58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Alloy Products Stainless Steel Jacketed Reactor with Motorized Agitator on Mobile Cart

Price on request

In stock

Can't find what you're looking for?

Description
Model: N/A. Serial Number: 111141-001. Manufactured: 2002. Voltage: N/A. Frequency: N/A. Power Consumption: N/A. Fuse Rating: N/A. Software Version: N/A. Configuration: Jacketed stainless steel reactor vessel with motorized agitator and pressure gauge. Maximum design temperature 230°F, maximum design pressure 10 PSI. Accessories include agitator motor and pressure gauge.
Technical Data
Model: N/A Serial Number: 111141-001 Voltage: N/A Frequency: N/A Power Consumption: N/A Fuse Rating: N/A Software Version: N/A Configuration: Jacketed stainless steel reactor vessel with motorized agitator and pressure gauge Manufacturing Year: 2002
Voltage
N/A
Frequency
N/A
Power Consumption
N/A
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Alloy Products
New/Used
Used
Description
Model: N/A. Serial Number: 111141-001. Manufactured: 2002. Voltage: N/A. Frequency: N/A. Power Consumption: N/A. Fuse Rating: N/A. Software Version: N/A. Configuration: Jacketed stainless steel reactor vessel with motorized agitator and pressure gauge. Maximum design temperature 230°F, maximum design pressure 10 PSI. Accessories include agitator motor and pressure gauge.
Technical Data
Model: N/A Serial Number: 111141-001 Voltage: N/A Frequency: N/A Power Consumption: N/A Fuse Rating: N/A Software Version: N/A Configuration: Jacketed stainless steel reactor vessel with motorized agitator and pressure gauge Manufacturing Year: 2002
Voltage
N/A
Frequency
N/A
Power Consumption
N/A
Fuse Rating
N/A
Software Version
N/A
Configuration
Jacketed stainless steel reactor vessel with motorized agitator and pressure gauge
Manufacturing Year
2002
Accessories
Motorized agitator, Pressure gauge
Dimensions
N/A
Weight
N/A

Product description

The Alloy Products Stainless Steel Jacketed Reactor (Serial No. 111141-001, Manufactured 2002) is engineered for controlled chemical processing and bioprocess applications. This reactor features a robust jacketed stainless steel vessel designed to maintain precise temperature regulation up to 230°F via heated or cooled jacket fluid circulation. It operates safely at a maximum design pressure of 10 PSI, suitable for controlled reaction environments.

Key technical attributes include:

  • Motorized agitator for uniform mixing and enhanced reaction kinetics, essential in molecular diagnostics and synthetic biology workflows.
  • Integrated pressure gauge for real-time monitoring of internal vessel pressure, critical for safe biomanufacturing and pharmaceutical reaction processes.
  • Mounted on a mobile cart to facilitate flexible placement within laboratory and industrial bioprocessing environments.

This jacketed reactor is widely used in biotechnology research, chemical synthesis, and molecular biology applications where precise thermal and pressure control are required. It supports bioprocessing activities such as gene editing experiments and small-scale biopharmaceutical production by providing stable reaction conditions.

Ideal for laboratories focused on biomedical engineering, synthetic biology, and molecular cloning workflows, this reactor vessel enables controlled chemical reactions with efficient heat transfer and agitation, enhancing reproducibility and reaction efficiency in bioprocess engineering.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026