 m length, 0.32 mm ID, 0.10 µm film and 100% PDMS phase.
The Agilent J&W DB-1 capillary gas chromatography column is a nonpolar GC column for general purpose analytical separations.
The column uses a bonded, crosslinked 100% dimethylpolysiloxane phase and is supplied in a 7 inch cage. It is compatible with Agilent 5890, 6890, 7820, 7890, 8860 and 8890 series gas chromatographs, as well as non Agilent systems with a similarly sized oven.
The column is offered in used condition.
This used Agilent J&W DB-1 gas chromatography column has a 100% dimethylpolysiloxane stationary phase for nonpolar, general purpose GC separations.
The column is compatible with Agilent 5890, 6890, 7820, 7890, 8860 and 8890 series gas chromatographs. It also fits non Agilent gas chromatographs with a similarly sized oven. Similar phases include SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1 and MDN-1.
The 100% dimethylpolysiloxane stationary phase places the column in the nonpolar DB-1 class and supports general purpose gas chromatography. The bonded and crosslinked phase is solvent rinsable and is described as low bleed with a high temperature limit.
The DB-1 phase is equivalent to USP Phase G2. Similar phases include SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1 and MDN-1. These designations support method and replacement-column matching across comparable phase families.
Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.
We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.
We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.
With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.
Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.
Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.
Two to six weeks, depending on refurbishment scope and whether calibration is included.
We ship to 38 countries. Crating and customs handling are quoted with the instrument.