The system operates on 120/230/240 VAC, 50/60 Hz, single-phase power supply. The instrument power circuit supports 120/230 VAC at 50/60 Hz with a full load current of 4.3 A (120 VAC) and 2.3 A (230 VAC). The motor power circuit supports 120/230 VAC at 50/60 Hz with a full load current of 11.5 A (120 VAC) and 6.0 A (230 VAC). Main fuses are rated at 15 A for both instrument and motor power. The system includes a touchscreen interface with a Wonderware Historian Client Trend software version 17.5.101, build date June 12, 2020. The control panel is an Optek Control 8000 unit. The system is equipped with multiple single-use valves, flow meters, and sensors integrated into the fluid path. The electrical control panel is manufactured by ARTESYN® BioSolutions Estonia. The system is certified by Intercontec and CE marked. The system is designed for single-use chromatography applications in bioprocessing.
Technical Data
Model: Single Use Chromatography System Serial Number: 21001 Voltage: 120/230/240 VAC Frequency: 50/60 Hz Power Consumption: N/A Fuse Rating: 15 A Software Version: Wonderware Historian Client Trend 17.5.101 Configuration: Integrated touchscreen control panel, Optek Control 8000, multiple single-use valves and sensors, flow meters, fluid handling manifold, stainless steel enclosure on casters Manufacturing Year: 2021
Voltage
120/230/240 VAC
Frequency
50/60 Hz
Power Consumption
N/A
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
TangenX
New/Used
Used
Description
The system operates on 120/230/240 VAC, 50/60 Hz, single-phase power supply. The instrument power circuit supports 120/230 VAC at 50/60 Hz with a full load current of 4.3 A (120 VAC) and 2.3 A (230 VAC). The motor power circuit supports 120/230 VAC at 50/60 Hz with a full load current of 11.5 A (120 VAC) and 6.0 A (230 VAC). Main fuses are rated at 15 A for both instrument and motor power. The system includes a touchscreen interface with a Wonderware Historian Client Trend software version 17.5.101, build date June 12, 2020. The control panel is an Optek Control 8000 unit. The system is equipped with multiple single-use valves, flow meters, and sensors integrated into the fluid path. The electrical control panel is manufactured by ARTESYN® BioSolutions Estonia. The system is certified by Intercontec and CE marked. The system is designed for single-use chromatography applications in bioprocessing.
Technical Data
Model: Single Use Chromatography System Serial Number: 21001 Voltage: 120/230/240 VAC Frequency: 50/60 Hz Power Consumption: N/A Fuse Rating: 15 A Software Version: Wonderware Historian Client Trend 17.5.101 Configuration: Integrated touchscreen control panel, Optek Control 8000, multiple single-use valves and sensors, flow meters, fluid handling manifold, stainless steel enclosure on casters Manufacturing Year: 2021
Voltage
120/230/240 VAC
Frequency
50/60 Hz
Power Consumption
N/A
Fuse Rating
15 A
Software Version
Wonderware Historian Client Trend 17.5.101
Configuration
Integrated touchscreen control panel, Optek Control 8000, multiple single-use valves and sensors, flow meters, fluid handling manifold, stainless steel enclosure on casters
Manufacturing Year
2021
Accessories
Integrated touchscreen computer with keyboard, Optek Control 8000 panel, Multiple single-use valve manifolds, Flow meters and sensors, Boot and backup USB sticks
Dimensions
Approximately 48 inches (length) x 30 inches (width) x 66 inches (height)
Weight
Approximately 650 lbs

Product description

Automated single-use chromatography system with integrated control and advanced fluid handling for bioprocessing.

The Repligen ARTeSYN Automated Single-Use Chromatography System is engineered for precise and scalable bioprocessing applications, particularly in molecular diagnostics and biopharmaceutical production pipelines. Key features include:

  • Automated single-use chromatography for reducing contamination risks and increasing process efficiency
  • Integrated touchscreen control system enabling intuitive process monitoring and adjustments
  • Advanced fluid handling capabilities with multiple valves and sensors for accurate flow control and real-time data acquisition
  • Designed to support bioprocessing workflows including purification steps critical in gene editing, synthetic biology, and biomanufacturing
  • Suitable for implementation in cell culture downstream processing, ensuring reproducible performance in molecular cloning workflows
  • Enhances process automation, making it widely adopted in biotechnology research and clinical diagnostics environments requiring robust chromatography solutions

This system optimizes single-use chromatography steps, supporting high-throughput and flexible bioprocessing in modern biotechnology laboratories.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026