53k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Yamato DKN-312C Programmable Forced Air Convection Oven, 27L, 220V

From€2,479.99excl. VAT

In stock

Can't find what you're looking for?

Circulation Method
Forced air circulation
Operating Temp. Range
Room temp. +10°C~260°C
Temp. Adjustment Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
~90 min.
All 33 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 33

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced air circulation
Operating Temp. Range
Room temp. +10°C~260°C
Temp. Adjustment Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
~90 min.
Interior/Exterior Material
Stainless steel / Cold rolled steel plate with melamine resin baking finish
Heat Insulating Material
Glass wool
Heater
SUS pipe heater/1.2kW
Fan Type / Fan Motor
Scirocco fan, Condenser type motor 10W
Cable Hole
30mm I.D. (on the right side) 1pc.
Exhaust Port
30mm I.D. x 2 (on top)
Observation Window
180×180mm Chemical strengthening glassx3
Temp. Controller
3 patterns program controller, PID control by microprocessor
Temp. Setting Method
Digital setting by ▲/▼ key
Temp. Display
Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED
Timer
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. with timer wait function
Operation Function
Fixed temperature operation, Program operation, Auto start, Auto stop, Quick Auto-stop
Program Mode
Program operation : 3 patterns, 30 steps (30 steps×1, 15 steps×2, 10 steps×3) Pattern repeat function
Additional Functions
Calibration off-set function, Key lock, Uninterruptible power for memory
Heater Circuit Control
SSR control
Sensor
K-thermocouple
Safety Device
Self diagnostic functions (temp. sensor abnormal, Heater disconnection, SSR- short, Automatic overheating prevention), Key lock function, Overheat prevention, Electric leakage breaker with over current protection
Internal Dimensions W×D×H
300×300×300 mm
External Dimensions W×D×H
410×451×670 mm
Internal Capacity
27L
Shelf Plate With Standard Load
~15kg/piece
Shelf Rest Step Number / Shelf Rest Pitch
9 steps / 30mm
Power Source 50/60Hz
220V 4.5A
Weight
~35kg
Shelf Plate
Stainless steel, 1pc on the bottom screwed (DKN912C, 2 pcs)
Shelf Plate / Bracket
2 pcs. / 4 pcs.

Product description

Programmable 27L forced air convection oven with PID control, ±1°C accuracy, safety diagnostics, and 220V power.

Yamato DKN-312C Programmable Forced Air Convection Oven

  • Capacity: 27L internal volume
  • Temperature Range: Room temperature +10°C to 260°C
  • Temperature Accuracy:
  • Adjustment accuracy: ±1°C at 210°C
  • Distribution accuracy: ±2.5°C at 210°C
  • Heating: SUS pipe heater, 1.2 kW power
  • Circulation: Forced air using Scirocco fan and 10W condenser motor
  • Controller:
  • Microprocessor-based PID control with 3 pattern program controller
  • 30-step programming with repeat functions
  • Digital setting via ▲/▼ keys
  • Display:
  • Green LED for measurement temperature
  • Red LED for set temperature
  • Operation Modes: Fixed setting, quick auto stop, auto stop, auto start, programmable operation
  • Safety Features:
  • Self-diagnostic (temperature sensor abnormality, heater disconnection, SSR short-circuit)
  • Automatic overheating prevention
  • Electric leakage breaker with over current protection
  • Key lock function
  • Construction:
  • Interior: Stainless steel
  • Exterior: Cold rolled steel plate with melamine resin baking finish
  • Heat insulation: Glass wool
  • Dimensions:
  • Internal: 300 × 300 × 300 mm
  • External: 410 × 451 × 670 mm
  • Additional Features:
  • Observation windows (3 × 180×180 mm chemical-strengthened glass)
  • Built-in exhaust ports (2 × 30 mm I.D. on top)
  • Cable hole (30 mm I.D. on right side)
  • Shelf plate stainless steel (1 piece in bottom), load about 15 kg per shelf
  • Memory backup with uninterruptible power
  • Power Supply: 220V, 4.5A, 50/60 Hz
  • Weight: approx. 35 kg

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 31 October 2026