58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Edwards E1M18 Oil-Sealed Rotary Vane Vacuum Pump for Laboratory and Industrial Use

Price on request

In stock

Can't find what you're looking for?

Product Type
Oil-Sealed Rotary Vane Vacuum Pump
Pump Design
Single-stage, direct-drive sliding vane
Ultimate Pressure
3 Pa
Default Oil Type
Edwards Ultragrade Performance 19
Maximum Oil Capacity
1.4 L
All 17 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 17

Brands
Edwards Vacuum
New/Used
Used
Product Type
Oil-Sealed Rotary Vane Vacuum Pump
Pump Design
Single-stage, direct-drive sliding vane
Ultimate Pressure
3 Pa
Default Oil Type
Edwards Ultragrade Performance 19
Maximum Oil Capacity
1.4 L
Inlet Connection
DN25 ISO-KF (NW25)
Outlet Connection
15 mm hose nozzle, 3/4 in BSPP female
Gas Ballast
Adjustable multi-turn valve
Motor Cooling
Motor-mounted cooling fan
Motor Protection
Automatic thermal-overload protection
Oil Monitoring
Reservoir sight glass
Mounting
Aluminum-alloy baseplate with rubber pads
Dimensions
7 x 21 x 23 in
Weight
84 lb
Electrical Requirements
230V, 60Hz, 5.5 A

Product description

Single-stage oil-sealed rotary vane vacuum pump, 3 Pa ultimate pressure, adjustable gas ballast, DN25 ISO-KF inlet.

The Edwards E1M18 is a single-stage oil-sealed rotary vane vacuum pump designed for laboratory and industrial vacuum applications including biotechnology workflows and molecular diagnostics requiring reliable low-pressure generation. This pump features a direct-drive motor coupled flexibly to the sliding-vane mechanism, ensuring smooth operation and extended service life.

Key specifications include:

  • Ultimate pressure: 3 Pa, suitable for applications demanding high vacuum such as bioprocessing containment and synthetic biology setups
  • Inlet connection: DN25 ISO-KF (NW25), allowing integration with standard vacuum lines and instrumentation common in cell imaging and analytical research
  • Outlet connection: 15 mm hose nozzle with 3/4-inch BSPP female fitting
  • Gas ballast: Manually adjustable multi-turn valve to reduce vapor condensation and oil contamination, essential for processing condensable vapors in molecular cloning and biomanufacturing
  • Oil system: Internally lubricated with Edwards Ultragrade Performance 19 oil (maximum capacity 1.4 L), including oil distribution valve to prevent oil back-suction during shutdown
  • Motor: Totally enclosed with dedicated fan cooling and automatic thermal-overload protection to safeguard against temperature-induced failures
  • Construction: Mounted on an aluminum-alloy baseplate with rubber pads for vibration isolation
  • Monitoring: Reservoir sight glass for oil level and condition checks, with separate fill and gravity-drain ports for maintenance ease
  • Electrical: Operates on 230 V, 60 Hz, with 5.5 A current draw

This vacuum pump is widely used in biomedical engineering, clinical diagnostics, and research laboratories where stable vacuum levels and contamination control are critical. Its design supports applications like live-cell imaging chambers, fluorescence analysis setups, and critical biomanufacturing stages. The adjustable gas ballast valve makes it particularly effective for environments dealing with humid or vapor-laden gases, common in molecular biology and synthetic biology research workflows.

Included with the Edwards E1M18 are the oil mist filter (EMF20), user manual, and a 230 V power cord. This pump is backed by a 30-day warranty and rigorous factory testing, ensuring dependable performance in demanding laboratory environments.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026