58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Waters Acquity High-Performance Liquid Chromatography System with Binary Solvent Manager and PDA Detector

UsedWatersHPLC pumpsUnited States

Price on request

In stock

Can't find what you're looking for?

Description
Waters Acquity HPLC system with multiple modules including Binary Solvent Manager (BSM), Sample Manager (SM), Column Heater (CO HTCH), and Photodiode Array Detector (PDA). Voltage: 100-240 V. Frequency: 50/60 Hz. Power consumption and fuse rating are not specified. Software version is not visible. Manufactured: 2009. Serial Numbers: BSM:L09UPB989M, SM:L09UPA554M, CO HTCH:M09UPH062G, PDA:C12UPD937A.
Technical Data
Model: Acquity Serial Number: BSM:L09UPB989M/SM:L09UPA554M/CO HTCH:M09UPH062G/PDA:C12UPD937A Voltage: 100-240 V Frequency: 50/60 Hz Power Consumption: N/A Fuse Rating: N/A Software Version: N/A Configuration: Binary Solvent Manager (BSM), Sample Manager (SM), Column Heater (CO HTCH), Photodiode Array Detector (PDA) Manufacturing Year: 2009
Voltage
100-240 V
Frequency
50/60 Hz
Power Consumption
N/A
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Waters
New/Used
Used
Description
Waters Acquity HPLC system with multiple modules including Binary Solvent Manager (BSM), Sample Manager (SM), Column Heater (CO HTCH), and Photodiode Array Detector (PDA). Voltage: 100-240 V. Frequency: 50/60 Hz. Power consumption and fuse rating are not specified. Software version is not visible. Manufactured: 2009. Serial Numbers: BSM:L09UPB989M, SM:L09UPA554M, CO HTCH:M09UPH062G, PDA:C12UPD937A.
Technical Data
Model: Acquity Serial Number: BSM:L09UPB989M/SM:L09UPA554M/CO HTCH:M09UPH062G/PDA:C12UPD937A Voltage: 100-240 V Frequency: 50/60 Hz Power Consumption: N/A Fuse Rating: N/A Software Version: N/A Configuration: Binary Solvent Manager (BSM), Sample Manager (SM), Column Heater (CO HTCH), Photodiode Array Detector (PDA) Manufacturing Year: 2009
Voltage
100-240 V
Frequency
50/60 Hz
Power Consumption
N/A
Fuse Rating
N/A
Software Version
N/A
Configuration
Binary Solvent Manager (BSM), Sample Manager (SM), Column Heater (CO HTCH), Photodiode Array Detector (PDA)
Manufacturing Year
2009
Accessories
N/A
Dimensions
N/A
Weight
N/A

Product description

Waters Acquity HPLC system featuring modular binary solvent manager, sample manager, column heater, and PDA detector.

The Waters Acquity HPLC system is a modular high-performance liquid chromatography instrument designed for precise, reproducible analytical separations widely utilized in molecular diagnostics and biotechnology workflows. This configuration includes:

  • Binary Solvent Manager (BSM) enabling gradient elution with accurate solvent blending for complex sample matrices
  • Sample Manager (SM) optimized for automated injection and sample handling, crucial for high-throughput analytical pipelines
  • Column Heater (CO HTCH) maintaining stable temperature control essential for reproducible retention times and separation efficiency
  • Photodiode Array Detector (PDA) allowing multi-wavelength detection facilitating detailed spectral analysis and compound identification

Operating at a voltage range of 100–240 V and frequency of 50/60 Hz, this 2009-manufactured system supports critical applications in bioprocessing, synthetic biology, and clinical diagnostics. The Acquity HPLC system is a vital tool for laboratories requiring versatile, high-resolution chromatographic separations, particularly essential for molecular cloning workflows and biopharmaceutical production pipelines. Serial numbers associated with each module ensure traceability and maintenance documentation.

This HPLC setup is widely adopted in biotechnology research for its ability to deliver sensitive, reproducible results in chromatographic analysis of proteins, nucleotides, metabolites, and small molecules. Its integration of advanced solvent management and detection modules supports demanding analytical tasks in biomedical engineering and quality control environments.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026