51k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Yamato INE-800 Refrigerated Forced Convection Eco Incubator (115V)

From€12,713.25excl. VAT

In stock

Can't find what you're looking for?

System
Forced convection
Operating Temperature Range
0~+60°C
Setting Temperature Range
-5~+65°C
Temperature Adjustment Accuracy
±0.2°C (at 37°C during continuous operation), ±0.5°C (at 37°C cycle operation)
Temperature Fluctuation
±0.3°C (at 37°C during continuous operation), ±1.0°C (at 37°C cycle operation)
All 36 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 36

Brands
Yamato Scientific
New/Used
Used
System
Forced convection
Operating Temperature Range
0~+60°C
Setting Temperature Range
-5~+65°C
Temperature Adjustment Accuracy
±0.2°C (at 37°C during continuous operation), ±0.5°C (at 37°C cycle operation)
Temperature Fluctuation
±0.3°C (at 37°C during continuous operation), ±1.0°C (at 37°C cycle operation)
Temp. Distribution Accuracy
±0.5°C (at 37°C during continuous operation)
Temperature Gradient
2.0°C (at 37°C during continuous operation)
Max. Temperature Reaching Time
20~60°C 35min.
Min. Temperature Reaching Time
20~0°C 50min.
Cooling Mechanism
Continuous operation, Cycle operation, Cooling-stop operation
Interior
Stainless steel
Exterior
Chromate-free electrogalvanized steel plate Baked chemical resistant finish
Heat Insulator
Styrene foam (non-freon)
Freezer
200W Rotary Unit
Cooling Medium
R134a 350g
Operation Range Of Freezer
Below 40°C
Defrosting Mechanism
Hot Gas Bypass Method, Manual (random) Defrost / Auto (time) Defrost
Blower Fan
DC Axial flow fan 4-Step, Equipped with Error Signal when stopped
Heater
Iron-chrome wire heater : 750W
Sensor
Double sensor: Platinum resistance temperature detector: Pt100Ω (temperature controller), K-thermocouple (overheat prevention device)
Cable Port
I.D.: 50 mm (right side of main unit)
Temperature Controller
PID control by microprocesser
Temperature Display
Setting Temp. Display : 5-digit orange LED digital display / Actual Temp. Display : 4-digit green LED digital display
Timer / Timer Resolution
0~99hr. 59min. / 1min.
Operation Function
Fixed temperature, Auto start, Auto stop, Quick auto stop, Program (99 steps, 99 patterns)
Additional Functions
Timer, Calibration off-set, Electricity & CO₂ Emission Monitor, Voltage Recovery Optional, User Setting saving/readout, Calendar timer (24 hours)
Safety Device
Self diagnostic function (temp. sensor error, heater disconnection, SSR short-circuit, main relay error, automatic overheat prevention), Key lock, Overcurrent electric leakage breaker, Overheat prevention device, Fan malfunction detector, Cooling high-pressure detector, Inverter malfunction detector
External Dimensions WxDxH
710 x 645 x 1730 mm
Internal Dimensions WxDxH
600 x 477 x 1000 (effective 800) mm
Internal Capacity
286L
Shelf Load Capacity
15 kg/pc.
Shelf Rest Step Number / Pitch
23 steps / 30mm
Power Supply (50/60 Hz)
AC115V 8.7A (with plug)
Weight
~135kg

Product description

Programmable refrigerated forced convection incubator, 286L capacity, ±0.2°C accuracy, energy efficient with inverter control.

Yamato INE-800 Refrigerated Forced Convection Eco Incubator (115V)

  • Capacity: 286 L
  • System: Forced convection
  • Operating Temperature Range: 0 to +60°C
  • Setting Temperature Range: -5 to +65°C
  • Temperature Accuracy: ±0.2°C (at 37°C continuous), ±0.5°C (at 37°C cycle)
  • Temperature Fluctuation: ±0.3°C (continuous), ±1.0°C (cycle)
  • Temperature Distribution Accuracy: ±0.5°C (continuous)
  • Temperature Gradient: 2.0°C (continuous)
  • Heating Time: 20 to 60°C in 35 min
  • Cooling Time: 20 to 0°C in 50 min
  • Cooling Modes: Continuous, cycle, cooling-stop
  • Interior: Stainless steel
  • Exterior: Chromate-free electrogalvanized steel with chemical-resistant finish
  • Insulation: Styrene foam (non-freon)
  • Freezing Unit: 200W rotary compressor with R134a refrigerant (350g)
  • Defrosting: Hot gas bypass, manual and automatic time-based defrost
  • Air Circulation: DC axial flow fan, 4-speed with error detection
  • Heater: Iron-chrome wire, 750W
  • Sensors: Dual sensor system - Pt100 platinum resistance for control, K-thermocouple for overheat prevention
  • Controller: Microprocessor PID control
  • Display:
  • Set temperature: 5-digit orange LED
  • Actual temperature: 4-digit green LED
  • Timer: 0 to 99 hr 59 min resolution 1 min
  • Operation Modes: Fixed temperature, auto start/stop, quick auto stop, programmable (up to 99 steps and patterns)
  • Additional Functions: Calibration offset, electricity and CO₂ emission monitor, user data save/read, calendar timer, voltage recovery optional
  • Safety Features:
  • Self-diagnostics (sensor error, heater/fan failures, SSR short circuit, relay error)
  • Key lock
  • Overcurrent leakage breaker
  • Overheat prevention device
  • Cooling high-pressure detector
  • Inverter malfunction detector
  • Dimensions (WxDxH): External 710 x 645 x 1730 mm; Internal 600 x 477 x 1000 mm (effective 800 mm height)
  • Shelf Capacity: 15 kg per shelf, 5 stainless steel punched metal shelves included, with 10 brackets
  • Cable Port: 50 mm diameter on right side
  • Power Supply: AC 115V, 8.7A (with plug)
  • Weight: Approx. 135 kg
  • Included Accessories: 5 stainless steel shelves, 10 brackets, 2 keys, silicon stopper for cable hole

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour