Circulation Method
Forced air circulation
Operating Temperature Range
Room temp. +10~260°C
Temp. Control Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
90min (at room temp. +10°C~260°C)
All 32 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 32

Brands
Yamato Scientific
New/Used
Used
Circulation Method
Forced air circulation
Operating Temperature Range
Room temp. +10~260°C
Temp. Control Accuracy
±1°C (at 210°C)
Temp. Distribution Accuracy
±2.5°C (at 210°C)
Max. Temp. Reaching Time
90min (at room temp. +10°C~260°C)
Interior Material
Stainless Steel
Exterior Material
Cold rolled steel plate with melamine resin baking finish
Heat Insulating Material
Glass wool
Heater
SUS pipe heater / 1.2kW
Fan Type / Motor
Scirocco fan / Condenser type motor 10W
Cable Port
30 mm l.D.×1 pc. (right side)
Exhaust Port
30 mm l.D.×2 pcs. (the top)
Temp. Controller
PlD control by microprocessor
Temp. Setting Method
Operation menu key and digital setting by ▲/▼ key
Temp Display Method
Measurement temp. : Digital display by green LED / Setting temp. : Digital display by red LED
Timer
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. (with time wait function)
Operation Functions
Fixed temperature operation, Quick Auto-stop, Auto start, Auto stop
Additional Functions
Calibration off-set function, Key lock, Uninterruptible power for memory
Heater Circuit Control
SSR control
Sensor
K-thermocouple
Safety Device
Self diagnostic functions (Sensor trouble detection, Memory error, Measured temperature lower limit error, Measured temperature error), Auto overheat prevention, Independent overheat prevention.
Internal Dimensions W×D×H
450×450×450mm
External Dimensions W×D×H
560×601×820mm
Internal Capacity
90L
Shelf Plate With Standard Load
15kg/piece
Shelf Rest Step Number
9 steps
Shelf Rest Pitch
35mm
Power Source 50/60Hz
AC115V 11A
Weight
50kg
Shelf Plate / Bracket
Stainless steel 2 pcs. / 4 pcs.

Product description

90L forced air convection oven with digital PID control, ±1°C accuracy, and multiple safety features.

Yamato DKL-401C Forced Air Convection Oven

  • Capacity: 90L (3.17 cu ft)
  • Temperature Range: Room temp. +10°C to 260°C
  • Temperature Control: PID microprocessor control with ±1°C accuracy at 210°C
  • Temperature Distribution Accuracy: ±2.5°C at 210°C
  • Heating Element: 1.2 kW SUS pipe heater
  • Circulation: Forced air circulation using Scirocco fan and 10W condenser motor
  • Operation Modes: Fixed temperature, Quick Auto stop, Auto start, Auto stop
  • Control Interface: Digital settings via operation menu keys and ▲/▼ keys
  • Temperature Display: Green LED for measured temperature, Red LED for set temperature
  • Timer: Range from 1 min to 999 Hrs. 50 min with wait function
  • Safety Features:
  • Self-diagnostic (sensor, memory, temperature errors)
  • Auto overheat prevention
  • Independent overheat prevention
  • Additional Functions: Auto recovery after power failure, calibration offset, key lock, uninterruptible power for memory
  • Physical Specifications:
  • Internal Dimensions: 450 × 450 × 450 mm
  • External Dimensions: 560 × 601 × 820 mm
  • Weight: 50 kg
  • Materials:
  • Interior: Stainless steel
  • Exterior: Cold rolled steel with melamine resin finish
  • Insulation: Glass wool
  • Ports:
  • Cable port: 30 mm I.D. (right side) × 1
  • Exhaust ports: 30 mm I.D. × 2 (top)
  • Additional Hardware:
  • Shelf plates: 2 stainless steel plates, load 15 kg each
  • Shelf brackets: 4 pcs, 9 steps with 35 mm pitch
  • Power: AC 115V, 11A, 50/60 Hz
  • Heater Circuit Control: SSR control
  • Sensor Type: K-thermocouple

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026