System
Forced air convection
Operating Temperature Range
-10°C~+50°C
Temperature Adjustment Accuracy
±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation)
Temp. Distribution Accuracy
±1.0°C (refrigerator in continuous operation at 37°C)
Max. Temp. Reaching Time
Data unavailable
All 35 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 35

Brands
Yamato Scientific
New/Used
Used
System
Forced air convection
Operating Temperature Range
-10°C~+50°C
Temperature Adjustment Accuracy
±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation)
Temp. Distribution Accuracy
±1.0°C (refrigerator in continuous operation at 37°C)
Max. Temp. Reaching Time
Data unavailable
Minimum Temp. Reaching Time
Data unavailable
Interior Material
Stainless steel
Exterior Material
Chrome free electronic galvanized plated steel plate chemical proof baking finish
Observation Window
Data unavailable
Heat Insulation Material
Styrene foam
Refrigerator
Air-cooled fully closed compressor 300W
Refrigerator Medium
R404A
Defrosting Mechanism
Manual ON / Auto OFF, Timer operation, Cycle operation
Blower Fan
Axial fan
Heater
Iron-chrome wire heater: 750W
Sensor
Platinum resistance temperature detector: Pt100Ω (temp. controller), K-thermocouple (overheat prevention device)
Cable Port (Right Side)
I.D.: 30 mm
Temperature Control
PID control
Temperature Setting
Digital setting with ▲▼ keys
Temperature Display
Measured temperature: 4-digit orange LED digital display + VFD fluorescent display
Timer / Timer Resolution
0 min. ~ 999 hrs. 59 min. / 1 min.
Operation Function
Fixed temperature, auto stop, auto start, program (up to 32 steps, repeat operation)
Additional Functions
Timer function (accumulated time to 49,999 hrs), calibration off-set function, clock display
Safety Device
Self diagnostic function (Temp. sensor error, Heater disconnection, SSR short-circuit, Main relay error, Automatic overheat prevention function), Key lock, Over current ELB, Overheat prevention device
Internal Dimensions W X D X H
600 x 477 x 1000 mm
External Dimensions W X D X H
710 x 645 x 1630 mm
Internal Capacity
286L
Shelf Plate Load
15kg / pc.
Shelf Rest Step Number / Pitch
23 steps / 30mm
Power Supply (50/60Hz)
AC115V (with plug)AC220V (no plug, round terminal)
Weight
~ 120kg
Door Keys
2 keys
Optional Items
Stand, additional shelf, cable port (ø30/50mm), recorder, warning light combination (stand-by/operation/error), observation window, temperature output terminal (4-20mA), external alarm output terminal, time up output terminal

Product description

Programmable refrigerated incubator with forced convection, PID control, ±0.3°C accuracy, -10°C to 50°C range, 286L capacity.

Yamato IN Series Programmable Refrigerated Forced Convection Incubator IN-804W-220V

Standard low temperature forced convection incubator for environmental and low temperature testing.

Operation and Functions:

  • High accuracy temperature control and uniform distribution
  • Large dual glass door with inner glass for stable temperature and improved heat retention (triplex glass door)
  • Interior lighting for sample visibility
  • Optional slide shaker table for easy sample handling

Specifications:

  • System: Forced air convection
  • Operating Temperature Range: -10°C to +50°C
  • Temperature Adjustment Accuracy: ±0.3°C (continuous refrigeration), ±1.0°C (cycle refrigeration)
  • Temperature Distribution Accuracy: ±1.0°C at 37°C (continuous refrigeration)
  • Interior Material: Stainless steel
  • Exterior Material: Chrome-free electronic galvanized steel with chemical-proof baking finish
  • Heat Insulation: Styrene foam
  • Refrigerator: Air-cooled fully closed compressor, 300W
  • Refrigerant: R404A
  • Defrosting: Manual ON / Auto OFF, Timer operation, Cycle operation
  • Blower Fan: Axial fan
  • Heater: Iron-chrome wire, 750W
  • Sensors: Pt100Ω platinum resistance temperature detector (controller), K-thermocouple (overheat prevention)
  • Temperature Control: PID control, digital setting via ▲▼ keys
  • Display: 4-digit orange LED + VFD fluorescent
  • Timer: 0 min to 999 hrs 59 min, 1 min resolution
  • Operation Modes: Fixed temperature, auto stop/start, programmable (up to 32 steps, repeatable)
  • Additional Functions: Timer (accumulated time to 49,999 hrs), calibration offset, clock display
  • Safety Features: Self-diagnostics, key lock, overcurrent ELB, overheat prevention with sensors
  • Dimensions (WxDxH): Internal 600 x 477 x 1000 mm; External 710 x 645 x 1630 mm
  • Internal Capacity: 286 liters
  • Shelf Load Capacity: 15 kg per shelf
  • Shelf Adjustment: 23 steps with 30 mm pitch
  • Power Supply: AC115V (with plug), AC220V (no plug, round terminal)
  • Weight: Approximately 120 kg
  • Included Accessories: 5 shelves, 10 shelf brackets, 2 door keys

Optional Accessories:

  • Stand
  • Additional shelves
  • Cable ports (ø30/50 mm)
  • Recorder
  • Warning light combinations (stand-by/operation/error)
  • Observation window
  • Temperature output terminal (4-20 mA)
  • External alarm output terminal
  • Time up output terminal

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026