Circulation Method
Forced air circulation
External Temp. Range
5~35°C
Operating Temp. Range
RT+15°C to 210°C
Temp. Control Accuracy*¹
±0.5°C (at 210°C)
Temp. Distribution Accuracy*¹
±2.0°C (at 210°C)
All 35 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 35

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced air circulation
External Temp. Range
5~35°C
Operating Temp. Range
RT+15°C to 210°C
Temp. Control Accuracy*¹
±0.5°C (at 210°C)
Temp. Distribution Accuracy*¹
±2.0°C (at 210°C)
Temp. Gradient*¹
8°C (at 210°C)
Temp. Rise Time*¹
~45 min.
Chamber / Exterior / Insulation
Stainless steel / Chrome-free electro-galvanized steel plate, chemical-proof baked-on finish / Glass wool
Door
Single swing (left side)
Fan Type
Scirocco fan, Capacitor motor
Fan Motor
30W
Exhaust Port
33mm I.D. 2pcs. (rear)
Observation Window
Optional
Temp. Controller
PID Z control by microprocessor
Temp. Setting Method
Digital setting by ▲/▼ key
Temp. / Info Display
Green 4 digit LED digital display (top screen) and orange 5 digit LED digital display (bottom screen) (1°C resolution)
Timer
1 min. and 99 Hrs. 59 mins: duration operation, 24 hour setting: time operation
Operation Function
Fixed temperature, Program operation (max.99 steps, up to 99 patterns repeat operationing function), Duration/time select timer operationfunction (fixed temperature operation, auto-start, auto-stop, quick auto stop, program operation auto start)
Additional Functions
Power on and Integration time function (up to 65,535 hours), Calibration offset, Time display, Display of power consumption, CO2 discharge andheater operation, Power failure return mode, User configuration information
Heater Circuit Control
Triac zero-cross control
Sensor
K-thermocouple double sensor (for temperature control and independent overheat prevention device)
Safety Device
Self diagnostic functions (temp. sensor abnormal, Heater disconnection, SSR- short, Main relay abnormal, Automatic overheating prevention), Key lock function, Independent overheat prevention, Electric leakage breaker with over current protection
Earth Leakage Breaker
Leak Current/Short Circuit/Over-current Protection, Rated Current Sensitivity 30mA
Independent Overheat Prevention
Set temperature range: 0~250°C
Internal Dimensions*² W×D×H
600×500×1000mm
External Dimensions*² W×D×H
730×695×1660mm
Internal Capacity
300L
Shelf Plate With Standard Load
~15kg/pcs.
Shelf Rest Step Number / Shelf Rest Pitch
29 steps / 30mm
Power Source 50/60Hz
AC220V 11.5A
Weight
~92kg
Shelf Plate
Stainless steel, 1pc on the bottom screwed
Shelf Plate / Bracket
4 pcs. / 8 pcs.

Product description

High-performance 300L forced convection oven with PID control, 210°C max, program operation, and energy-saving design.

The Yamato DNE-811 is an eco-friendly programmable forced convection oven featuring a 300L chamber and powered by 220V.

  • Temperature Control & Accuracy:
  • PID microprocessor Z control
  • Operating range: RT+15°C to 210°C
  • Control accuracy: ±0.5°C at 210°C
  • Distribution accuracy: ±2.0°C at 210°C
  • Temperature gradient: 8°C at 210°C
  • Temperature rise time: ~45 minutes
  • Capacity & Dimensions:
  • Internal dimensions: 600 × 500 × 1000 mm (W×D×H)
  • External dimensions: 730 × 695 × 1660 mm (W×D×H)
  • Internal capacity: 300 L
  • Weight: approx. 92 kg
  • Construction:
  • Chamber: stainless steel
  • Exterior: chrome-free electro-galvanized steel plate with chemical-proof baked finish
  • Insulation: glass wool
  • Door: single swing (left side)
  • Shelf plates: stainless steel, one bottom screwed, 4 pcs. with 8 pcs. brackets
  • Shelf load capacity: ~15 kg per plate, adjustable with 29 steps at 30 mm pitch
  • Heating & Circulation:
  • Two 1.2 kW heaters
  • Forced air circulation via Scirocco fan with 30W capacitor motor
  • Heater circuit control by triac zero-cross method
  • Operation & Functionality:
  • Program operation: up to 99 steps, 99 repeatable patterns
  • Timer: 1 minute to 99 hours 59 minutes duration operation, with 24-hour time operation
  • Multi-mode operation including fixed temperature, auto start/stop, power failure recovery
  • Calibration offset feature
  • Power consumption and CO2 discharge display
  • Data acquisition through cable holes
  • Optional observation window
  • Safety Features:
  • Independent overheat prevention device (set temperature range 0–250°C)
  • Overcurrent circuit breaker with earth leakage (30 mA sensitivity)
  • Self-diagnostic functions for sensor and heater abnormalities
  • Key lock functionality
  • Electric leakage breaker protecting against leak current, short circuit, and overcurrent
  • Additional Features:
  • Power on and integration timer up to 65,535 hours
  • Digital temperature setting with ▲/▼ keys
  • LED digital display with green 4-digit and orange 5-digit panels for temperature and info display

This model is optimized for energy efficiency, reducing power use by approximately 40% compared to prior models and speeding temperature ramp-up by reducing no-load maximum temperature reach time by 15 minutes.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026