Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System Spares/Repairs
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

This GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System was removed from a university (more) lab where it was surplus to requirements. The microscope focus motor/Z-Drive has been removed from this unit. We have removed the microscope focus motor/Z-Drive from this system. It is sold for spares/repairs. Included in the system are; 1x GE IN Cell Analyzer 1000: Dims: L85cm W70cm H70cmThe unit is in good cosmetic condition. When connected up to the power supply we could not hear the unit power on.Inside the unit it appears have been tampered with as there are several cables and connector cables not attached to anything the EARTH cable is also not attached. A circuit board has been removed from the unit. this may explain why we could not get the unit powered up. 1x GE IN Cell Analyser 1000 Kinetic OZ EnabledModel No. 28-4051-29System No. 1316043The unit powers on and is in good cosmetic condition.The fans are working, they can be heard powering up immediately once the unit is powered on. 1x GE IN Cell Analyser 1000 ENDPNT OZ EnabledModel No. 28-4051-28System No. 1358008The unit powers on and is in good cosmetic condition. The unit appears to have been stripped only 1x HP Workstation 6200 PC and 1x MVP Series power supply were still inside it. The Kinetic OZ Enabled unit appears to be complete with an Optigrid light imaging system. We have fitted the GE IN Cell Power supply back into the rack unit where it should be housed. EMKA Keys:Model 2233X2x keys for GE IN Cell Analyser 1000 ENDPNT OZ Enabled2x keys for the GE IN Cell Analyser Kinetic OZ EnabledAll 4 keys are in good cosmetic condition and open and lock both the Kinetic and the ENDPNT units. We did not connect up the GE IN Cell 1000 to the GE 1000 Kinetic OZ Enabled unit as one of the communication cable connections at the back of the rack has come away and will need to be fixed back on. Without this being fixed we do not believe the systems to be aware of each other. 1x Optigrid Light Imaging System:Model QIOPTIQThe unit powers on and is in good cosmetic condition. 1x Xenon ARC Lamp Power supply w 2x keys:Type 6Part No. 56409187The unit powers on and is in good cosmetic condition. The keys do not fit in the barrel well and do not turn. The LCD screen is working and reads clearly. Keys:model No. 901The units are in good cosmetic condition 2x MVP Series Power supplies. ( 1x in each rack unit)Model Nos. MP8-3Q-1L-00Both units power on and are in good cosmetic condition. There is dust around and on both units from general use. 1x Hamilton power supplyModel No. 231352/00The unit powered on and is in good cosmetic condition. 2x APC rack PDUThe units power on and are in good cosmetic condition. 1x GE cO2 Controller:Ser No. 1352436The unit powers on and is in good cosmetic condition. The LCD screen is working and reads clearly. All dials and switches appear responsive to the unit. 2x Hewlett Packard PC's: HP workstation xw6200:The units both power on and are in good cosmetic condition.There is some dust around the units from general use. Programs on PC:•Overlord 2Version 2.1.0.0 •IN Cell Analyser 1000 3.5•IN Cell Analyser 1000 3.6The program is password protected and we could not get past this window to access other parts of the program. 'Shutter Counter 1984048'. 3 x Low Voltage Computer Cables:•28-4060-63 Umbellcal Axis 0734•28-4060-66 0647•28-4060-68 Umbellcal Hamilton 0738 1x Xenon lamp Bulb:Model OSRAM XBO 100W OFRThe box had been opened. We cannot confirm if this lamp has been used. The unit was in good cosmetic condition.

£3,015.00 ex VAT
United Kingdom
flow cytometers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]