Hirayama HICLAVE HV-50 Floor-Standing Autoclave, 50L, 120V

€10,194.31excl. VAT

In stock

Can't find what you're looking for?

Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
10°C to 137ºC
Temperautre Warming Range
45ºC to 60ºC
Agar Dissolution
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC (programmable for up to 20 hours to prevent coagulation)
Pressure Operating Range (gauge)
3 to 30 psi (0.02 to 0.206MPa)
All 20 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 20

Brands
Hirayama
New/Used
New
Temperature Operating Range
105ºC to 135ºC
Temperature Display Range
10°C to 137ºC
Temperautre Warming Range
45ºC to 60ºC
Agar Dissolution
Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC (programmable for up to 20 hours to prevent coagulation)
Pressure Operating Range (gauge)
3 to 30 psi (0.02 to 0.206MPa)
Maximum Allowable Pressure
38 psi (0.26MPa)
Sterilization Timer
1 to 250 minutes
Delayed Auto-start Timer
Program autoclave to start 1 minute to 7 days later
Overall Dimensions (W x D x H)
20" x 21" x 41" (51 cm x 53 cm x 104 cm)
Chamber Dimensions (Diameter x Height)
50 liters 11.8" x 28.0" (30 cm x 71 cm)
Safety Devices
Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
Programs for agar
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion
Programs for liquids
Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion
Programs for solids
Heating -> Sterilization -> Exhaust (fast, default) -> Completion
Programs for melting agar or for faster start-up
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion
Power source
120V, 50/60 Hz (220V/240V available)
Power consumption
2000 watts (2000VA)
Shipping Weight
180 lb (82 kg)

Product description

Compact, versatile autoclave ideal for sterilization in limited lab spaces.

Hirayama HICLAVE HV-50 Floor-Standing Autoclave, 50L, 120V

Chamber Volume 50L Sterilization Temperature Range 105°C to 135°C Chamber Dimensions 11.8" x 28.0" (30 cm x 71 cm)

Features

  • Space-saving design with lid opening upward.
  • Programmable auto-start for initiating a cycle up to 1 week later.
  • Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
  • Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
  • One-touch lever to easily open and close chamber lid.
  • Programmable rate of steam exhaust.
  • Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.

The 25-liter (HV-25), 50-liter (HV-50), 85-liter (HV-85), and 110 liter (HV-110) Autoclaves are self-containers, portable floor models mounted on caster wheels. They occupy minimum floor space and can fit conveniently into many locations in the laboratory. Their many uses include the sterilization of agar, media, wastes, glassware, and fermenters, especially for the larger models.INCLUDED: The Hirayama HICLAVE HV-50 Floor-Standing Autoclave, 50L, 120V includes:

  • Power Cord
  • Operator's Manual
  • 1 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026