58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Radleys Mya 4 Four-Position Benchtop Bioreactor with Touchscreen and External Temperature Control

Price on request

In stock

Can't find what you're looking for?

Description
Radleys Mya 4 Bioreactor. Serial No.: 46062018. The system includes four reactor stations with mounted overhead drive modules, four glass reactor vessels, four overhead stirrer assemblies, and a touchscreen controller. A recirculating temperature control unit is present. Voltage: 230 V. Frequency: 50 Hz. Phase: N/A. Power consumption: N/A. Fuse rating: 15 A. Software version: N/A. Configuration: four-position bioreactor setup with touchscreen control and temperature control unit. Manufactured: N/A.
Technical Data
Model: Mya 4 Serial Number: 46062018 Voltage: 230 V Frequency: 50 Hz Power Consumption: N/A Fuse Rating: 15 A Software Version: N/A Configuration: Four-position bioreactor system with touchscreen controller, four overhead drive modules, four glass reactor vessels, and recirculating temperature control unit Manufacturing Year: N/A
Voltage
230 V
Frequency
50 Hz
Power Consumption
N/A
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Radleys
New/Used
Used
Description
Radleys Mya 4 Bioreactor. Serial No.: 46062018. The system includes four reactor stations with mounted overhead drive modules, four glass reactor vessels, four overhead stirrer assemblies, and a touchscreen controller. A recirculating temperature control unit is present. Voltage: 230 V. Frequency: 50 Hz. Phase: N/A. Power consumption: N/A. Fuse rating: 15 A. Software version: N/A. Configuration: four-position bioreactor setup with touchscreen control and temperature control unit. Manufactured: N/A.
Technical Data
Model: Mya 4 Serial Number: 46062018 Voltage: 230 V Frequency: 50 Hz Power Consumption: N/A Fuse Rating: 15 A Software Version: N/A Configuration: Four-position bioreactor system with touchscreen controller, four overhead drive modules, four glass reactor vessels, and recirculating temperature control unit Manufacturing Year: N/A
Voltage
230 V
Frequency
50 Hz
Power Consumption
N/A
Fuse Rating
15 A
Software Version
N/A
Configuration
Four-position bioreactor system with touchscreen controller, four overhead drive modules, four glass reactor vessels, and recirculating temperature control unit
Manufacturing Year
N/A
Accessories
Touchscreen controller, Recirculating temperature control unit, Four glass reactor vessels, Four overhead stirrer assemblies, Four mounted reactor stations, Instruction manual
Dimensions
N/A
Weight
N/A

Product description

Four-position benchtop bioreactor system with touchscreen control and recirculating temperature unit for parallel bioprocess development.

The Radleys Mya 4 is a four-position benchtop bioreactor system designed for parallel bioprocess development and laboratory-scale reaction control. Equipped with an integrated touchscreen controller and a dedicated external recirculating temperature control unit, this system ensures precise environmental regulation across multiple reactors simultaneously.

Key features include:

  • Four reactor vessels with overhead drive heads for uniform agitation and mixing.
  • Touchscreen interface enabling intuitive control of bioprocess parameters.
  • External temperature control unit allowing precise temperature regulation essential for cell culture, synthetic biology, and molecular diagnostics research.
  • Voltage compatibility at 230V and frequency support for 50/60Hz operation.
  • Fuse rating of 15A ensuring reliable electrical safety.
  • Inclusion of flow meters allows monitoring of gas or liquid flow for fermentations and other bioprocesses.

This system is widely adopted in biotechnology laboratories for bioprocess optimization, biomanufacturing workflows, and gene editing experiments that demand tightly controlled environmental conditions. The parallel setup supports increased throughput, making it critical for molecular cloning workflows and biopharmaceutical production pipeline testing.

Ideal for researchers in cell engineering, live-cell bioreactor studies, and biomedicine, the Radleys Mya 4 combines precision control with ease of operation, facilitating reproducible and scalable results in biotechnology and molecular biology applications.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026