52k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Thermo Scientific Heracell VIOS 160i 165L CO2 Incubator with 180°C Dry-Heat Decontamination

Price on request

In stock

Can't find what you're looking for?

Capacity
5.8 cu. ft., 165L per unit
Dimensions Interior
18x20x24” per unit
Chamber/ Shelf Material
Stainless or Copper (51030410)
Disinfection Time
Under 12 Hours
CO2 Concentration Range
1 to 20%
All 17 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 17

Brands
Thermo Fisher Scientific
New/Used
Used
Capacity
5.8 cu. ft., 165L per unit
Dimensions Interior
18x20x24” per unit
Chamber/ Shelf Material
Stainless or Copper (51030410)
Disinfection Time
Under 12 Hours
CO2 Concentration Range
1 to 20%
O2 Concentration Range (TriGas Model Only)
1 to 21%
CO2 Sensor Technology
TC Sensor (51033547 ) or IR Sensor (51030400, 51033557, 51030410)
Humidity Delivery
Integral Reservoir
Relative Humidity
< 93% @ 37°C
Temperature Range (Metric)
Ambient +3° to 55°C
Data Outputs
USB, and optional 4-20mA
Probes
Dual temperature probes for over-temperature protection with operational backup
Dimensions Exterior
25x39x36” per unit
Weight
183 lbs
Power
120V, 50/60Hz, 8.3 , 1.0kW

Product description

165L CO2 incubator with THRIVE airflow, 1–20% CO2 control, 180°C dry-heat sterilization, ideal for cell culture.

The Thermo Scientific Heracell VIOS 160i is a state-of-the-art CO2 incubator featuring a 165 L (5.8 cu. ft.) capacity engineered for precise environmental control essential in cell culture and biotechnology applications. Key technical specifications include:

  • CO2 Concentration Range: 1–20%, regulated via either thermal conductivity (TC) or infrared (IR) sensor technology, supporting robust molecular diagnostics and gene editing workflows.
  • Temperature Control: Operates from ambient +3 °C up to 55 °C to accommodate diverse incubation protocols in synthetic biology and bioprocessing.
  • Humidity Management: Maintains <93% relative humidity at 37 °C through pre-humidified gas delivery and an internal integral water reservoir, crucial for live-cell imaging and tissue engineering.
  • Chamber Design: Available in polished stainless steel or copper interior with passive antimicrobial properties to reduce contamination risks in molecular cloning and biomanufacturing pipelines. Coved interior corners facilitate continuous airflow.
  • THRIVE Active Airflow System: Ensures uniform temperature, CO2, and humidity distribution across all shelf positions, minimizing environmental gradients for reproducible cell culture results.
  • Dry-Heat Decontamination Cycle: Automated 180 °C sterilization completes under 12 hours without disassembly, ideal for maintaining aseptic conditions required in clinical diagnostics.
  • HEPA Filtration: ISO Class 5 HEPA filter continuously recirculates and cleans chamber air to lower particulate and microbial contamination during extended incubation runs.
  • User Interface: iCAN touchscreen allows access to alarm status, system parameters, and operating trends; integrated USB data logging and optional 4–20 mA analog outputs enable connection to facility management systems.
  • Safety Features: Dual temperature probes provide over-temperature protection with operational backup, ensuring critical safeguards for sensitive cell culture workflows.
  • Dimensions and Power: Exterior: 25”W x 39”D x 36”H; Weight: 183 lbs; Power: 120V, 50/60Hz, 1.0 kW.

Widely adopted in biotechnology laboratories, this incubator supports molecular diagnostics, synthetic biology research, bioprocess development, and clinical cell culture applications. Its precise environmental controls and advanced contamination prevention technologies make it essential for maintaining sterile conditions in biopharmaceutical production pipelines and live-cell experimentation. The double-stack cabinet design offers scalable incubation capacity within a limited laboratory footprint.

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 8 November 2026