Agilent Technologies 5973N Mass Selective Detector and 6850A Gas Chromatograph GC/MS System

UsedAgilentGC systemsUnited States

Price on request

In stock

Can't find what you're looking for?

Description
Model: 5973N MSD and 6850A GC. Serial Numbers: MSD US43146983, GC US10607009, Autosampler CN21720241, Pump E2M261749. Voltage: 230 Vac ±10%. Frequency: 47.5-63 Hz. Power consumption: 2000 VA max. Fuse rating: N/A. Software version: N/A. Manufactured: N/A.
Technical Data
Model: 5973N MSD / 6850A GC Serial Number: MSD US43146983 / GC US10607009 / ALS CN21720241 / PUMP E2M261749 Voltage: 230 Vac ±10% Frequency: 47.5-63 Hz Power Consumption: 2000 VA max Fuse Rating: N/A Software Version: N/A Configuration: 5973N Mass Selective Detector (MSD), 6850A Gas Chromatograph (GC), Autosampler G2880A with Option T27-2ml, Edwards E2M2 High Vacuum Pump Manufacturing Year: N/A
Voltage
230 Vac ±10%
Frequency
47.5-63 Hz
Power Consumption
2000 VA max
All 14 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 14

Brands
Agilent
New/Used
Used
Description
Model: 5973N MSD and 6850A GC. Serial Numbers: MSD US43146983, GC US10607009, Autosampler CN21720241, Pump E2M261749. Voltage: 230 Vac ±10%. Frequency: 47.5-63 Hz. Power consumption: 2000 VA max. Fuse rating: N/A. Software version: N/A. Manufactured: N/A.
Technical Data
Model: 5973N MSD / 6850A GC Serial Number: MSD US43146983 / GC US10607009 / ALS CN21720241 / PUMP E2M261749 Voltage: 230 Vac ±10% Frequency: 47.5-63 Hz Power Consumption: 2000 VA max Fuse Rating: N/A Software Version: N/A Configuration: 5973N Mass Selective Detector (MSD), 6850A Gas Chromatograph (GC), Autosampler G2880A with Option T27-2ml, Edwards E2M2 High Vacuum Pump Manufacturing Year: N/A
Voltage
230 Vac ±10%
Frequency
47.5-63 Hz
Power Consumption
2000 VA max
Fuse Rating
N/A
Software Version
N/A
Configuration
5973N Mass Selective Detector (MSD), 6850A Gas Chromatograph (GC), Autosampler G2880A with Option T27-2ml, Edwards E2M2 High Vacuum Pump
Manufacturing Year
N/A
Accessories
Autosampler G2880A with Option T27-2ml, Edwards E2M2 High Vacuum Pump
Dimensions
N/A
Weight
N/A

Product description

Combined Agilent 5973N MSD and 6850A GC with autosampler and vacuum pump for precise chemical analysis.

The Agilent Technologies 5973N MSD and 6850A GC constitute a high-performance gas chromatography-mass spectrometry (GC/MS) system widely used in molecular diagnostics, synthetic biology, and bioprocessing. This configuration includes:

  • 5973N Mass Selective Detector (MSD) enabling sensitive mass spectrometric detection critical for chemical compound identification and quantification.
  • 6850A Gas Chromatograph (GC) providing precise chromatographic separation essential for biopharmaceutical production pipelines and environmental monitoring.
  • Autosampler G2880A with Option T27-2ml, enhancing sample throughput and reproducibility in gene editing workflows and metabolic profiling studies.
  • Edwards E2M2 High Vacuum Pump, ensuring optimal vacuum conditions for reliable mass spectrometer operation.

Technical specifications:

  • Voltage: 230 Vac ±10%
  • Frequency: 47.5–63 Hz
  • Power consumption: 2000 VA max
  • Serial Numbers: MSD US43146983, GC US10607009, Autosampler CN21720241, Pump E2M261749

This GC/MS system is critical for advanced laboratory applications including biotechnology research, synthetic biology analysis, molecular cloning verification, and complex chemical profiling. It is widely adopted in clinical diagnostics and neuroscience research where high sensitivity and specificity in chemical analysis are paramount. The integrated autosampler supports high-throughput workflows, essential for biomanufacturing quality control and fluorescence analysis applications.

Overall, the Agilent 5973N/6850A GC/MS system delivers robust performance for comprehensive chemical characterization, making it an indispensable instrument in biomedical engineering and molecular biology laboratories focused on bioprocessing and molecular diagnostics.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026