53k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Yamato DNE-611 Programmable Forced Convection Oven 150L, 220V

From€5,397.03excl. VAT

In stock

Can't find what you're looking for?

Circulation Method
Forced air circulation
External Temp. Range
5~35°C
Operating Temp. Range
RT+20°C to 210°C
Temp. Control Accuracy*¹
±0.5°C (at 210°C)
Temp. Distribution Accuracy*¹
±2.0°C (at 210°C)
All 35 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 35

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced air circulation
External Temp. Range
5~35°C
Operating Temp. Range
RT+20°C to 210°C
Temp. Control Accuracy*¹
±0.5°C (at 210°C)
Temp. Distribution Accuracy*¹
±2.0°C (at 210°C)
Temp. Gradient*¹
8°C (at 210°C)
Temp. Rise Time*¹
~70 min.
Chamber / Exterior / Insulation
Stainless steel / Chrome-free electro-galvanized steel plate, chemical-proof baked-on finish / Glass wool
Door
Single swing (left side)
Fan Type
Scirocco fan, Capacitor motor
Fan Motor
10W
Exhaust Port
33mm I.D. 2pcs. (top)
Observation Window
Optional
Temp. Controller
PID Z control by microprocessor
Temp. Setting Method
Digital setting by ▲/▼ key
Temp. / Info Display
Green 4 digit LED digital display (top screen) and orange 5 digit LED digital display (bottom screen) (1°C resolution)
Timer
1 min. and 99 Hrs. 59 mins: duration operation, 24 hour setting: time operation
Operation Function
Fixed temperature, Program operation (max.99 steps, up to 99 patterns repeat operationing function), Duration/time select timer operationfunction (fixed temperature operation, auto-start, auto-stop, quick auto stop, program operation auto start)
Additional Functions
Power on and Integration time function (up to 65,535 hours), Calibration offset, Time display, Display of power consumption, CO2 discharge andheater operation, Power failure return mode, User configuration information
Heater Circuit Control
Triac zero-cross control
Sensor
K-thermocouple double sensor (for temperature control and independent overheat prevention device)
Safety Device
Self diagnostic functions (temp. sensor abnormal, Heater disconnection, SSR- short, Main relay abnormal, Automatic overheating prevention), Key lock function, Independent overheat prevention, Electric leakage breaker with over current protection
Earth Leakage Breaker
Leak Current/Short Circuit/Over-current Protection, Rated Current Sensitivity 30mA
Independent Overheat Prevention
Set temperature range: 0~250°C
Internal Dimensions*² W×D×H
600×500×500 mm
External Dimensions*² W×D×H
730×696×910 mm
Internal Capacity
150L
Shelf Plate With Standard Load
~15kg/pcs.
Shelf Rest Step Number / Shelf Rest Pitch
13 steps / 30mm
Power Source 50/60Hz
AC115V 11A
Weight
~77kg
Shelf Plate
Stainless steel, 1pc on the bottom screwed
Shelf Plate / Bracket
2 pcs. / 4 pcs.

Product description

150L programmable forced convection oven with PID control, eco-friendly design, 210°C max temp, 99-step program, power fail recovery.

The Yamato DNE-611 is a high-performance, eco-friendly forced convection oven designed to reduce power consumption by approximately 40% compared to earlier models. It features a 150L chamber capacity and operates at 220V.

Key Technical Features:

  • Temperature control: High precision PID microprocessor control with ±0.5°C accuracy at 210°C
  • Temperature range: Room Temperature +20°C to 210°C
  • Temperature distribution accuracy: ±2.0°C at 210°C
  • Maximum temp rise time: Approx. 70 minutes
  • Circulation: Forced air circulation via Scirocco fan with 10W capacitor motor
  • Materials: Chamber made of stainless steel; exterior of chrome-free electro-galvanized steel with chemical-proof baked finish; insulation via glass wool
  • Capacity and Dimensions: Internal 600×500×500 mm (150L); External 730×696×910 mm
  • Door: Single swing, left side
  • Programming: Up to 99 steps, 99 pattern repeatable program operation
  • Display: Dual LED displays with green 4-digit and orange 5-digit readouts for temperature and information; digital setting via ▲/▼ keys
  • Timer: Duration operation from 1 min to 99 hours 59 mins; 24-hour time operation setting
  • Additional functions: Calibration offset, power failure recovery mode, user info storage, power consumption & CO2 discharge display, power on/integration time up to 65,535 hours
  • Safety: Independent overheat prevention device; electric leakage breaker with 30mA sensitivity; self-diagnostic functions for sensor and heater faults; key lock function; overcurrent circuit breaker
  • Heater: 1.2 kW controlled by triac zero-cross technique
  • Sensor: K-thermocouple double sensor for temperature control and overheat prevention
  • Exhaust: Two 33mm I.D. exhaust ports on top, cable holes for data acquisition
  • Shelving: One stainless steel shelf plate on bottom standard (load approx. 15kg); 13 shelf steps with 30mm pitch; 2 shelf plates and 4 brackets included
  • Weight: Approximately 77 kg

The DNE-611 supports easy system upgrades with optional settings and allows observation window installation as an option to enhance monitoring.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 31 October 2026