Volume
1060 L (37.4 cu. ft.)
Setting Temperature Range (without light, with humidity)
+5 to +70°C
Setting Temperature Range (without light, without humidity)
0 to +70°C
Setting Accuracy Temperature
0.1°C
Temperature Sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
All 34 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 34

Brands
Memmert
New/Used
New
Volume
1060 L (37.4 cu. ft.)
Setting Temperature Range (without light, with humidity)
+5 to +70°C
Setting Temperature Range (without light, without humidity)
0 to +70°C
Setting Accuracy Temperature
0.1°C
Temperature Sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Setting Range Humidity
10 - 90 % rh
Humidity Supply
Humidity supply with distilled water from external tank by self-priming pump
Humidification
Humidification by hot steam generator
Dehumidification
Dehumidification by cold trap using the Peltier technology
Setting Accuracy Humidity
0.5 % rh
ControlCOCKPIT
TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
Language Setting
German, English, Spanish, French, Polish, Czech, Hungarian
Adjustable Parameters
Temperature (Celsius or Fahrenheit), relative humidity, program time, time zones, summertime/wintertime
Timer
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT
The process time does not start until the set temperature is reached
Calibration
Three freely selectable values each, temperature and humidity
Interface
Ethernet LAN, USB
Programming
AtmoCONTROL software on a USB stick for programming, managing and transferring programs via Ethernet interface or USB port
Temperature Control
Over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETY
Additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
Autodiagnostic System
Integral fault diagnostics for temperature and humidity control
Alarm
Visual and acoustic
Standard Works Calibration Certificate
+25 °C / 40 % rh and +40 °C / 75 % rh
Door
Fully insulated stainless steel door with 2-point locking (compression door lock)
Inner Glass Door
Equipped
Max. Number of Shelves
14
Max. Loading of Chamber
440 lbs (200 kg)
Max. Loading per Shelf
44 lbs (20 kg)
Net Weight
574 lbs (260.1 kg)
Internal Dimensions (W x H x D)
40.9 x 47.2 x 23.6 in. (104 x 120 x 85 cm)
External Dimensions (W x H x D)
48.2 x 67.7 x 39.6 in. (122.4 x 172 x 100.5 cm)
Electrical Load
115 V, 50/60 Hz, approx. 1400 W

Product description

Efficient 1060L chamber for stability testing with precise climate control.

Memmert HPP1060eco Climate Chamber 1060L, 115V Setting Temperature Range (without light, with humidity) +5 to +70°C Setting Range Humidity 10 to 90 % rh Chamber Volume 1060 L (37.4 cu. ft.) Features

  • Generous volume capacity of 1060 L (37.4 cu. ft.) for versatile climate and stability testing
  • Temperature range settings from +5 to +70°C with humidity, and 0 to +70°C without humidity
  • Precise temperature control with 0.1°C setting accuracy and dual Pt100 sensors for reliable performance
  • Humidity range adjustable from 10% to 90% RH with efficient hot steam generator and Peltier dehumidification
  • Intuitive TwinDISPLAY ControlCOCKPIT featuring two high-definition TFT-color displays
  • Multi-language settings with support for German, English, Spanish, French, Polish, Czech, and Hungarian
  • Durable stainless steel door with 2-point locking and interior glass door for added insulation
  • Convenient data programming and management with AtmoCONTROL software via USB or Ethernet

The Memmert HPP1060eco Climate Chamber 1060L, 115V is expertly designed to provide consistent and precise environmental conditions for sensitive testing applications. With a spacious 1060 L (37.4 cu. ft.) interior, it offers ample space for extensive climate and stability testing needs. Its temperature range spans from +5 to +70°C with humidity and 0 to +70°C without humidity, providing versatility for a wide array of research and material testing scenarios. The highly accurate 0.1°C temperature setting resolution, powered by dual Pt100 sensors, ensures reliable readings and consistent conditions essential for exacting scientific requirements.

The HPP1060eco integrates cutting-edge control technology with its TwinDISPLAY ControlCOCKPIT, featuring dual high-definition TFT-color displays for real-time monitoring and adjustments. Designed with an energy-efficient Peltier heating and cooling system, it utilizes advanced humidification by hot steam generator and Peltier-driven dehumidification, delivering dependable humidity control within a range of 10 to 90% RH. Programmed and managed through AtmoCONTROL software, accessible via USB or Ethernet, this climate chamber also includes AutoSAFETY temperature protection, visual and acoustic alarms, and built-in self-diagnostics. Ideal for ICH-compliant stability testing and environmental simulations, this durable, stainless-steel chamber ensures reliability, precision, and performance in any lab setting.

INCLUDED: TheMemmert HPP1060eco Climate Chamber 1060L, 115V includes:

  • 2 Stainless Steel Grid
  • Tilt Protection Wall Bracket
  • USB Drive w/ Software & AtmoCONTROL Manual
  • Calibration Certificate
  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 3 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 3 November 2026