From€5,084.92excl. VAT
In stock
Can't find what you're looking for?
High-precision drying oven with up to 300°C temperature, ideal for research labs.
IKA Oven 125 Control Drying Oven w/ Glass Door
Heat Output 1500 W Working Temperature room temp. +5 - 300 °C Operating Area Inner chamber 550 x 525 x 450 mm
Features
The models in the IKA Oven 125 dry series are powerful drying cabinets for temperature regulation, drying, ageing and heating tasks. Rapid heating and exact temperature regulation guarantee reproducible results in industrial laboratories, schools and universities, research, quality control or science. Thanks to its high quality insulation, the device has a very large interior of 125 l in relation to its total volume. This structure also reduces odour emissions and operating costs and ensures excellent temperature uniformity.The Oven 125 control dry recirculating air drying cabinet heats up to 300 °C. The additional temperature selection limited TWB (DIN 12880) meets the highest security requirements. Furthermore, the temperature curve can be monitored during testing independently of the safety temperature. This means that your test material is always protected.The glass door allows for better monitoring of your samples.A well thought out interiorThe generously dimensioned interior of the Oven 125 control dry is comfortably illuminated. A practical cable bushing at the rear of the device is provided as standard for measurements in the oven or in the test material. The fan switches off automatically if the door is open. Up to 6 insertable shelves can be accommodated in the interior made of stainless steel.InterfacesThe Oven 125 control dry offers an interface for an additional sensor for direct temperature regulation in the test material. Test parameters can be stored directly on a USB stick.Two displaysAll important process parameters are displayed clearly on two large TFT displays. The temperature profiles and individual user profiles can be entered via the intuitive user interface. The real-time clock enables convenient digital documentation and a time-delayed start.Click Here to View Product Video
INCLUDED: The IKA Oven 125 Control Drying Oven w/ Glass Door includes:
IKA Oven 125 Control Drying Oven w/ Glass Door Specifications Heat output1500 WWorking temperatureroom temp. +5 - 300 °CAdjustable safety circuit50 - 270 °CAdjustment and display resolution0.1 KTemperature stability (150°C, center, standard door)0.5 ±KTemperature displayyesTimeryesTimer displayLCDTime setting range1 - 142560 minNumber of trays max.6Load for one tray max.30 kgOperating area inner chamber550 x 525 x 450 mmTotal volume inner chamber125 l Air outlet port diameter inside48 mm Dimensions (W x H x D)700 x 825 x 650 mmWeight89 kg Permissible ambient temperature5 - 40 °CPermissible relative humidity80 %Protection class according to DIN EN 60529IP 20RS 232 interfaceyesUSB interfaceyesVoltage220 - 240 / 115 / 100 VFrequency50/60 HzPower input1600 WPower input standby2 WComparison of ModelsSpecificationsIKA Oven 125 BasicIKA Oven 125 Basic w/ Glass DoorIKA Oven 125 ControlIKA Oven 125 Control w/ Glass DoorHeat Output1500 W1500 W1500 W1500 WWorking Temperature RangeRoom temp. +5 - 250 °CRoom temp. +5 - 250 °CRoom temp. +5 - 300 °CRoom temp. +5 - 300 °CTimer Display7 segment LED7 segment LEDLCDLCDTime Setting Range1 - 144000 min1 - 144000 min1 - 142560 min1 - 142560 minInner Chamber (WxDxH)550 x 525 x 450 mm550 x 525 x 450 mm550 x 525 x 450 mm550 x 525 x 450 mmTotal Volume Inner Chamber125 L125 L125 L125 LExternal Dimensions (WxHxD)700 x 825 x 650 mm700 x 825 x 650 mm700 x 825 x 650 mm700 x 825 x 650 mmRS 232 InterfaceNoNoYesYesUSB InterfaceYesYesYesYesVoltage220 - 240 / 115 / 100 V220 - 240 / 115 / 100 V220 - 240 / 115 / 100 V220 - 240 / 115 / 100 V.comparison-table tr td:nth-child(5) { background-color: #fffacd; }
Request a Formal Quote
Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.
We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.
We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.
With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.
Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.
Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.
Two to six weeks, depending on refurbishment scope and whether calibration is included.
We ship to 38 countries. Crating and customs handling are quoted with the instrument.
Tell us what you need and a scientist finds it for you, usually within the hour.
Last updated 1 November 2026
€5,085 sits above most furnaces here. The middle half of the 130 with a price runs from €475 to €4,529.