System
Forced air convection
Operating Temperature Range
-10°C~+50°C
Temperature Adjustment Accuracy
±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation)
Temp. Distribution Accuracy
±1.0°C (refrigerator in continuous operation at 37°C)
Max. Temp. Reaching Time
20~50°C ~20min
All 35 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 35

Brands
Yamato Scientific
New/Used
Used
System
Forced air convection
Operating Temperature Range
-10°C~+50°C
Temperature Adjustment Accuracy
±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation)
Temp. Distribution Accuracy
±1.0°C (refrigerator in continuous operation at 37°C)
Max. Temp. Reaching Time
20~50°C ~20min
Minimum Temp. Reaching Time
20~-10°C ~55min
Interior Material
Stainless steel
Exterior Material
Chrome free electronic galvanized plated steel plate chemical proof baking finish
Observation Window
W516 x H416mm (with key)
Heat Insulation Material
Styrene foam
Refrigerator
Air-cooled fully closed compressor 250W
Refrigerator Medium
R134A
Defrosting Mechanism
Manual ON / Auto OFF, Timer operation, Cycle operation
Blower Fan
Axial fan
Heater
Iron-chrome wire heater: 550W
Sensor
Platinum resistance temperature detector: Pt100Ω (temp. controller), K-thermocouple (overheat prevention device)
Cable Port (Right Side)
I.D.: 50 mm
Temperature Control
PID control
Temperature Setting
Digital setting with ▲▼ keys
Temperature Display
Measured temperature: 4-digit orange LED digital display + VFD fluorescent display
Timer / Timer Resolution
0 min. ~ 999 hrs. 59 min. / 1 min.
Operation Function
Fixed temperature, auto stop, auto start, program (up to 32 steps, repeat operation)
Additional Functions
Timer function (accumulated time to 49,999 hrs), calibration off-set function, clock display
Safety Device
Self diagnostic function (Temp. sensor error, Heater disconnection, SSR short-circuit, Main relay error, Automatic overheat prevention function), Key lock, Over current ELB, Overheat prevention device
Internal Dimensions W X D X H
600 x 477 x 500 mm
External Dimensions W X D X H
710 x 645 x 913 mm
Internal Capacity
143L
Shelf Plate Load
15kg / pc.
Shelf Rest Step Number / Pitch
13 steps / 30mm
Power Supply (50/60Hz)
AC115V 10.5A (with plug)AC220V 7.5A (no plug, round terminal)
Weight
~89kg
Door Keys
2 keys
Optional Items
Stand, additional shelf, cable port (ø30/50mm), recorder, warning light combination (stand-by/operation/error), observation window, temperature output terminal (4-20mA), external alarm output terminal, time up output terminal

Product description

Programmable refrigerated forced convection incubator with ±0.3°C accuracy, triplex glass door, and 143L capacity.

  • Operation and Functions:
  • High accuracy temperature control and uniform temperature distribution
  • Triplex glass door system (large dual glass door + inner door) for improved heat retention (model IN-604W)
  • Inner glass door maintains temperature during observation
  • Interior light for sample visibility
  • Optional slide shaker table available for easy sample handling
  • Technical Specifications:
  • System: Forced air convection
  • Operating Temperature Range: -10°C to +50°C
  • Temperature Adjustment Accuracy: ±0.3°C (continuous operation), ±1.0°C (cycled operation)
  • Temperature Distribution Accuracy: ±1.0°C at 37°C (continuous operation)
  • Max Temperature Reach Time (20→50°C): ~20 min
  • Min Temperature Reach Time (20→-10°C): ~55 min
  • Interior: Stainless steel
  • Exterior: Chrome free electronic galvanized plated steel with chemical-resistant baking finish
  • Observation Window: 516 mm (W) x 416 mm (H) with key
  • Insulation: Styrene foam
  • Refrigerator: Air-cooled fully enclosed 250W compressor
  • Refrigerator Medium: R134A
  • Defrosting: Manual ON / Auto OFF, timer and cycle operation
  • Blower Fan: Axial fan
  • Heater: 550W iron-chrome wire heater
  • Sensors: Pt100Ω platinum resistance temperature detector for control; K-thermocouple for overheat prevention
  • Cable Port (right side): 50 mm inner diameter
  • Temperature Control: PID control with digital setting, ▲▼ keys
  • Display: 4-digit orange LED + VFD fluorescent for measured temperature
  • Timer: 0 min to 999 hrs 59 min resolution 1 min, programs up to 32 steps with repeat
  • Additional Functions: Accumulated timer up to 49,999 hrs, calibration offset, clock display
  • Safety Devices: Self-diagnostics (sensor error, heater disconnection, SSR short-circuit, relay error), key lock, overcurrent ELB, overheat prevention
  • Internal Dimensions (W x D x H): 600 x 477 x 500 mm
  • External Dimensions (W x D x H): 710 x 645 x 913 mm
  • Internal Capacity: 143 liters
  • Shelf Load Capacity: 15 kg per shelf
  • Shelf Steps: 13 steps with 30 mm pitch
  • Power Supply: AC115V 10.5A (plug), AC220V 7.5A (no plug)
  • Weight: Approximately 89 kg
  • Included Accessories: 3 stainless steel shelves, 6 shelf brackets, 2 door keys
  • Optional Items: Stand, additional shelves, cable ports (ø30/50 mm), recorder, warning light combinations, observation window, temperature output (4-20 mA), external alarm and time-up output terminals

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026