Optical system
Color Corrected Infinity Optical System (CCIS®)
Observation tube
Trinocular head, Siedentopf type, 360° swiveling
Inclination
25° inclined, 360° rotating (storage saving), 360° swivelling
Trinocular light split
Fixed 50:50
Interpupillary distance
48-75mm
All 32 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 32

Brands
Motic
New/Used
Used
Optical system
Color Corrected Infinity Optical System (CCIS®)
Observation tube
Trinocular head, Siedentopf type, 360° swiveling
Inclination
25° inclined, 360° rotating (storage saving), 360° swivelling
Trinocular light split
Fixed 50:50
Interpupillary distance
48-75mm
Diopter adjustment
On both eyepieces, +/- 5 diopter
Eyepieces
Widefield UC-WF10X/20mm with diopter adjustment
Nosepiece
Reversed quadruple
Objective classification
CCIS® UC Plan Achromatic (Pb free)
Objectives
4X/0.10 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 100X/1.25/S-Oil (WD 0.16mm)
Objective mounting thread
W 4/5"x1/36" (RMS standard)
Stand type
Upright
Stage
Mechanical stage with built-in low position rackless coaxial stage control and sample holder
Stage size
140x135mm
Travel range X&Y
75x40mm
Condenser
Focusable and centerable Abbe condenser N.A. 0.90/1.25 with slot for contrast sliders
Diaphragm
Iris diaphragm
Focus mechanism
Coaxial coarse and fine focusing system with tension adjustment
Fine focus precision
2μm
Focusing stroke
25mm
Upper limit stop
Upper limit stop preset but adjustable
Filter holder
On top of the illuminator
Transmitted illumination
Fixed Koehler LED 1W with intensity control
Illumination features
Nosepiece LED light intensity indicator
Transformer
Internal
Power supply
110-240V (CE), USB 2.0 for battery pack
Other features
USB 2.0 for external camera power
Accessories included
Dust cover, power cord, Allen key
Dimensions LxWxH
282x210x396mm
Net weight
7.5kg

Product description

Trinocular microscope with CCIS optics, LED Koehler illumination, mechanical stage, and 10MP USB digital camera.

Microscope:

  • Optical system: Color Corrected Infinity Optical System (CCIS®)
  • Observation tube: Trinocular head, Siedentopf type, 360° swiveling with fixed 50:50 light split
  • Inclination: 25° inclined; rotates 360° for storage
  • Interpupillary distance: 48–75 mm, diopter adjustment ±5 on both eyepieces
  • Eyepieces: Widefield UC-WF10X/20mm with diopter adjustment
  • Nosepiece: Reversed quadruple, RMS standard (W 4/5"x1/36")
  • Objectives: CCIS® UC Plan Achromatic (Pb free) - 4X/0.10 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 100X/1.25/S-Oil (WD 0.16mm)

Mechanical stage:

  • Size: 140 x 135 mm
  • Travel range X & Y: 75 x 40 mm
  • Control: Rackless coaxial with built-in low position and sample holder

Condenser & illumination:

  • Condenser: Abbe, focusable and centerable, N.A. 0.90/1.25, slot for contrast sliders
  • Diaphragm: Iris diaphragm
  • Illumination: Fixed Koehler LED 1W with intensity control, nosepiece LED light intensity indicator

Focus system:

  • Coaxial coarse and fine focus with tension adjustment
  • Fine focus precision: 2 μm
  • Focusing stroke: 25 mm
  • Upper limit stop: Preset and adjustable

Power & dimensions:

  • Power supply: 110-240 V (CE certified), includes USB 2.0 for battery pack and external camera power
  • Dimensions (LxWxH): 282 x 210 x 396 mm
  • Net weight: 7.5 kg

Accessories included:

  • Moticam BTI10 digital camera (USB 2.0)
  • Compatible C-mount adapter
  • Dust cover, power cord, Allen key

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026