51k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

IKA C-MAG HS 7 Control Magnetic Hotplate Stirrer

NewIKAStirrersUnited States

From€1,008.75excl. VAT

In stock

Can't find what you're looking for?

Number of stirring positions
1
Stirring quantity max. per stirring position (H2O)
20 l
Motor rating output
9 W
Direction of rotation
right / left
Speed display set-value
LCD
All 53 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 53

Brands
IKA
New/Used
New
Number of stirring positions
1
Stirring quantity max. per stirring position (H2O)
20 l
Motor rating output
9 W
Direction of rotation
right / left
Speed display set-value
LCD
Speed display actual-value
LCD
Speed control
Turning knob
Speed range
50 - 1500 rpm
Setting accuracy speed
10 rpm
Stirring bar length
30 - 80 mm
Self-heating of the set-up plate by max. stirring (RT:22°C/duration:1h)
1 +K
Heat output
1000 W
Temperature display set-value
LCD
Temperature display actual-value
LCD
Temperature unit
°C
Heating temperature range
room temp. - 500 °C
Heat control
Turning knob
Display resolution
1 K
Temperature setting range
0 - 500 °C
Temperature setting resolution of heating plate
5 K
Connection for ext. temperature sensor
PT1000, ETS-D5, ETS-D6
Temperature setting resolution of medium
1 K
Adjustable safety circuit
100 - 650 °C
Set-up plate material
ceramic
Set-up plate dimensions
180 x 180 mm
Automatic reverse rotation
yes
Intermittent mode
yes
Viscosity trend measurement
yes
Timer
yes
Timer display
LCD
Time setting min.
1 s
Time setting max.
143940 min
Sensor in medium detection (Error 5)
yes
Temperature measure range PT1000
-10 - 350 °C
Speed deviation (no load,nominal voltage, at 1500rpm + 25 °C)
2 ±%
Heating rate (1l H2O in H1500)
5 K/min
Heat control accuracy of heating plate (at 100°C)
5 ±K
Heat control accuracy with ext. PT1000 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
0.5 ±K
Heat control accuracy with ETS-D5 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
0.5 ±K
Heat control accuracy with ETS-D6 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)
0.2 ±K
Dimensions (W x H x D)
220 x 88 x 354 mm
Weight
4 kg
Permissible ambient temperature
5 - 40 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 21
RS 232 interface
yes
USB interface
yes
Voltage
220 - 230 / 115 / 100 V
Frequency
50/60 Hz
Power input
1020 W
Power input standby
2 W

Product description

High-performance hotplate stirrer with 1000 W heat output, LCD controls, and advanced temperature features.

IKA C-MAG HS 7 Control Magnetic Hotplate Stirrer

Speed Range 50-1500 RPM Setting Accuracy Speed 10 rpm Heat Output 1000 W

Features

  • The IKA C-Mag HS 7 control features a durable ceramic square top, suitable for stirring up to 20l (H2O) at speeds from 50 to 1500rpm, ensuring versatility.
  • With a lifetime warranty, IKA stands firmly behind its C-Mag HS 7 control, allowing scientists to focus on their research without concerns about reliability.
  • Regular firmware updates ensure the C-Mag HS 7 control remains cutting-edge, enhancing its functionality and reliability for sensitive experiments.
  • The package includes the PT 1000.60 temperature sensor and IKAFLON® magnetic stirring bars, providing a comprehensive solution for various stirring needs.
  • Featuring an LCD for accurate speed and temperature control, the C-Mag HS 7 control offers precise settings to meet the demands of any experiment.
  • The IKA SmartTemp® function offers intelligent protection, ensuring safe operation by adapting to the user’s needs and experiment parameters.
  • Accessories such as a screwdriver, USB cable, and power cord are included, along with a 2-year manufacturer warranty, highlighting IKA’s commitment to quality.

The IKA C-Mag HS 7 control has a square top made of ceramic. It stirs volumes of up to 20l (H2o) and runs at speeds ranging from 50-1500rpm. IKA’s stands strongly by its product and technology and is offering a lifetime warranty for this product – scientists can focus on their experiments using a reliable hotplate stirrer. IKA not only focuses on hardened glass because of visibility, chemical resistance and safety, it also optically changes the game of a magnetic stirrer with a glass surface. The C-Mag HS 7 control improves over time with regular firmware updates – control of kinetics and sensitive reactions are supported by the integrated timer and counter function – the IKA SmartTemp® function protects user intelligently. PT1000 temperature sensor included.

Click Here to View Product Video

INCLUDED: The IKA C-MAG HS 7 Control Magnetic Hotplate Stirrer includes:

  • C-MAG HS 7 control
  • PT 1000.60 Temperature sensor, stainless steel
  • IKAFLON® 30 Magnetic stirring bar
  • IKAFLON® 40 Magnetic stirring bar
  • Screw driver
  • USB cable
  • Power Cord
  • Operator's Guide
  • Manufacturer's Documentation
  • 2 Year Manufacturer Warranty (+ Additional Free 8 Year Warranty Extension with IKA Registration)

IKA C-MAG HS 7 Control Magnetic Hotplate Stirrer Specifications Number of stirring positions1Stirring quantity max. per stirring position (H2O)20 lMotor rating output9 WDirection of rotationright / leftSpeed display set-valueLCDSpeed display actual-valueLCDSpeed controlTurning knobSpeed range50 - 1500 rpmSetting accuracy speed10 rpm Stirring bar length30 - 80 mm Self-heating of the set-up plate by max. stirring (RT:22°C/duration:1h)1 +K Heat output1000 WTemperature display set-valueLCDTemperature display actual-valueLCDTemperature unit°CHeating temperature rangeroom temp. - 500 °CHeat controlTurning knobDisplay resolution1 KTemperature setting range0 - 500 °CTemperature setting resolution of heating plate5 KConnection for ext. temperature sensorPT1000, ETS-D5, ETS-D6Temperature setting resolution of medium1 KAdjustable safety circuit100 - 650 °CSet-up plate materialceramicSet-up plate dimensions180 x 180 mmAutomatic reverse rotationyesIntermittent modeyesViscosity trend measurementyesTimeryesTimer displayLCDTime setting min.1 sTime setting max.143940 minSensor in medium detection (Error 5)yesTemperature measure range PT1000-10 - 350 °CSpeed deviation (no load,nominal voltage, at 1500rpm + 25 °C)2 ±%Heating rate (1l H2O in H1500)5 K/minHeat control accuracy of heating plate (at 100°C)5 ±KHeat control accuracy with ext. PT1000 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)0.5 ±KHeat control accuracy with ETS-D5 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)0.5 ±KHeat control accuracy with ETS-D6 (500ml H2O in 600ml beaker,40mm stirring bar,600rpm,50°C)0.2 ±KDimensions (W x H x D)220 x 88 x 354 mmWeight4 kgPermissible ambient temperature5 - 40 °CPermissible relative humidity80 %Protection class according to DIN EN 60529IP 21RS 232 interfaceyesUSB interfaceyesVoltage220 - 230 / 115 / 100 VFrequency50/60 HzPower input1020 WPower input standby2 WComparison of ModelsSpecificationsC-MAG HS 10 DigitalC-MAG HS 10C-MAG HS 4 DigitalC-MAG HS 4C-MAG HS 7 ControlC-MAG HS 7 Control PackageC-MAG HS 7 DigitalC-MAG HS 7C-MAG HS 7 PackageTemperature Range (°C)50 to 50050 to 50050 to 50050 to 500Ambient to 500Ambient to 50050 to 50050 to 50050 to 500Speed Range (RPM)100 to 1,500100 to 1,500100 to 1,500100 to 1,50050 to 1,50050 to 1,500100 to 1,500100 to 1,500100 to 1,500Heat Output (W)1500150025025010001000100010001000Platform Dimensions (mm)260 x 260260 x 260100 x 100100 x 100180 x 180180 x 180180 x 180180 x 180180 x 180Dimensions (W x H x D) (mm)300 x 105 x 415300 x 105 x 415150 x 105 x 260150 x 105 x 260220 x 88 x 354220 x 88 x 354215 x 105 x 330220 x 105 x 335220 x 105 x 335.comparison-table tr td:nth-child(6) { background-color: #fffacd; }

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 14 November 2026