58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Yamato FO-210CR 3.75L Muffle Furnace with Communication Port (220V)

From€3,225.08excl. VAT

In stock

Can't find what you're looking for?

Operating Temp. Range
100~1150°C
Temp. Control Accuracy
±2°C (at 1150 ° C)
Max. Temp. Reaching Time
~60min.
Exterior Material
Cold rolled steel plate with baked-on melamine resin finish
Internal Material
Ceramic fiber
All 23 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 23

Brands
Yamato Scientific
New/Used
Used
Operating Temp. Range
100~1150°C
Temp. Control Accuracy
±2°C (at 1150 ° C)
Max. Temp. Reaching Time
~60min.
Exterior Material
Cold rolled steel plate with baked-on melamine resin finish
Internal Material
Ceramic fiber
Sensor
R-thermocouple
Heater
Iron-chrome wire 1.5kW
Exhaust Port
ø20mm (top)
Cooling Fan Type
Axial fan motor
Temp. Controller
PID controll by microprocessor
Temp. Setting/Display Method
Digital setting by▲/▼ keys / Digital display
Operation Function
Fixed temperature, quick auto stop, auto stop, auto start, program (maximum 6 patterns: 30 steps x 1 pattern, 15 steps x 2 patterns or 10 steps x 3 patterns)
Additional Functions
Calibration off-set, power failure compensation, lock, RS485 communication interface
Timer
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs.
Safe Device
Self diagnostic (memory error, heater disconnection, sensor error, SSR short curcuit), Electric leakage breaker, Overheat prevention device
Internal Dimensions WxDxH
100×250×150 mm
External Dimensions WxDxH
346×505×567 mm
Internal Capacity
3.75L
Power Source (50/60Hz)
AC115V 14.5A AC220V 7.5A
Weight
~30kg
Accessories
Exhaust port cap 1 pc.

Product description

Microprocessor-controlled 3.75L muffle furnace, ±2°C accuracy, max 1150°C, with communication port.

Yamato FO-210CR Muffle Furnace

  • Operating Temperature Range: 100 to 1150°C
  • Temperature Control Accuracy: ±2°C at 1150°C
  • Maximum Temperature Reaching Time: Approximately 60 minutes
  • Internal Capacity: 3.75 liters
  • Internal Dimensions (WxDxH): 100 × 250 × 150 mm
  • External Dimensions (WxDxH): 346 × 505 × 567 mm
  • Power Source: AC 220V 7.5A (also support AC115V 14.5A)
  • Weight: Approximately 30 kg
  • Construction:
  • Exterior: Cold rolled steel plate with baked-on melamine resin finish
  • Internal: Ceramic fiber insulation
  • Heating Element: Iron-chrome wire, 1.5 kW
  • Sensor: R-type thermocouple for long life and reliable temperature measurement
  • Controller: Microprocessor-based PID controller with digital display and ▲/▼ keys
  • Program Functionality:
  • Up to 6 programs
  • Configurations: 30 steps × 1 pattern, 15 steps × 2 patterns or 10 steps × 3 patterns
  • Operation Modes: Fixed temperature, quick auto stop, auto stop, auto start, and programmable sequences
  • Safety Features:
  • Self-diagnostic functions (memory error, heater disconnection, sensor error, SSR short circuit)
  • Calibration offset
  • Lock function
  • Auto recovery after power failure
  • Earth leakage breaker
  • Automatic overheat prevention device
  • Additional Options (selectable): Exhaust system unit, nitrogen gas loading device with flow meter, temperature and alarm output terminals, sample tray
  • Exhaust Port: Ø20 mm located on top, includes exhaust port cap accessory
  • Cooling System: Axial fan motor for chamber cooling
  • Communication Interface: RS485 communication port for data exchange and control integration

This unit is designed for applications including glass fusing, enamel coating, ceramics processing, metal soldering and brazing, alloying, fusion, heat treatment, melting, annealing, metallurgy, mining, environmental testing, pharmaceutical development, and general R&D.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026