53k+ listingsShips to NLResponse within one hour+31 73 711 4717info@questpair.com

Memmert IPP110ecoplus Peltier-Cooled Forced Circulation Incubator 108L, 115V

NewMemmertIncubatorsUnited States

From€7,670.55excl. VAT

In stock

Can't find what you're looking for?

Volume
108 L (3.8 cu.ft.)
Setting Temperature Range
0 to +70°C
Working Temperature Range
Without light: from 0°C (at least 20°C below ambient) to +70°C
Setting Accuracy
0.1°C
Temperature Sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
All 27 specifications
  • Ships to NL
  • Response within 1 hour
  • Warranty available. Buy without worry
  • Support from a scientist

Specifications 27

Brands
Memmert
New/Used
New
Volume
108 L (3.8 cu.ft.)
Setting Temperature Range
0 to +70°C
Working Temperature Range
Without light: from 0°C (at least 20°C below ambient) to +70°C
Setting Accuracy
0.1°C
Temperature Sensor
2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Temperature Control
Over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
Autodiagnostic System
For fault analysis
Control Panel
ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Timer
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT
Process time does not start until the set temperature is reached
AtmoCONTROL
AtmoCONTROL software on a USB stick for programming, managing and transferring programms
Calibration
Three freely selectable temperature values
Adjustable Parameters
Temperature (Celsius or Fahrenheit), programme time, time zones, summertime/wintertime
Communication Interfaces
Ethernet LAN, USB
Convection
Forced ventilation by Peltier fan
Heating Concept
Peltier energy-saving heating/cooling system integrated in the rear (heat pump principle)
Humidity
Max. 70%, non-condensing
Shelving
2 stainless steel wire shelves
Max. Number of Shelves
5
Max. Loading of Chamber
330 lbs (150 kg)
Max. Loading Per Shelf
44 lbs (20 kg)
Interior Dimensions (WxHxD)
22” x 18.9” x 15.8” (56 x 48 x 40 cm)
Exterior Dimensions (WxHxD)
29.3” x 34” x 23” (74.5 x 86.4 x 58.4 cm)
Weight
172 lbs (78 kg)
Electrical Load
115 V, 50/60 Hz, approx. 320 W

Product description

108L Peltier-cooled incubator for efficient temperature control.

Memmert IPP110ecoplus Peltier-Cooled Forced Circulation Incubator 108L, 115V

Setting Temperature Range Ambient 0°C to 70°C Convection Type Peltier Fan Forced Circulation Chamber Volume 108 L (3.8 cu.ft.)

Features

  • 108 L volume capacity with precise temperature control
  • Working temperature range from 0°C (at least 20°C below ambient) to +70°C
  • Energy-saving Peltier heating/cooling system with individually controlled upper and lower elements
  • ControlCOCKPIT with TwinDISPLAY and adaptive multifunctional digital PID-microprocessor controller
  • Process timing starts only when the set temperature is reached with the SetpointWAIT function
  • Three freely selectable temperature calibration points for accurate control
  • Over- and undertemperature monitor with AutoSAFETY protection for enhanced safety
  • Durable stainless steel interior and textured stainless steel exterior for corrosion resistance and easy cleaning

The Memmert IPP110ecoplus Peltier-Cooled Forced Circulation Incubator 108L, 115V delivers precise, energy-efficient temperature control for advanced laboratory applications. With a generous 108-liter capacity and a working temperature range from 0°C (at least 20°C below ambient) to +70°C, this incubator supports a variety of sample requirements. The energy-saving Peltier heating and cooling system, featuring individually controlled upper and lower elements, ensures uniform and reliable temperature distribution. The intuitive ControlCOCKPIT with TwinDISPLAY, equipped with a PID-microprocessor controller and high-definition TFT displays, provides easy monitoring, while the SetpointWAIT function enhances accuracy by starting process timing only once the desired temperature is reached.

This incubator’s robust stainless steel interior and textured exterior resist corrosion and allow for easy maintenance, ideal for long-term use in demanding environments. Safety features include an AutoSAFETY over- and undertemperature monitor with both visual and acoustic alarms, ensuring protection for sensitive samples. Additional features, such as three customizable temperature calibration points, an autodiagnostic system for fault detection, and a capacity for up to five shelves with a maximum chamber load of 330 lbs, make the IPP110ecoplus a versatile and reliable choice for modern labs.

INCLUDED: The Memmert IPP110ecoplus Peltier-Cooled Forced Circulation Incubator 108L, 115V includes:

  • 2 Stainless Steel Grids
  • Tilt Protection Wall Bracket
  • Calibration Certificate
  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 3 Year Manufacturer's Warranty

Why Questpair exists

Lab equipment markets are fragmented. Buyers spend weeks calling distributors, comparing quotes, and verifying supplier reliability. Sellers struggle to reach global research labs.

We built Questpair to fix this. Every supplier on the platform is verified before listing. Every quote you receive comes from a real, vetted seller. AI prepares your case in minutes, then a real specialist takes over.

We're an independent team based in The Netherlands, working with research labs and procurement teams across Europe and worldwide.

Frequently asked questions

How long does laboratory equipment typically last?

With a service contract, ten to fifteen years is normal for most benchtop instruments. Detectors and pumps are the parts that wear first.

Can I get service for older equipment?

Often, yes. Verified suppliers frequently work with service partners converting the instrument. If applicable, we can list servicing options alongside the offer.

Where can I buy parts?

Ask a scientist through the request button. Parts are often available even when the instrument itself is discontinued.

What is the typical lead time for refurbished equipment?

Two to six weeks, depending on refurbishment scope and whether calibration is included.

Does laboratory equipment ship internationally?

We ship to 38 countries. Crating and customs handling are quoted with the instrument.

Reply in one hour

Can't find the exact configuration?

Tell us what you need and a scientist finds it for you, usually within the hour.

Last updated 3 November 2026