Upper measuring limit in mbar/hPa
1080 mbar
Upper measuring limit in torr
810 torr
Lower measuring limit in mbar/hPa
0.1
Lower measuring limit in torr
0.1 torr
Measurement principle
Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
All 32 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 32

Brands
Vacuubrand
New/Used
New
Upper measuring limit in mbar/hPa
1080 mbar
Upper measuring limit in torr
810 torr
Lower measuring limit in mbar/hPa
0.1
Lower measuring limit in torr
0.1 torr
Measurement principle
Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement
< +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Vacuum sensor
VACUU·SELECT Sensor
Temperature coefficient
< 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection
Hose nozzle DN 6/10 mm
Venting valve
Integrated, hose nozzle DN 4-5 mm
Lower ambient temperature (storage)
-10 °C
Upper ambient temperature (storage)
60 °C
Lower ambient temperature (operation)
10 °C
Upper ambient temperature (operation)
40 °C
Max. media temperature for continuous operation
40 °C
Max. media temperature short term
80 °C
Material of outer housing
Robust plastic housing with good chemical resistance
Protection class IEC 60529
IP 40
Protection class UL50E
Type 1
Protection class front side IEC 60529
IP 41
Protection class UL50E front side
Type 2
Dimension L in mm
191 mm
Dimension B in mm
127 mm
Dimension H in mm
187 mm
Weight
2 kg
Max. current for VACUU BUS (24V DC)
4 A
Cable length connection in m
2 m
Interface
Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)
NRTL certification
Yes
Items supplied
VACUU·SELECT complete controller bench-top device, with solenoid valve, non-return valve, integrated ceramic diaphragm vacuum sensor and venting valve. With power supply, ready to use, with manual.

Product description

Advanced benchtop controller for precise vacuum management.

VACUUBRAND VACUU-Select Complete Benchtop Controller

Upper Measuring Limit 810 torr Lower Measuring Limit 0.1 torr Accuracy Less than +/- 1 mbar/hPa/torr

Features

  • Supplied complete and ready for use, including integrated valve and common hose connections
  • Predefined vacuum applications and automatic boiling point detection saves time
  • Simple setup - connect VACUU·SELECT in-line between pump and vacuum application
  • Integrated vent valve allows inert gas connection
  • Integrated check valve minimizes interaction with other applications on the same vacuum supply

The VACUU·SELECT complete controller provides enhanced process efficiency to applications supported by a vacuum source such as a basic pump or a powerful vacuum network. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run pre-defined applications at the touch of a button, or create your own application with simple drag-and-drop editing. The controller is available as a benchtop unit, ready for mounting on lab scaffolding, or as a built-in version for lab casework. The integrated controller includes the VACUU·SELECT vacuum controller, a check valve, and a chemical-resistant solenoid isolation valve. The ceramic vacuum sensor and venting valve are built right into the body of the VACUU·SELECT controller. The compact unit is easy to install and setup. With its intuitive, application-based interface, the controller offers predefined vacuum processes for all common laboratory applications. In the case of solvent evaporation, it detects the boiling pressure and then holds the pressure level stable using two-point control.INCLUDED: The VACUUBRAND VACUU-Select Complete Benchtop Controller includes:

  • VACUU·SELECT complete controller bench-top device
  • Solenoid valve
  • Non-return valve
  • Integrated ceramic diaphragm vacuum sensor
  • Venting valve
  • Power supply
  • Operator's Manual
  • Manufacturer's Documentation
  • 2 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026