Circulation Method
Forced air circulation
Operating Temperature Range
Room temp. +10~260°C
Temp. Control Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
90min (at room temp. +10°C~260°C)
All 32 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 32

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced air circulation
Operating Temperature Range
Room temp. +10~260°C
Temp. Control Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
90min (at room temp. +10°C~260°C)
Interior Material
Stainless Steel
Exterior Material
Cold rolled steel plate with melamine resin baking finish
Heat Insulating Material
Glass wool
Heater
SUS pipe heater / 1.34kW
Fan Type / Motor
Scirocco fan / Condenser type motor 10W
Cable Port
30 mm l.D.×1 pc. (right side)
Exhaust Port
30 mm l.D.×2 pcs. (the top)
Temp. Controller
PlD control by microprocessor
Temp. Setting Method
Operation menu key and digital setting by ▲/▼ key
Temp Display Method Measurement temp.
Digital display by green LED / Setting temp. : Digital display by red LED
Timer
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. (with time wait function)
Operation Functions
Fixed temperature operation, Quick Auto-stop, Auto start, Auto stop
Additional Functions
Calibration off-set function, Key lock, Uninterruptible power for memory
Heater Circuit Control
SSR control
Sensor
K-thermocouple
Safety Device
Self diagnostic functions (Sensor trouble detection, Memory error, Measured temperature lower limit error, Measured temperature error), Auto overheat prevention, Independent overheat prevention.
Internal Dimensions W×D×H
600×500×500mm
External Dimensions W×D×H
710×651×870mm
Internal Capacity
150L
Shelf Plate With Standard Load
15kg/piece
Shelf Rest Step Number
12 steps
Shelf Rest Pitch
35mm
Power Source 50/60Hz
AC115V 12A
Weight
65kg
Shelf Plate / Bracket
Stainless steel 2 pcs. / 4 pcs.

Product description

Forced air convection oven with 150L capacity, digital PID control, 10–260°C range, and safety features.

Yamato DKM600C Forced Air Convection Oven – 150 Liters (5.3 Cu Ft.)

  • Operating Modes: Fixed temperature, Quick Auto stop, Auto stop, Auto start
  • Temperature Control: Digital PID control via microprocessor, with ▲/▼ key setting and operation menu keys
  • Temperature Range: Room temperature +10°C to 260°C
  • Control Accuracy: ±1°C (at 210°C)
  • Temperature Distribution Accuracy: ±2.5°C (at 210°C)
  • Max. Temperature Reaching Time: 90 minutes (from room temp. +10°C to 260°C)
  • Interior Material: Stainless steel
  • Exterior Material: Cold rolled steel plate with melamine resin baking finish
  • Heat Insulation: Glass wool
  • Heater: SUS pipe heater, 1.34 kW, SSR controlled
  • Circulation: Forced air by Scirocco fan driven by 10W condenser type motor
  • Ports: One 30 mm inner diameter cable port (right side), two 30 mm inner diameter exhaust ports (top)
  • Temperature Display: Green LED for measurement, red LED for setting
  • Timer: 1 min to 99 hr 59 min and 100 hr to 999 hr 50 min with time wait function
  • Additional Functions: Auto recovery after power failure, calibration offset, key-lock, uninterruptible power for memory
  • Safety Features: Self-diagnostic functions (sensor trouble detection, memory error, measured temperature errors), auto and independent overheat prevention
  • Dimensions (W×D×H): Internal 600×500×500 mm, External 710×651×870 mm
  • Capacity: 150 liters
  • Shelves: 2 stainless steel shelf plates included, 15 kg load capacity per shelf, 12-step shelf rest pitch at 35 mm intervals
  • Power Source: AC 115 V, 12 A, 50/60 Hz
  • Weight: 65 kg

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.