Circulation Method
Forced convection + Natural convection
External Temp. Range
5~35°C
Temperature Set Range
0~130°C (Wind velocity: 0), 0~270°C (Wind velocity: 1~10)
Temperature Control Range
RT +25~120°C (Wind velocity: 0), RT +15~260°C (Wind velocity: 1~10)
Temp. Control Accuracy *¹
±0.3°C (at 260°C)
All 38 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 38

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced convection + Natural convection
External Temp. Range
5~35°C
Temperature Set Range
0~130°C (Wind velocity: 0), 0~270°C (Wind velocity: 1~10)
Temperature Control Range
RT +25~120°C (Wind velocity: 0), RT +15~260°C (Wind velocity: 1~10)
Temp. Control Accuracy *¹
±0.3°C (at 260°C)
Temp. Fluctuation *¹
±0.5°C (at 260°C)
Temp. Distribution Precision *¹
±2.5°C (at 260°C)
Temp. Gradient *¹
8°C (at 260°C)
Temp. Rise Time *¹
100min.
Chamber / Exterior / Insulation
Stainless steel / Cold rolled steel paneling, chemical-proof baked-on finish / Glass wool
Door
Single swing(left side)
Heater (Stainless Steel Tube)
0.83kWx2
Wind Velocity Adjusting System
10 steps (600~1500rpm) + Wind velocity (0)
Damper
Circulation-Ventilation Manual switching: Interlocked intake and exhaust system (Complete exhaust applicable / Unable to reach 260°C with damper fully open)
Cable Port
Inner diameter: 33mm×1 (right side)
Exhaust Port
Outer diameter: 50mm×1 (back side)
Inlet Port
Inner diameter: 33mm×1 (right side)
Controller
Model V type
Temperature Control / Setting System
PID Z control / Digital setting with ▲/▼ keys
Temperature Display System
Temperature reading display: green 4-digit digital LED/Temperature setting display: orange 5-digit digital LED
Other Indications
LED indicates temperature patterns for heating/stabilizing/cooling
Timer
Fixed temperature operation, Program operation (maximum 99 steps or 99 patterns, with repeat operation function), Timer or clock operation function (Fixed temperature operation w/ auto start/auto stop/quick auto stop, program operation auto start)
Additional Functions
Variable Air Flow Function, Power-on Time and Operation Time Accumulation Monitor (up to 65,535 hours); Calibration Offset; Monitoring Display for Accumulated Power Consumption, Total CO 2 Emissions, and Heater Operation Output; Power Recovery Mode; Setting Data Backup and Recovery
Temperature Sensor
K type Thermocouple double sensor (for temperature control and independent overheat prevention device)
Heater Control
Triac with Zero-cross Control
Control Board
Self-diagnostic Functions (Detection for Temp. Sensor Failure, TRIAC Short Circuit, Automatic overheating prevention, Heater Line Disconnect, Main Relay Contact Damage ), Earth leakage breaker, Fan Motor Failure, Key Lock Function, Independent overheating prevention device
Earth Leakage Breaker
Leak Current/Short Circuit/Over-current Protection, Rated Current Sensitivity 30mA
Door Switch
Door open: fan motor and heater circuit OFF, Door close: fan motor and heater circuit ON
Internal Dimensions (W×D×H Mm)*²
600×500×500
External Dimensions (W×D×H Mm)*²
730×695×940
Capacity
150L
Weight
90kg
Number Of Shelf Bracket Step / Pitch
13 steps/30mm
Withstand Load Of Shelf
15kg/shelf
Power Supply V±10% 50/60Hz Single Phase
AC115V 15A (with plug) AC220V 8A (no plug, round terminal)
Shelf Plate / Bracket
2 pcs. / 4 pcs.

Product description

Programmable 150L forced convection oven with dual circulation, PID control, adjustable airflow, and 99-step program.

Performance and Functions

  • Two circulation types in one unit: forced and natural convection
  • Eco-oven with improved air velocity control and adjustable damper
  • Energy-saving program to reduce power consumption
  • High heat tightness and chamber insulation with excellent dust tightness
  • Air velocity adjustable digitally in 10 increments (600–1500 rpm) plus off position
  • 99-step programmable operation with repeat, auto start/stop, and quick stop functions
  • Adjustable front damper to optimize operation
  • Fluorescent display with interactive input and calibration offset

Specifications

  • Circulation: Forced convection + natural convection
  • External Temp. Range: 5 to 35°C
  • Temperature Set Range: 0-130°C (wind velocity 0), 0-270°C (wind velocity 1–10)
  • Control Range: RT +25 to 120°C (wind velocity 0), RT +15 to 260°C (wind velocity 1-10)
  • Control Accuracy: ±0.3°C at 260°C
  • Fluctuation: ±0.5°C at 260°C
  • Distribution Precision: ±2.5°C at 260°C
  • Temperature Gradient: 8°C at 260°C
  • Rise Time: 100 minutes
  • Chamber Material: Stainless steel
  • Exterior: Cold rolled steel with chemical-proof baked finish
  • Insulation: Glass wool
  • Door: Single swing (left side)
  • Heaters: 2 × 0.83 kW stainless steel tube
  • Wind Velocity: 10 steps + off (600–1500 rpm)
  • Damper: Manual circulation-ventilation switching, interlocked intake/exhaust
  • Ports: Cable port Ø33 mm (right side), Exhaust port Ø50 mm (back side), Inlet port Ø33 mm (right side)
  • Controller Model: V type with PID Z control
  • Display: Green 4-digit LED temperature reading, orange 5-digit temperature setting
  • Indicators: Heating, stabilizing, cooling LED signals
  • Timer: Fixed temperature, program operation (max 99 steps/patterns), clock functions
  • Additional Functions: Variable airflow, power-on/operation time monitor (65,535 h), calibration offset, power consumption/CO2 emissions monitoring, power recovery, data backup/recovery
  • Sensors: K-type thermocouple double sensor for temperature control and overheat prevention
  • Heater Control: Triac with zero-cross control
  • Self-diagnostics: Temperature sensor failure, TRIAC short circuit, overheating prevention, heater line disconnect, relay damage, earth leakage, fan motor failure, key lock
  • Safety: Earth leakage breaker rated at 30mA sensitivity
  • Door Switch: Fan and heater off when door open; on when door closed
  • Internal Dimensions (W×D×H): 600 × 500 × 500 mm
  • External Dimensions (W×D×H): 730 × 695 × 940 mm
  • Capacity: 150 L
  • Weight: 90 kg
  • Shelves: 2 plates, 4 brackets; 13 steps with 30 mm pitch
  • Shelf Load: 15 kg per shelf
  • Power Supply: AC115 V 15 A (with plug) or AC220 V 8 A (without plug)

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026