Circulation Method
Natural convection
Operating Temp. Range
Room temp.+5 to 260°C
Temp. Control Accuracy
±1.0°C (at 260°C)
Temp. Distribution Accuracy
±5.0°C (at 260°C)
Max. Temp. Reaching Time
90 min. (Room temp. +5°C to 260°C)
All 32 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 32

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Natural convection
Operating Temp. Range
Room temp.+5 to 260°C
Temp. Control Accuracy
±1.0°C (at 260°C)
Temp. Distribution Accuracy
±5.0°C (at 260°C)
Max. Temp. Reaching Time
90 min. (Room temp. +5°C to 260°C)
Interior Material
Stainless steel
Exterior Material
Cold rolled steel plate with melamine resin baking finish
Heat Insulating Material
Glass wool
Heater
Stainless pipe heater / 1.36kW
Observation Window
250×280 mm Chemically strengthened glass x 3
Cable Hole
30 mm l.D.×1 pcs. (right side)
Exhaust Port
30 mm l.D.×2 pcs. (on top)
Temp. Controller
3 patterns program controller, PID control by microprocessor
Temp. Setting Method
Operation menu key and Digital setting by ▲/▼ key
Temp. Display Method
Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED
Timer
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min.
Operation Function
Fixed temperature operation, Program operation, Auto start, Auto stop, Quick Auto-stop
Program Mode
Program operation: 6 pattern, 30 steps (30 steps×1, 15 steps×2, 10 steps×3)
Additional Functions
Calibration off-set function, Key lock, Uninterruptible power for memory, Pattern repeat function
Heater Circuit Control
SSR control
Sensor
K-thermocouple
Safety Device
Self diagnostic functions (temp. sensor abnormal, Heater disconnection, SSR- short, Memory abnormal, Automatic overheating prevention), Overheat prevention, Electric leakage breaker with over current protection
Internal Dimensions (W×D×Hmm)
600×540×500
External Dimensions (W×D×Hmm)
710×651×870
Internal Capacity
162L
Shelf Plate Load
15kg / pcs.
Shelf Rest Step Number / Pitch
13 steps / 30mm
Power Source 50/60Hz
AC220V 6.5A
Weight
63kg
Shelf Plate / Shelf Bracket
Stainless steel, 2 pcs. / 4 pcs.

Product description

Gravity convection oven with 162L capacity, PID controller, adjustable ramp/soak, safety diagnostics, 220V power supply.

Yamato DVS-612C Gravity Convection Laboratory Oven (220V, 162L capacity)

  • Circulation method: Natural convection
  • Operating temperature range: Room temperature +5°C to 260°C
  • Temperature control accuracy: ±1.0°C at 260°C
  • Temperature distribution accuracy: ±5.0°C at 260°C
  • Maximum temperature reaching time: 90 minutes
  • Interior material: Stainless steel
  • Exterior material: Cold rolled steel plate with melamine resin baking finish
  • Heat insulating material: Glass wool
  • Heater type/power: Stainless pipe heater, 1.36 kW
  • Observation windows: Three chemically strengthened glass windows, 250×280 mm each
  • Cable hole: One, 30 mm inner diameter on right side
  • Exhaust ports: Two, 30 mm inner diameter on top
  • Temperature controller: Microprocessor PID with 6 pattern program controller (30 steps ×1; 15 steps ×2; 10 steps ×3)
  • Temperature setting/display: Digital setting via ▲/▼ keys; measured temp displayed with green LED, set temp with red LED
  • Timer range: 1 minute to 999 hours 50 minutes
  • Operation modes: Fixed temperature, program operation, auto start, auto stop, quick auto-stop
  • Additional features: Calibration offset function, key lock, uninterruptible memory power, pattern repeat function
  • Heater circuit control: SSR (Solid State Relay) control
  • Sensor type: K-type thermocouple
  • Safety features:
  • Self-diagnostic functions including temp sensor abnormality, heater disconnection, SSR short, memory abnormality
  • Automatic overheating prevention
  • Electric leakage breaker with overcurrent protection
  • Dimensions (W×D×H mm):
  • Internal: 600 × 540 × 500
  • External: 710 × 651 × 870
  • Internal capacity: 162 liters
  • Shelf load capacity: 15 kg per shelf
  • Shelf rest steps/pitch: 13 steps with 30 mm pitch
  • Power source: AC 220V, 6.5A, 50/60 Hz
  • Weight: 63 kg
  • Shelves and brackets: Stainless steel, 2 shelves and 4 brackets included

This model is designed for precise temperature control with programmable ramp, soak, and fall times, supported by comprehensive safety and diagnostic features, ideal for standard laboratory thermal processing applications.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 16 November 2026