Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
137ºC
Agar Warming Range
After sterilization, agar can be maintained from 45ºC to 60ºC (programmable) to prevent coagulation for up to 20 hours.
Maximum Allowable Pressure
38 psi (0.26MPa)
Pressure Operating Range (gauge)
3 to 30 psi (0.021 to 0.206MPa)
All 17 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 17

Brands
Hirayama
New/Used
New
Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
137ºC
Agar Warming Range
After sterilization, agar can be maintained from 45ºC to 60ºC (programmable) to prevent coagulation for up to 20 hours.
Maximum Allowable Pressure
38 psi (0.26MPa)
Pressure Operating Range (gauge)
3 to 30 psi (0.021 to 0.206MPa)
Sterilization Timer
1 to 250 minutes
Overall Dimensions (W x D x H)
26.0" x 25.6" x 46.4" in (66 cm x 65 cm x 118cm)
Chamber Dimensions (Diameter x Height)
110 liters 16.5" x 31.3" (42.0 cm x 79.5 cm)
Safety Devices
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for Agar
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Warming -> Completion
Programs for Liquids
Heating -> Sterilization -> Auto steam exhaust or ambient cooling (programmable) -> Completion
Programs for Solids
Heating -> Sterilization -> Auto exhaust (fast) -> Completion
Power Source
208V / 220V / 240V, 50 / 60 Hz, single phase
Power Consumption
4000 watts (4000VA)
Shipping Weight
308 lb (140 kg)

Product description

Versatile 110L autoclave with cooling fan, ideal for larger load sterilization.

Hirayama HICLAVE HVA-110 Economical Floor-Standing Autoclave with Cooling Fan, 110L, 208/220/240V

Chamber Volume 110L Sterilization Temperature Range 105C to 135C Chamber Dimensions 16.5" x 31.3" (42.0 cm x 79.5 cm)

Features

  • Space-saving design with lid opening upward.
  • Standard built-in cooling fan for faster post- sterilization cooling.
  • Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
  • Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
  • One-touch lever to easily open and close chamber lid.
  • Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
  • Door-closure sensor prevents a cycle from starting unless the door is closed properly.
  • In-process display shows the status and the progress of sterilization cycle.

The HVA-85 and HVA-110 models incorporate a 85-liter and a 110-liter chamber, respectively. They are self-contained, portable floor models mounted on caster wheels. Equipped with a chamber 16.5” in diameter, they can accommodate significantly larger loads than 50-liter models. They are ideal for the sterilization of fermenters, media, wastes, and laboratory glassware.INCLUDED: The Hirayama HICLAVE HVA-110 Economical Floor-Standing Autoclave with Cooling Fan, 110L, 208/220/240V includes:

  • Power Cord
  • Operator's Manual
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026