Circulation Method
Forced convection
Temp. Setting Range
Room temp. +10~210°C
Temp. Control Accuracy
±1°C (at 210°C)
Temp. Fluctuation
±1°C (at 210°C)
Temp. Distribution Accuracy
±3.5°C (at 210°C)
All 30 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 30

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced convection
Temp. Setting Range
Room temp. +10~210°C
Temp. Control Accuracy
±1°C (at 210°C)
Temp. Fluctuation
±1°C (at 210°C)
Temp. Distribution Accuracy
±3.5°C (at 210°C)
Temp. Rising Time
~60min.
Interior / Exterior Material
Stainless Steel / Chrome free electrogalvanized carbon steel sheet coated with chemical-proof baked-on finish
Insulation Material
Glass wool
Heater
SUS 2.4kW
Sensor
K type Thermocouple
Fan Type / Fan Motor
Sirocco Fan / Condenser type motor 30W
Cable Port
I.D. 33mm (right side)
Exhaust Port
I.D. 33mm x 2 (back)
Temperature Control
PID control by microprocessor
Temperature Display
Temp. display: Green 4-digit LED Digital Display (increment: 1°C), Setting temp. display: Orange 5-digit LED Digital Display (increment: 1°C)
Timer
0 min~99 hrs 59 min (increment: 1 min. or 1 hr.)
Heater Control
Triac with Zero-cross control
Operation Function
Fixed temperature, Auto start, Auto stop, Quick auto stop, Program (99 steps, 99 patterns, repeat operation function)
Additional Function
Power on and operation time accumulation function (up to 65535 hours), Calendar time (24 hours), Calibration offset, Accumulated power consumption monitoring, Total CO₂ emission and heater output, Power recovery mode, Save and access operator setting information, key lock
Safety Device
Self-diagnostic functions (Sensor failure, SSR short circuit, Heater failure, Main relay contact failure, Automatic overheat prevention), earth leakage breaker, Independent overheat prevention device
Internal Dimensions WxDxH
600 x 500 x 1000 mm
External Dimensions WxDxH
710 x 650 x 1640 mm
Internal Capacity
300L
Shelf Plate With Standard Load
~15kg/pc
Shelf Rest Step Number / Pitch
29 steps / 30mm
Power Source
115V 21.5A (no plug, round terminal) 220V 11.5A (no plug, round terminal)
Weight
~108kg
Shelf Plate / Bracket
Stainless steel punched metal 4 pcs. / 8 pcs.

Product description

Programmable forced convection dry sterilizer with 300L capacity and precise PID temperature control up to 210°C.

Yamato SK-811 Forced Convection Dry Sterilizer with a 300L internal capacity offers controlled dry heat sterilization with the following features:

  • Circulation Method: Forced convection using Sirocco fan driven by 30W condenser motor
  • Temperature Range: Room temperature +10°C to 210°C
  • Control & Accuracy: PID control by microprocessor with ±1°C accuracy and ±3.5°C distribution at 210°C
  • Heating Element: SUS 2.4 kW heater with Triac zero-cross control
  • Temperature Sensors: K type thermocouple
  • Display: Green 4-digit LED for actual temperature, orange 5-digit LED for set temperature
  • Timer: 0 minutes to 99 hours 59 minutes, adjustable in 1-minute or 1-hour increments
  • Programmability: Up to 99 steps and 99 patterns with repeat operation, auto start/stop, power recovery, and calibration offset
  • Safety Features: Independent overheat prevention device, self-diagnostics (sensor failure, SSR short circuit, heater failure, relay contact failure), and earth leakage breaker
  • Materials: Stainless steel interior; chrome-free electrogalvanized, chemically coated carbon steel exterior
  • Dimensions: Internal WxDxH 600 x 500 x 1000 mm; External WxDxH 710 x 650 x 1640 mm
  • Load Capacity: Shelf load ~15 kg per plate, 4 stainless steel shelves included with 8 brackets; 29 shelf positions at 30 mm pitch
  • Additional Functions: Power and operation time accumulation (up to 65,535 hours), calendar time clock, monitoring of accumulated power consumption, total CO₂ emission, heater output, key lock for operator settings
  • Connectivity: Cable port with 33 mm diameter on right side; two exhaust ports at back, 33 mm diameter each
  • Power Supply: Available in 115V 21.5A or 220V 11.5A configurations (no plug, round terminal)
  • Weight: Approximately 108 kg

This sterilizer is designed for laboratory and industrial applications requiring precise dry heat sterilization with programmable operation and enhanced safety controls.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026