58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V

NewMemmertFurnacesUnited States

€12,439.2excl. VAT

In stock

Can't find what you're looking for?

Volume
161L (5.68 Cu. Ft.)
Working Temperature Range
At least 10°C above ambient to +250°C
Setting Temperature Range
+20 to +250°C
Setting Resolution (Temperature)
Up to 99.9°C: 0.1°C / From 100°C: 0.5°C
Display Resolution (Actual Values)
0.1°C
All 31 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 31

Brands
Memmert
New/Used
New
Volume
161L (5.68 Cu. Ft.)
Working Temperature Range
At least 10°C above ambient to +250°C
Setting Temperature Range
+20 to +250°C
Setting Resolution (Temperature)
Up to 99.9°C: 0.1°C / From 100°C: 0.5°C
Display Resolution (Actual Values)
0.1°C
Temperature Sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring
Control Panel
ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays
Timer
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function HeatBALANCE
Adjusts heating performance distribution between the upper and lower heating circuits from -50% to +50%
Function SetpointWAIT
Process time does not start until the set temperature is reached
Calibration
Three freely selectable temperature values
Fan
Forced air circulation by quiet air turbine, adjustable in 10% steps for each segment individually
Fresh Air
Pre-heated fresh air admixture via electronically adjustable air flap
Vent
Vent connection with restrictor flap
Programming
AtmoCONTROL software on a USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Temperature Control
Independently working, digitally adjustable electronic microprocessor overtemperature monitor TWW, protection class 3.1
Temperature Control (TB)
Mechanical temperature limiter TB, protection class 1 according to DIN 12880, switches off heating 20°C above nominal temperature
AutoSAFETY
Integrated over- and undertemperature protection "ASF", heating switched off in case of overtemperature
Autodiagnostic System
For fault analysis
Alarm
Visual and acoustic
Door
Fully insulated stainless steel doors on two sides
Interior
Easy-to-clean stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides
Max. Number of Shelves
8
Max. Loading Per Shelf
44 lbs
Max. Loading of Chamber
462 lbs
Internal Dimensions (W x H x D)
22" x 28.3" x 15.7" (56 x 72 x 40 cm)
External Dimensions (W x H x D)
29.3" x 48.5" x 22.9" (74.4 x 123.19 x 58.2 cm)
Net Weight
Approx. 265 lbs
Electrical Load
115 V, 50/60 Hz, approx. 1800 W

Product description

Precision and reliable performance with robust safety features, ideal for demanding laboratory tasks.

Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V

Working Temperature Range At least 10°C above ambient to +250°C Setting Resolution (Temperature) Up to 99.9°C: 0.1°C / From 100°C: 0.5°C Chamber Volume 161L (5.68 Cu. Ft.)

Features

  • Working temperature range from at least 10°C above ambient to +250°C
  • Volume capacity of 161L (5.68 Cu. Ft.) with stainless steel interior
  • TwinDISPLAY with adaptive multifunctional digital PID-microprocessor controller and dual high-definition TFT-color displays
  • Forced air circulation adjustable in 10% steps, with pre-heated fresh air admixture
  • AutoSAFETY system with integrated over- and undertemperature protection
  • Supports up to 8 shelves with a maximum chamber load of 462 lbs
  • Three freely selectable temperature calibration points
  • Function SetpointWAIT ensures process begins only once set temperature is reached

The Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V offers advanced precision and reliability with a working temperature range from at least 10°C above ambient to +250°C. Designed with a spacious 161L (5.68 cu.ft.) interior, this oven features a stainless steel chamber reinforced with deep-drawn ribbing, providing both durability and ease of cleaning. The TwinDISPLAY control system, equipped with two high-definition TFT-color displays, allows for adaptive multifunctional temperature management, ensuring accurate control via two Pt100 sensors in a 4-wire circuit for mutual monitoring. Additional features include forced air circulation, adjustable fan speed in 10% increments, and pre-heated fresh air admixture for optimal thermal distribution.

For enhanced safety, the Memmert UF160TS includes the AutoSAFETY system, which provides integrated over- and undertemperature protection, as well as a mechanical temperature limiter (TB) that switches off heating at 20°C above the nominal temperature. The Function SetpointWAIT ensures the process begins only once the set temperature is reached, while the Function HeatBALANCE allows precise adjustment of heating performance. With a maximum loading capacity of 462 lbs, spread across up to 8 shelves, this oven is ideal for demanding laboratory applications requiring consistent, reliable performance.

INCLUDED: The Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V includes:

  • 2 Stainless Steel Grid
  • Tilt Protection Wall Bracket
  • Base Cladding with Screw Connection
  • Calibration Certificate
  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 3 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026