Hirayama HICLAVE HG-80 Floor-Standing Autoclave with Automatic Lid, 85L, 208/220/240V

€14,609.16excl. VAT

In stock

Can't find what you're looking for?

Overall (W x D x H)
19.7" x 27.2" x 40.6" (45.5 cm x 69.1 cm x 103.0 cm)
Chamber(Diameter x Height)
76 liters 14.3" x 28.7" (36.4 cm x 73.0 cm)
Temperature Range
105°C to 135°C
Sterilization Timer
1 to 300 minutes
Agar Warming Range
After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
All 21 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 21

Brands
Hirayama
New/Used
New
Overall (W x D x H)
19.7" x 27.2" x 40.6" (45.5 cm x 69.1 cm x 103.0 cm)
Chamber(Diameter x Height)
76 liters 14.3" x 28.7" (36.4 cm x 73.0 cm)
Temperature Range
105°C to 135°C
Sterilization Timer
1 to 300 minutes
Agar Warming Range
After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
Delayed Auto-Start
Program autoclave to start 1 to 99 hours later
Cooling Fan
Switch to turn fan on or off
Air Removal Timer
Programmable, 3 to 9 minutes after temperature has reached 97°C
Steam Venting
Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock
Programmable, 60°C to 97°C for greater safety and flexibility
Sterilization Program Cycles
1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle
Additional Cycles for Agar Dissolution
Cycle for dissolving and keeping agar warm (no sterilization)
Agar Dissolution Protocol
Initially at 60°C-100°C for 1-60 min., then at 45°C-60°C for up to 24 hrs.
Safety Features
Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing
Steam Condenser
15-liter water tank
Drain Water Bottle
2 liters
Power Requirements
220V, 50/60 Hz, single phase
Power Consumption
3.8 kW
Shipping Weight
255 lb (116 kg)

Product description

Advanced autoclave with auto lid, safety interlock, 85L capacity, and 12 programmable cycles for efficient sterilization.

Hirayama HICLAVE HG-80 Floor-Standing Autoclave with Automatic Lid, 85L, 208/220/240V

Chamber Volume 76L Sterilization Temperature Range 105ºC to 135ºC Chamber Dimensions 14.3 x 28.7 in(36.4 x 73.0 cm)

Features

  • Automatic Lid Opening and Closing Button replaces a foot pedal.
  • Safety Interlock senses pressure and temperature and prevents lid from opening during a cycle, when the chamber is pressurized, and when the high temperature can cause boil over.
  • Programmable Auto-Start for running a cycle from 1 to 99 hours later and time for air removal before sterilization.
  • Large (15 liters) / Efficient Steam Condenser ensures no steam exhausts into the lab. The HG-113 and HG-133 incorporate a radiator for this.
  • Over-Flow Lamp indicates that the drain bottle is full and ready to be emptied.
  • Built-in Cooling Fan for faster post-sterilization cooling and shorter completion time.
  • Selectable Rate of steam venting after sterilization.
  • Twelve Programs Cycles can be stored.
  • Large Control and Display Panel improves functionality and shows the progress of the sterilization cycle.

The Hirayama HICLAVE HG-80 is an advanced 85L floor-standing autoclave designed for efficient and safe sterilization. It features an automatic lid opening button to replace the conventional foot pedal and an automatic lid closing button for convenience. Its safety interlock prevents the lid from opening during cycles, ensuring safety when the chamber is pressurized or at high temperatures. The programmable auto-start can delay the start of a cycle by 1 to 99 hours. A large and efficient 15-liter steam condenser prevents steam from exhausting into the lab, complemented by a built-in cooling fan for rapid post-sterilization cooling. Users can select the rate of steam venting post-sterilization and program the air removal time before sterilization begins. Up to twelve program cycles can be stored for easy recall.The HG-80 boasts a large control and display panel, enhancing functionality and cycle progress visibility. Specifications include a chamber size of 76 liters (14.3" x 28.7"), a temperature range of 105°C to 135°C, a sterilization timer from 1 to 300 minutes, and an agar warming range maintainable from 45°C to 60°C for up to 24 hours to prevent coagulation. Additional features include a programmable air removal timer, selectable steam venting rates, and customizable temperature settings for lid interlock release for increased safety and flexibility. The unit is equipped with comprehensive safety features, including a circuit breaker with GFCI, low-water power cut-off, over-temp power cut-off, over-pressure power cut-off, safety valve, and a sensor for improper lid closing. The autoclave comes with a 15-liter water tank for the steam condenser and a 2-liter drain water bottle. It operates on 208/220/240V, 50/60 Hz, single-phase power, with a consumption of 3.8 kW, and ships at a weight of 255 lb (116 kg).INCLUDED: The Hirayama HICLAVE HG-80 Floor-Standing Autoclave with Automatic Lid, 85L, 208/220/240V includes:

  • Power Cord
  • Operator's Manual
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026