Temperature Control
±0.1°C
Temperature Range
5°C above ambient to 55°C (131°F)
Temperature Uniformity
±0.2°C @ 37°C (98.6°F)
Tracking Alarm
User-programmable high/low
Sensor
Precision thermistor
All 28 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 28

Brands
VWR
New/Used
Used
Temperature Control
±0.1°C
Temperature Range
5°C above ambient to 55°C (131°F)
Temperature Uniformity
±0.2°C @ 37°C (98.6°F)
Tracking Alarm
User-programmable high/low
Sensor
Precision thermistor
Controller
Independent analog electronic
Setability
0.1%
CO2 Control
Better than ±0.1%
CO2 Range
0-20%
Inlet Pressure Required
15 PSIG (1.0 bar)
CO2 Sensor
TC
Readability & Setability
0.1%
rH
Ambient to 95% @ 37°C (98.6°F)
Humidity Pan
0.8 gal. (3 L), standard
Fill Port
3/8” hose (barbed)
Drain Port
1 1/4” hose (barbed)
Access Port with Filter
1.3” (3.3 cm) with removable silicone plug
CO2 Inlet
1/4” hose (barbed)
Water Jacket Volume
11.7 gal. (43.5 L)
Interior Volume
6.5 cu. ft. (184.1 L)
Dimensions Interior (W x H x D)
18X17X24”
Interior
Type 304, mirror finish, stainless steel
Exterior
18 gauge, cold-rolled steel, powder-coated
Dimensions Exterior (W x H x D)
27x25x79″
Power
115v, 50/60hz, 3.6a
Weight
550 lbs (when stacked)

Product description

Water jacketed CO2 incubator with ±0.1°C temperature control and HEPA filtration, ideal for stable cell culture growth.

The VWR Symphony Double Stacked Water Jacketed CO2 Incubator is engineered for precise environmental control essential in cell culture, tissue engineering, and biotechnology workflows. Its triple-wall construction with an 11.7-gallon temperature-treated water jacket ensures superior temperature retention and uniformity (±0.2°C at 37°C), which is critical for sensitive molecular diagnostics and bioprocessing applications.

Key technical features include:

  • Temperature control range of 5°C above ambient to 55°C, with ±0.1°C accuracy using a precision thermistor sensor
  • CO2 control accuracy better than ±0.1%, adjustable from 0–20%, supporting optimal conditions for cell metabolism and synthetic biology research
  • Polished Type 304 mirror-finish stainless steel interior (6.5 cu. ft. volume) designed for contamination resistance and easy sanitation
  • Fan-assisted airflow combined with a HEPA filtration system protecting cultures from airborne contaminants and ensuring rapid temperature recovery after door opening
  • Intuitive analog control interface displaying heat and CO2 status with user-programmable alarms for temperature, CO2, humidity, low water, and door ajar conditions
  • Removable stainless-steel shelves and a 3-L humidity pan simplify cleaning and maintenance, supporting sterile environments required in biomanufacturing pipelines
  • Access and inlet ports designed for ease of integration with gas and instrumentation setups

Built on reliable analog electronic control technology with a user-friendly interface, this incubator is widely adopted in biomedical engineering, clinical diagnostics, and live-cell imaging areas requiring stable incubation conditions. The model's robustness against power fluctuations makes it particularly suited for labs facing environmental variations.

Overall, the VWR Symphony CO2 Incubator is an essential instrument for labs focusing on molecular cloning workflows, cell line development, and synthetic biology research, where precise environmental control directly impacts experimental reproducibility and productivity.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026