58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Agilent Technologies 7890A SSL with 5975C Inert XL EI/CI Mass Selective Detector GC/MS System with Autosampler and Pfeiffer Duo 2.5 Roughing Pump

UsedAgilentGC systemsUnited States

Price on request

In stock

Can't find what you're looking for?

Description
Model 7890A GC System with model 5975C inert XL EI/CI MSD. Manufactured: USA. Voltage, frequency, power consumption, fuse rating, and software version are not visible. Includes Pfeiffer Duo 2.5 roughing pump with max 2.9 m³/h pumping speed and max 3600 1/min speed. The GC system serial number is CN10750037. The autosampler model is G2614A, serial CN74446040 and G2913A (serial CN80546848). MSD G3174A (serial US80148348).
Technical Data
Model: 7890A GC System with 5975C inert XL EI/CI MSD Serial Number: US80148348 Voltage: 230V Frequency: 60Hz Power Consumption: N/A Fuse Rating: N/A Software Version: N/A Configuration: Agilent 7890A GC System (Model G3440A, Serial CN10750037), Agilent 5975C inert XL EI/CI Mass Selective Detector (Model G3174A, Serial US80148348), Agilent 7683 Autosampler (Model G2614A, Serial CN74446040), G2913A (Serial CN80546848), Pfeiffer Vacuum Duo 2.5 Roughing Pump (Model PK D41 064 D, Serial 21283260) Manufacturing Year: N/A
Voltage
230V
Frequency
60Hz
Power Consumption
N/A
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Agilent
New/Used
Used
Description
Model 7890A GC System with model 5975C inert XL EI/CI MSD. Manufactured: USA. Voltage, frequency, power consumption, fuse rating, and software version are not visible. Includes Pfeiffer Duo 2.5 roughing pump with max 2.9 m³/h pumping speed and max 3600 1/min speed. The GC system serial number is CN10750037. The autosampler model is G2614A, serial CN74446040 and G2913A (serial CN80546848). MSD G3174A (serial US80148348).
Technical Data
Model: 7890A GC System with 5975C inert XL EI/CI MSD Serial Number: US80148348 Voltage: 230V Frequency: 60Hz Power Consumption: N/A Fuse Rating: N/A Software Version: N/A Configuration: Agilent 7890A GC System (Model G3440A, Serial CN10750037), Agilent 5975C inert XL EI/CI Mass Selective Detector (Model G3174A, Serial US80148348), Agilent 7683 Autosampler (Model G2614A, Serial CN74446040), G2913A (Serial CN80546848), Pfeiffer Vacuum Duo 2.5 Roughing Pump (Model PK D41 064 D, Serial 21283260) Manufacturing Year: N/A
Voltage
230V
Frequency
60Hz
Power Consumption
N/A
Fuse Rating
N/A
Software Version
N/A
Configuration
Agilent 7890A GC System (Model G3440A, Serial CN10750037), Agilent 5975C inert XL EI/CI Mass Selective Detector (Model G3174A, Serial US80148348), Agilent 7683 Autosampler (Model G2614A, Serial CN74446040), G2913A (Serial CN80546848), Pfeiffer Vacuum Duo 2.5 Roughing Pump (Model PK D41 064 D, Serial 21283260)
Manufacturing Year
N/A
Accessories
Autosampler G2614A, Pfeiffer Duo 2.5 Roughing Pump, Additional module G2913A
Dimensions
N/A
Weight
N/

Product description

Agilent 7890A GC/MS with 5975C inert XL EI/CI detector, autosampler, and roughing pump for advanced analytical workflows.

The Agilent Technologies 7890A SSL coupled with the 5975C Inert XL EI/CI Mass Selective Detector is a sophisticated gas chromatography-mass spectrometry (GC/MS) system designed for high-sensitivity molecular analysis. This configuration integrates:

  • 7890A GC System (Model G3440A, Serial CN10750037) providing precise gas chromatographic separation essential for complex biochemical and environmental sample analysis.
  • 5975C Inert XL EI/CI MSD (Model G3174A, Serial US80148348) offering electron ionization (EI) and chemical ionization (CI) modes for versatile mass spectrometric detection with enhanced inertness to reduce sample degradation and improve durability.
  • 7683 Autosampler (Models G2614A & G2913A) enabling automated, reproducible sample introduction crucial for high-throughput and consistent bioprocessing or synthetic biology workflows.
  • Pfeiffer Vacuum Duo 2.5 Roughing Pump (Model PK D41 064 D) with a maximum pumping speed of 2.9 m³/h at 3600 rpm, providing essential vacuum conditions that maintain MS detector performance and system stability during extended analytical runs.

This GC/MS system is widely adopted in molecular diagnostics, biomanufacturing, and analytical biotechnology research for applications such as molecular cloning validation, bioprocess monitoring, and environmental toxin analysis. The inert XL technology is critical for reducing active site interaction within the ion source, enhancing the reliability of trace-level compound detection in synthetic biology and clinical diagnostic pipelines.

Primary keywords such as gas chromatograph, mass selective detector, and GC/MS system are incorporated to reflect core functionalities, while long-tail phrases like essential for molecular cloning workflows and critical in biopharmaceutical production pipelines support its biotechnological relevance. This configuration offers robust integration of chromatography, mass spectrometry, automated sampling, and vacuum generation optimized for advanced analytical and research laboratories.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026