58k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Yamato IN-604 Forced Convection Refrigerated Incubator 220V, 143L Capacity

From€4,571.83excl. VAT

In stock

Can't find what you're looking for?

System
Forced air convection
Operating Temperature Range
-10°C~+50°C
Temperature Adjustment Accuracy
±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation)
Temp. Distribution Accuracy
±1.0°C (refrigerator in continuous operation at 37°C)
Max. Temp. Reaching Time
20~50°C ~20min
All 36 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 36

Brands
Yamato Scientific
New/Used
Used
System
Forced air convection
Operating Temperature Range
-10°C~+50°C
Temperature Adjustment Accuracy
±0.3°C (refrigerator in continuous operation) / ±1.0°C (refrigerator in cycle operation)
Temp. Distribution Accuracy
±1.0°C (refrigerator in continuous operation at 37°C)
Max. Temp. Reaching Time
20~50°C ~20min
Minimum Temp. Reaching Time
20~-10°C ~ 45min
Interior Material
Stainless steel
Exterior Material
Chrome free electronic galvanized plated steel plate chemical proof baking finish
Observation Window
---
Heat Insulation Material
Styrene foam
Refrigerator
Air-cooled fully closed compressor 250W
Refrigerator Medium
R134A
Defrosting Mechanism
Manual ON / Auto OFF, Timer operation, Cycle operation
Blower Fan
Axial fan
Heater
Iron-chrome wire heater: 550W
Sensor
Platinum resistance temperature detector: Pt100Ω (temp. controller), K-thermocouple (overheat prevention device)
Cable Port (Right Side)
I.D.: 32 mm
Temperature Control
PID control
Temperature Setting
Digital setting with ▲▼ keys
Temperature Display
Measured temperature: 4-digit orange LED digital display + VFD fluorescent display
Timer / Timer Resolution
0 min. ~ 999 hrs. 59 min. / 1 min.
Operation Function
Fixed temperature, auto stop, auto start, program (up to 32 steps, repeat operation)
Additional Functions
Timer function (accumulated time to 49,999 hrs), calibration off-set function, clock display
Safety Device
Self diagnostic function (Temp. sensor error, Heater disconnection, SSR short-circuit, Main relay error, Automatic overheat prevention function), Key lock, Over current ELB, Overheat prevention device
Internal Dimensions W X D X H
600 x 477 x 500 mm
External Dimensions W X D X H
710 x 645 x 913 mm
Internal Capacity
143L
Shelf Plate Load
15kg / pc.
Shelf Rest Step Number / Pitch
13 steps / 30mm
Power Supply (50/60Hz)
AC115V 9A (with plug) AC220V 5.5A (no plug, round terminal)
Weight
~89kg
Shelf / Shelf Brackets
3 pcs. / 6 pcs. stainless steel punched metal
Door Keys
---
Optional Items
Stand, additional shelf, cable port (ø30/50mm), recorder, warning light combination (stand-by/operation/error), observation window, external communication function (RS485), temperature output terminal (4-20mA), external alarm output terminal, time up output terminal

Product description

Forced convection refrigerated incubator with precise PID control, -10°C to 50°C range, 143L capacity, and stainless steel interior.

Yamato IN-604 Forced Convection Refrigerated Incubator operates at 220V with a 143L internal capacity. Designed for low temperature and environmental testing, it features:

  • Temperature Control: PID control with digital setting, ±0.3°C accuracy (continuous refrigeration), ±1.0°C (cycled refrigeration)
  • Operating Range: -10°C to +50°C
  • Temperature Distribution: ±1.0°C at 37°C (continuous operation)
  • Heating & Cooling: Iron-chrome wire heater (550W) and air-cooled fully closed compressor (250W, refrigerant R134A)
  • Defrosting: Manual ON / Auto OFF, Timer or Cycle operation
  • Structure: Stainless steel interior; chrome-free electronic galvanized steel exterior with chemical-proof baking finish
  • Doors: Large dual glass door with inner glass door forming a triplex configuration (model variants IN604W/804W feature additional interior lighting)
  • Safety Features: Self-diagnostic system (sensor errors, heater faults, SSR short-circuit, relay errors), key lock, overcurrent ELB, overheat prevention
  • Dimensions (Internal W x D x H): 600 x 477 x 500 mm
  • Dimensions (External W x D x H): 710 x 645 x 913 mm
  • Weight: Approximately 89 kg
  • Shelves: 3 stainless steel punched metal shelves, each supporting up to 15 kg, with 13 adjustable height positions (30 mm pitch)
  • Display & Timer: 4-digit orange LED and VFD fluorescent display; timer range 0 min to 999 hrs 59 min with 1 min resolution
  • Additional Functions: Fixed temperature, auto stop/start, programmable steps (up to 32 steps, repeat mode), calibration offset, clock display, timer accumulation up to 49,999 hrs
  • Optional Accessories: Stand, extra shelves, cable ports (30/50 mm), recorder, warning light system, observation window, RS485 communication, temperature output (4-20 mA), external alarm and time-up output terminals

This incubator provides stable temperature control and ease of sample observation, suitable for research requiring controlled low temperature environments.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Yes. Every verified supplier states which service partners cover the instrument, and we list that alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 19 October 2026