Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

All categories

Zeiss Axio Vert.A1 FL Inverted Transmitted Light Microscope Lab-cover
Zeiss Axio Vert.A1 FL Inverted Transmitted Light Microscope Lab

Zeiss Axio Vert.A1 FL Inverted Microscope This system was removed from a university lab where it was (more) surplus to requirements. The microscope is in very clean cosmetic condition. Four 27mm to RMS adapters have been fitted, allowing the use of standard RMS objectives. The microscope has been tested with an objective from stock and works as expected, though no objectives are currently fitted. The instrument is configured as follows: - 1 x Microscope stand Axio Vert.A1 FL (431030-9010-000) - Nosepiece 2xH / 3xHDIC M27 and carrier for transmitted-light illumination - Reflector modules: DAPI, FITC, TRITC, empty - 1 x LD condenser 0.55 for H Ph PlasDIC DIC (424228-9030-000) - Position 1: empty - Position 2: 424228-9060 0.05T Neutral density filter 0.05 - Position 3: 426717-9170 Ph1/0.55 Phase stop Ph1/0.55 - Position 4: 426717-9180 Ph2/0.55 Phase stop Ph2/0.55 - Position 5: empty - 1 x Illuminator LED for Axio Vert transmitted light (423004-9020-000) - 1 x Stop slider A 14x40mm with aperture/luminous field diaphragm (423730-9151-000) - 1 x Binocular tube 45º/23 (425523-9000-000) with 2 x 444036-9000 eyepieces PI 10x/23 - 1 x Mirror 100%, 26x36mm (452531-0001-010) with intermediate phototube H=50mm, left port (425146-9030-000) - 1 x Camera adapter 60N-C 2/3" 0.5x (426112) - 1 x Ergo Intermediate piece H=50mm for optimization of viewing height (425146-9040-00) - 1 x Specimen stage 232x230mm with hardcoat anodized surface (432037-9000-000) - Object guide M, 130x85mm, for Axio Vert (432333-9040-000) - 1 x QImaging QIClick Camera (01-QIClick-R-F-CLR-12), Colour 12 Bit, Firewire operation

£5,000.00 ex VAT
United Kingdom
microscopes
Edinburgh Instruments Time Correlated Single Photon Counting System-cover
Edinburgh Instruments Time Correlated Single Photon Counting System

Edinburgh Instruments Time-Correlated Single Photon Counting System This system was removed from a u (more)niversity lab where it was surplus to requirements. Although all units successfully powered on, we cannot test it completely at our facility. Condition varies as stated below each item. The system includes the following components: Edinburgh Instruments Spectrometer SystemSerial#: 178 The item is in good cosmetic condition with all components present. It powers on and successfully pairs with the control box, PMT Cooler Controller & PC with Software. The following tests were conducted: 1. Excitation Mono Successfully Initialised2. Emission1 Mono Successfully Initialised3. Excitation Polariser Successfully Initialised4. Emission1 Polariser Successfully Initialised5. Sample Holder Temperature Successfully Read6. nF Iris did not initialise (nF Iris Cable present but unable to find port)7. TAC Range & Scaler Successfully Initialised All tests were performed using CD900 Test software. However, unable to open EAI Level 2 Edinburgh Instruments CD900 Software due to requiring Software Protection Device. Additionally, the system includes: Edinburgh Instruments Nanosecond Flashlamp HeadModel: nF900Serial#: 095Mfd: 03/2000 The item is in good cosmetic condition and pairs successfully with the Spectrometer System. Edinburgh Instruments nF900 ControllerModel: nF900Serial#: 092Mfd: 03/2000 The item is in good cosmetic condition with all components present. It powers on and successfully pairs with the Spectrometer System, PMT Cooler Controller & PC with Software. All cables shown at the rear are included. Edinburgh Instruments CD900 ControllerModel: CD900Serial#: 112Mfd: 03/2000 The item is in good cosmetic condition with all components present. It powers on and successfully pairs with the Spectrometer System, PMT Cooler Controller & PC with Software. All cables shown at the rear are included. Lastly, the system includes an Elonex ProSentia PC, iiyama ProLite B2290HS Monitor, Elonex Keyboard & Microsoft. All items are in good cosmetic condition and in full working order. The PC runs Windows 98 and the software installed includes EAI Level 2 (requires Software Protection Device), F900 test, and Cd900t (requires Software Protection Device).

£5,000.00 ex VAT
United Kingdom
software development
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]