Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

AIRTECH SMARTFLOW BSC-1304 II A2-cover
AIRTECH SMARTFLOW BSC-1304 II A2

Thanks to their highly efficient ULPA filters, AIRTECH SMARTFLOWAirtech BSC-1304 II A2 Class II-A2 b (more)iological safety cabinets are designed to protect both samples, the operator and the laboratory environment when working with potentially infectious agents. Its high qualities backed by a series of air quality certifications, filters, structure, electrical components and diversity of sizes provide the operator with the greatest comfort and safety when working. It can be used in hospitals, research centers and life science companies in general. AIRTECH SMARTFLOW Class II-A2 biosafety cabinet. Working size 130x79x200 cm (LxFxW). Centrifugal turbine with adjustable speed. Flow rate upward 0.53 ± 0.025 m / s, downward 0.33 ± 0.025 m / s. 30/70 air recirculation (exhaust / recirculation). ULPA extraction and discharge filters (according to IEST-RP-CC001.3), with an efficiency of 99.999% for a particle size between 0.1 and 0.3 microns. Front window with double laminated glass. Stainless steel interior. Programmable germicidal UV and LED white light. Two interior plugs. LCD display with indicators of air flow, temperature and humidity of the work area, filter pressure, hours of UV light, hours of filter use. Eco operating mode. Incorrect air flow, filter replacement and front window height alarms. Support structure included. CE certified. Manufactured according to EN 12469; ISO 14644.1 (air quality); ISO29463 (filtration) and EN-61010-1 (electrical safety).

€6,975.00 ex VAT
Spain
clinical laboratory equipment other, biological safety cabinets
Airtech BSC-1304 II A2-cover
Airtech BSC-1304 II A2

AIRTECH SMARTFLOW Class II-A2 biosafety cabinet. Working size 130x79x200 cm (LxFxW). Centrifugal tur (more)bine with adjustable speed. Flow rate upward 0.53 ± 0.025 m / s, downward 0.33 ± 0.025 m / s. 30/70 air recirculation (exhaust / recirculation). ULPA extraction and discharge filters (according to IEST-RP-CC001.3), with an efficiency of 99.999% for a particle size between 0.1 and 0.3 microns. Front window with double laminated glass. Stainless steel interior. Programmable germicidal UV and LED white light. Two interior plugs. LCD display with indicators of air flow, temperature and humidity of the work area, filter pressure, hours of UV light, hours of filter use. Eco operating mode. Incorrect air flow, filter replacement and front window height alarms. Support structure included. CE certified. Manufactured according to EN 12469; ISO 14644.1 (air quality); ISO29463 (filtration) and EN-61010-1 (electrical safety). Thanks to their highly efficient ULPA filters, AIRTECH SMARTFLOWAirtech BSC-1304 II A2 Class II-A2 biological safety cabinets are designed to protect both samples, the operator and the laboratory environment when working with potentially infectious agents. Its high qualities backed by a series of air quality certifications, filters, structure, electrical components and diversity of sizes provide the operator with the greatest comfort and safety when working. It can be used in hospitals, research centers and life science companies in general.

€4,375.00 ex VAT
Spain
cryogenics, laboratory modules
Agilent 1260 Fluorescence Detector-cover
Agilent 1260 Fluorescence Detector

Agilent Infinity 1260 Fluorescence Detector (FLD) G1321B Spectra. Firmware A.07.02 8 ul Flow Cell. K (more)eeps original packaging. The FLD provides quantitative data and fluorescence spectra from a single run. Simultaneous detection of multiple wavelengths improves sensitivity and selectivity. Features include: Rotating gratings for on-line, multi-signal spectral data acquisition without loss of sensitivity. Lower limits of detection with Raman S/N > 3000 (using dark signal noise reference). Spectra and quantitative data from a single run. Simplified optical design to optimize baseline stability. Resolution gain of up to 100% in fast LC using 145 Hz data acquisition rate. Long life xenon lamp for maximum sensitivity. Long life flash lamp (> 4000 hours). Easy front access allows quick inspection or change of the flow cell. Agilent Infinity 1260 Fluorescence Detector (FLD) G1321B Spectra. Lower detection limits and easier spectral analysis for HPLC and UHPLC. As a stand-alone detector or configured in an automated system, the Agilent 1260 Infinity Spectra Fluorescence Detector brings highly sensitive fluorescence detection to your lab. This easy-to-use detector provides quantitative data and fluorescence spectra from a single signal. Simultaneous multiple wavelength detection improves sensitivity and selectivity. Use online spectral information for rapid method optimization and separation quality verification. High-speed fluorescence detection data processing up to 145Hz, keeping pace with ultra-fast LC analysis speed.

€8,750.00 ex VAT
Spain
optical detectors
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]