Number of stirring positions
1
Stirring quantity max. per stirring position (H2O)
10 l
Motor rating output
1.5 W
Direction of rotation
left
Speed control
scale 0 - 6
All 29 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 29

Brands
IKA
New/Used
New
Number of stirring positions
1
Stirring quantity max. per stirring position (H2O)
10 l
Motor rating output
1.5 W
Direction of rotation
left
Speed control
scale 0 - 6
Speed range
100 - 1500 rpm
Stirring bar length max.
80 mm
Self-heating of the set-up plate by max. stirring (RT:22°C/duration:1h)
1 +K
Heat output
1000 W
Temperature display set-value
LED
Temperature display actual-value
LED
Heating temperature range
50 - 500 °C
Heat control
Turning knob
Heating rate heating plate
5 K/min
Temperature setting resolution of heating plate
5 K
Connection for ext. temperature sensor
ETS-D5
Fixed safety circuit
550 °C
Set-up plate material
ceramic
Set-up plate dimensions
180 x 180 mm
Dimensions (W x H x D)
220 x 105 x 335 mm
Weight
5 kg
Permissible ambient temperature
5 - 40 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 21
Voltage
230 / 120 / 100 V
Frequency
50/60 Hz
Power input
1020 W

Product description

Efficient and precise heating stirrer with a ceramic plate for lab applications.

IKA C-MAG HS 7 Magnetic Hotplate Stirrer Package Magnetic stirrer with ceramic heating plate. Bushing according to DIN 12878 for connecting a contact thermometer, e.g. ETS-D5.

Click Here to View Product Video

INCLUDED: The IKA C-MAG HS 7 Magnetic Hotplate Stirrer Package includes:

  • C-MAG HS 7
  • ETS-D5
  • H 16 V Support rod
  • H 44 Boss head clamp
  • H 38 Holding rod
  • Power Cord
  • Operator's Guide
  • Manufacturer's Documentation
  • 2 Year Manufacturer Warranty ( + Additional Free 1 Year Warranty Extension with IKA Registration)

IKA C-MAG HS 7 Magnetic Hotplate Stirrer Package Specifications Number of stirring positions1Stirring quantity max. per stirring position (H2O)10 lMotor rating output1.5 WDirection of rotationleftSpeed controlscale 0 - 6Speed range100 - 1500 rpmStirring bar length max.80 mmSelf-heating of the set-up plate by max. stirring (RT:22°C/duration:1h)1 +KHeat output1000 WTemperature display set-valueLEDTemperature display actual-valueLEDHeating temperature range50 - 500 °CHeat control Turning knobHeating rate heating plate 5 K/minTemperature setting resolution of heating plate 5 KConnection for ext. temperature sensorETS-D5Fixed safety circuit550 °CSet-up plate materialceramicSet-up plate dimensions180 x 180 mmDimensions (W x H x D)220 x 105 x 335 mmWeight5 kgPermissible ambient temperature5 - 40 °CPermissible relative humidity80 %Protection class according to DIN EN 60529IP 21Voltage230 / 120 / 100 VFrequency50/60 HzPower input1020 WComparison of ModelsSpecificationsC-MAG HS 10 DigitalC-MAG HS 10C-MAG HS 4 DigitalC-MAG HS 4C-MAG HS 7 ControlC-MAG HS 7 Control PackageC-MAG HS 7 DigitalC-MAG HS 7C-MAG HS 7 PackageTemperature Range (°C)50 to 50050 to 50050 to 50050 to 500Ambient to 500Ambient to 50050 to 50050 to 50050 to 500Speed Range (RPM)100 to 1,500100 to 1,500100 to 1,500100 to 1,50050 to 1,50050 to 1,500100 to 1,500100 to 1,500100 to 1,500Heat Output (W)1500150025025010001000100010001000Platform Dimensions (mm)260 x 260260 x 260100 x 100100 x 100180 x 180180 x 180180 x 180180 x 180180 x 180Dimensions (W x H x D) (mm)300 x 105 x 415300 x 105 x 415150 x 105 x 260150 x 105 x 260220 x 88 x 354220 x 88 x 354215 x 105 x 330220 x 105 x 335220 x 105 x 335.comparison-table tr td:nth-child(10) { background-color: #fffacd; }

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 5 November 2026