Flow rate range
gradient mode:4 – 400 ml/min in steps of 0.1 mlisocratic mode (P-907 only):4 – 800 ml/min
UV Cell
190-700nm 3 Wavelengths at once
Pressure range
0 – 2 MPa (20 bar, 290 psi)
Pressure meter
Range:0 – 2.5 MPaOver range:+ 10%Offset error: < ± 0.05 MPaScale error:< ±2%
Flow rate accuracy
± 2% (4-400 ml/min, 0-20 bar)
All 13 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 13

Brands
Cytiva
New/Used
Used
Flow rate range
gradient mode:4 – 400 ml/min in steps of 0.1 mlisocratic mode (P-907 only):4 – 800 ml/min
UV Cell
190-700nm 3 Wavelengths at once
Pressure range
0 – 2 MPa (20 bar, 290 psi)
Pressure meter
Range:0 – 2.5 MPaOver range:+ 10%Offset error: < ± 0.05 MPaScale error:< ±2%
Flow rate accuracy
± 2% (4-400 ml/min, 0-20 bar)
Flow rate reproducibility
RSD < 0.5 %
Viscosity
Max. 5 cP
Environment
4- 40° C, 20-95% relative humidity, 84-106 kPa.Degree of protection – IP20
Dimensions
35x25x38
Weight
180lbs
Power
100-240v, 50-60hz, 800va

Product description

The GE AKTA Pilot FPLC System is an automated chromatography platform engineered for precise pilot-scale purification applications, extensively used in molecular biology, biotechnology, and bioprocess development. Featuring *stable gradient control* and *accurate flow monitoring* across a flow rate range of 4–400 mL/min in gradient mode and up to 800 mL/min isocratically (P-907 variant), it ensures reproducible chromatography runs critical to bioprocessing and molecular diagnostics.

Key technical specifications include:

  • UV detection cell operating at wavelengths from 190-700 nm, capable of simultaneous monitoring at 3 wavelengths, enabling detailed protein and biomolecule analysis.
  • Pressure range up to 2 MPa (20 bar, 290 psi), with pressure meter precision and ±2% flow rate accuracy maintaining consistent experimental conditions.
  • Flow rate reproducibility with RSD < 0.5%, supporting highly reliable protein purification, buffer exchange, desalting, and polishing protocols essential in synthetic biology and biomanufacturing research.
  • Modular and hygienic design with external wetted parts for rapid cleaning and configuration changes, minimizing downtime between runs and preserving sample integrity.

Designed for integration in pilot-scale workflows, this FPLC system includes built-in fraction collection and advanced Unicorn software for programmable runs, optimized for *high-resolution purification* in biopharmaceutical production pipelines, gene editing, and live-cell imaging sample preparation. The compact footprint (35x25x38 cm) and professional packaging ensure seamless installation and operation readiness.

The AKTA Pilot is widely adopted in biotechnology research fields requiring scalable, high-precision liquid chromatography, making it integral to workflows ranging from protein engineering to molecular cloning and molecular diagnostics. Its validated accuracy and robust construction make it suitable for clinical diagnostics labs and bioprocessing environments demanding dependable purification technology.

This system is ideal for molecular biology researchers and bioprocess engineers requiring scalable purification solutions with critical flow and detection accuracy, supporting both research and pilot-production biotechnology applications.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 22 October 2026