58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Hirayama HICLAVE HV-50II Floor-Standing Touchscreen Autoclave, 50L, 120V

€11,518.76excl. VAT

In stock

Can't find what you're looking for?

Chamber Capacity
50L
Chamber Dimensions (Dia.x H)
11.8 x 28 in (30 x 71 cm)
Operation Modes
5 modes (LIQUID, SOLID, WASTE, AGAR, DISSOLUTION) Settings can be registered in 8 memories.
Temperature Setting Range Sterilization
105°C to 135°C Variable
Temperature Setting Range Dissolution
60°C to 100°C
All 25 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 25

Brands
Hirayama
New/Used
New
Chamber Capacity
50L
Chamber Dimensions (Dia.x H)
11.8 x 28 in (30 x 71 cm)
Operation Modes
5 modes (LIQUID, SOLID, WASTE, AGAR, DISSOLUTION) Settings can be registered in 8 memories.
Temperature Setting Range Sterilization
105°C to 135°C Variable
Temperature Setting Range Dissolution
60°C to 100°C
Temperature Setting Range Warming
45°C to 60°C
Temperature Setting Range Agar Dissolution
Heating at 60°C to 100°C for up to 1 hour Followed by 45°C to 60°C
Lid Lock
LIQUID, AGAR, DISSOL modes: 60°C to 95°C Variable SOLID, WASTE modes: 60°C to 97°C Variable
Time Setting Range
Sterilization: 1 to 250 minutes, Remaining time is displayed Dissolution: 1 to 60 minutes, Remaining time is displayed Warming: 20 Hours, Fixed Air Removal: 3 to 9 min variable
Auto-Start
Program autoclave to start 1 min to 1 week later
Exhaust Setting
3 levels (Without Exhaust, Fine Exhaust, Small Amount of Exhaust)
Maximum Working Pressure
27 PSI (0.186MPa)
Thermometer
Digital display 5.0°C to 137.9°C
Pressure Gauge
Digital display 0MPa - 0.3MPa / Analog display 0MPa - 0.4MPa
Safety Devices
Pressure safety valve, Over-current and earth leakage breaker, Low water cut off device
Alarms, Error Display
Low water heating, Temperature sensor wire disconnection, Over temperature, Over cool, Over pressure, Lid abnormality, Abnormality in lid opening / closing lever
Pressure Vessel Category
Small sized pressure vessel
Chamber Material
Stainless steel (SUS304)
Power Connection
Ring terminal
Outside Dimensions (W x D x H)
21.6 x 21 x 41 in. (54.7 x 53.2 x 104.6 cm)
Weight (Approx.)
132.3 lbs (60 kg)
Required Power Supply Facility
2.0kW
Electrical Requirements
120V 50/60 Hz, 2000W

Product description

Reliable 50L autoclave with touchscreen, multiple safety features, and programmable settings for efficient sterilization.

Hirayama HICLAVE HV-50II Floor-Standing Touchscreen Autoclave, 50L, 120V

Chamber Volume 50L Sterilization Temperature Range 105°C to 135°C Chamber Dimensions (Dia. x H) 11.8 x 28 in (30 x 71 cm)

Features

  • Space-saving design with upward lid opening
  • Five operation modes with up to 8 memory settings per mode
  • Color touch panel for intuitive operation
  • Electro-mechanical lid lock system with one-touch lever
  • Dual interlock mechanism for enhanced lid safety
  • Programmable auto-start function, up to 1 week in advance
  • Digital and analog displays for temperature and pressure monitoring
  • Air removal system with dual detection for consistent sterilization
  • 11 alarms, including low water heating and over-temperature, with alarm history display
  • Memory backup system retains settings during power failures

The Hirayama HICLAVE HV-50II Floor-Standing Touchscreen Autoclave, 50L, 120V, is a versatile and reliable solution for advanced sterilization needs. It offers five operation modes—LIQUID, SOLID, WASTE, AGAR, and DISSOLUTION—each with customizable memory settings for up to 40 cycles. Its space-saving design features an upward lid opening and an intuitive color touch panel that simplifies operation. The electro-mechanical lid lock with a one-touch lever ensures secure and hassle-free use, while the dual interlock mechanism provides additional safety by locking the lid based on both chamber pressure and temperature. The dual air removal system guarantees consistent sterilization, even for difficult loads, and the optional forced cooling unit accelerates cycle completion for faster turnaround times.

This autoclave is equipped with programmable auto-start functionality, allowing users to set operations up to one week in advance. Its robust stainless steel (SUS304) chamber ensures long-term durability, while a comprehensive array of 11 alarms—including warnings for low water heating, over-temperature, and lid abnormalities—enhances safety and reliability. Digital and analog displays for temperature and pressure provide real-time monitoring, and a memory backup system retains programmed settings during power interruptions. With its combination of precision, safety features, and efficiency, the HICLAVE HV-50II is an excellent choice for laboratories requiring dependable sterilization performance.INCLUDED: The Hirayama HICLAVE HV-50II Floor-Standing Touchscreen Autoclave, 50L, 120V includes:

  • Bottom Plate
  • Drainage Hose
  • Exhaust Hose
  • Exhaust Bottle
  • Drain Bottle
  • 2 x Caster Stopper
  • 2 x Round Wire Mesh Basket
  • Power Cord
  • Operator's Guide
  • Manufacturer's Documentaiton
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026