58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

IKA Dry Block Heater 3 Dry block heater, 3 blocks

NewIKAHeating & coolingUnited States

€1,426.13excl. VAT

In stock

Can't find what you're looking for?

Number of blocks
3
Heat output
330 W
Heating temperature range
room temp. +5° - 120 °C
Temperature display
yes
Adjustment and display resolution
1 K
All 27 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 27

Brands
IKA
New/Used
New
Number of blocks
3
Heat output
330 W
Heating temperature range
room temp. +5° - 120 °C
Temperature display
yes
Adjustment and display resolution
1 K
Connection for ext. temperature sensor
CT (DIN12878)
PT 1000 variation;DIN EN 60751 Kl. A
≤ ± (0.15 +0.002xITI) K
Temperature stability within the blocks at 37°C *
±0.2 °C
Temperature stability within the blocks at 60°C *
±0.4 °C
Temperature Homogenity @ 37°C *
0.3 K
Temperature Homogenity @ 60°C *
0.6 K
Heating rate / Heat up time with external sensor *
4 K/min
Set-up plate material
Aluminium alloy
Set-up plate dimensions
96 x 228 mm
Fixed safety circuit
150 °C
Timer
yes
Time setting range
1 - 5999 min
Dimensions (W x H x D)
151 x 73 x 380 mm
Weight
1.7 kg
Permissible ambient temperature
5 - 40 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 21
Voltage
115 V
Frequency
50/60 Hz
Power input
330 W

Product description

Versatile digital block heater with precise temperature control and error displays.

IKA Dry Block Heater 3 Dry block heater, 3 blocks

Number of Blocks 3 Blocks Heating Temp. Range Room Temp. +5°°C to 120°C Setup Plate Material Aluminium Alloy

Features

  • Stepless adjustable temperature up to 120 °C
  • Timer: Countdown, adjustable from 1 min to 99h 59min
  • Counter: Display of heating time
  • Highly versatile with a large number of blocks
  • Error code display
  • Fixed safety circuit
  • Acoustic signal at end of test

Digital block heater for three aluminum blocks provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media test, coagulation test, blood-urea-nitrogen determination and in situ hybridizations.INCLUDED: The IKA Dry Block Heater 3 Dry block heater, 3 blocks includes:

  • Dry Block Heater 3
  • Block remove tool
  • PT 1000.60 Temperature sensor, stainless steel
  • Two Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026